APPENDIX A BLOWER PERFORMANCE TABLES

DIRECT DRIVE

CPG060 DOWN SHOT

CPG060 DIRECT DRIVE DOWN SHOT

SPEED

EXTERNAL STATIC

STANDARD

 

 

 

PRESSURE (ESP)

AMPS

WATTS

RPM

TAP

CFM

in w.c.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.10

1237

1.64

180

638

 

0.20

1191

1.75

194

682

T1

0.30

1127

1.80

200

715

 

0.40

1065

1.89

214

753

 

0.50

994

1.97

220

797

 

0.10

1437

2.13

248

687

 

0.20

1384

2.24

254

726

T2

0.30

1312

2.29

262

759

 

0.40

1245

2.42

280

803

 

0.50

1185

2.54

294

847

 

0.10

1988

4.49

558

885

 

0.20

1942

4.58

574

907

 

0.30

1882

4.69

582

935

T3

0.40

1847

4.80

600

962

 

0.50

1784

4.87

612

990

 

0.60

1762

4.97

626

1008

 

0.70

1688

5.05

642

1039

 

0.10

2106

5.14

650

924

 

0.20

2050

5.26

670

951

 

0.30

1993

5.32

678

969

T4

0.40

1960

5.47

696

1001

0.50

1920

5.54

706

1021

 

0.60

1880

5.61

726

1041

 

0.70

1810

5.73

736

1072

 

0.80

1760

5.81

750

1093

 

0.90

1694

5.84

752

1122

 

0.10

2199

5.87

762

968

 

0.20

2146

5.96

772

989

 

0.30

2121

6.06

788

1012

 

0.40

2066

6.15

804

1039

T5

0.50

2010

6.21

814

1056

 

0.60

1978

6.32

834

1084

 

0.70

1919

6.28

830

1102

 

0.80

1837

6.22

814

1122

 

0.90

1738

6.04

786

1127

NOTES:

Tables represent dry coil without filter, to compensate for filter add 0.08" to measured E.S.P. SCFM correction for wet coil = 4 %. 5 Ton models are shipped from the factory with speed tap set on T4.