CPG036(048)0453B THREE PHASE 240V/60HZ BELT DRIVE

HIGH VOLTAGE!

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

 

 

 

SUPPLY VOLTAGE

 

 

L2

L3

 

 

 

 

 

208-240/3/60

 

 

 

 

 

 

C

T1

 

T2

T2

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

 

 

 

 

 

 

 

 

 

 

T3

 

T3

C

 

 

 

 

 

 

 

FC

 

 

 

 

 

 

 

 

 

CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BC

 

 

 

 

BC

EM

 

 

 

 

BC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

VMR VM

 

 

 

 

 

 

 

1

 

3

 

 

 

 

NOTE 3

 

 

 

 

TR

NOTE 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGN

BC

 

IIC

 

F

 

 

FS

 

 

FS

 

 

 

H

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

 

 

 

 

 

 

 

4

 

 

 

LS

 

VMR

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALS

 

RS

 

 

 

 

IIC

 

3

 

 

 

 

GV

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

PS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

9

7

10

12

 

 

 

 

 

 

 

 

 

 

11

 

 

 

C

 

 

 

 

 

 

 

LPS

HPS

 

 

 

 

 

 

 

 

 

 

 

NOTE 2

6

5

4

 

 

 

 

 

 

 

PLF

 

 

 

 

Y

 

 

3

2

1

R

G

W

Y1

 

C

 

Y2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLER/SERVICEMAN

STATUS LIGHT

EQUIP. STATUS

 

 

 

 

CHECK

 

 

 

 

 

 

 

 

 

ON

NORMAL OPERATION

-

 

OFF

NO POWER OR

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERNAL CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 BLINK

IGNITION FAILURE

 

 

 

 

GAS FLOW

 

 

 

 

GAS PRESSURE

 

OPEN ROLLOUT

 

 

 

 

GAS VALVE

 

SWITCH

 

FLAME SENSOR

 

OPEN AUX. LIMIT

 

FLAME ROLLOUT

 

 

 

 

BAD SWITCH

 

SWITCH

 

AUX. LIMIT OPEN

2 BLINKS

PRESSURE SWITCH

 

 

 

 

CHECK

 

 

OPEN

PRESSURE SWITCH

3 BLINKS

 

 

 

 

 

 

CHECK

 

 

 

WITHOUT INDUCER ON

PRESSURE SWITCH

4 BLINKS

OPEN LIMIT SWITCH

 

MAIN LIMIT OPEN

 

 

 

 

 

 

BAD SWITCH

5 BLINKS

FALSE FLAME SENSED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 BLINKS

COMPRESSOR

 

3 MIN. COMP.

 

OUTPUT DELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPONENT LEGEND

ALS

AUXILIARY LIMIT SWITCH

BC

BLOWER CONTACTOR

COMP

COMPRESSOR

CM

CONDENSER MOTOR

C

CONTACTOR

EM

EVAPORATOR MOTOR

F

FUSE

FC

FAN CAPACITOR

FS

FLAME SENSOR

GND

EQUIPMENT GROUND

GV

GAS VALVE

HPS

HIGH PRESSURE SWITCH

IBR

INDOOR BLOWER RELAY

IIC

INTEGRATED IGNITION CONTROL

IGN

IGNITOR

LPS

LOW PRESSURE SWITCH

LS

LIMIT SWITCH

PLF

FEMALE PLUG/CONNECTOR

PS

PRESSURE SWITCH

RS

ROLLOUT SWITCH

TB1

TERMINAL BLOCK (24V SIGNAL)

TR

TRANSFORMER

VM

VENT MOTOR

VMR

VENT MOTOR RELAY

NOTES

1.REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).

2.ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.

3.L1 AND L2 ON IIC CONTROL IS 24V INPUT.

4.USE COPPER CONDUCTORS ONLY.

USE NEC CLASS 2 WIRE.

5.FOR 208 VOLT TRANSFORMER OPERATION, MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER

CURRENT PROTECTION

208-240/3/60 0140L00979 REV A

FACTORY WIRING

LINE VOLTAGE

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FIELD WIRING

HIGH VOLTAGE

LOW VOLTAGE

WIRE CODE

BK BLACK

BL BLUE

BR BROWN

GR GREEN

OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW

BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP

THERMOSTAT

FIELD WIRING

NO ECONOMIZER

 

W

WH

W

G

GR

G

R

RD

R

Y1

 

 

Y/Y2

YL

Y

C

BL

C

TB1

 

STAT

 

 

WITH ECONOMIZER OPTION

W

WH

W

G

GR

G

R

RD

R

Y1

YL

Y

Y/Y2

 

 

C

BL

C

TB1

 

STAT

 

 

2 STAGE COOLING

 

W

WH

W

G

GR

G

R

RD

R

Y1

YL

Y1

Y/Y2

PK

Y2

C

BL

C

TB1

 

STAT

 

 

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

55

Page 55
Image 55
Goodman Mfg CPG SERIES installation manual 208-240/3/60 0140L00979 REV a

CPG SERIES specifications

Goodman Manufacturing has long been a trusted name in the HVAC industry, known for delivering reliable and efficient heating and cooling solutions. Among its impressive lineup is the CPG series, a collection of packaged units that cater to a wide range of residential and commercial applications. The CPG series is designed with the latest technologies and features, making it an ideal choice for those seeking comfort and performance.

One of the most significant characteristics of the CPG series is its energy efficiency. Engineered to meet rigorous energy standards, these units utilize advanced refrigerant technologies that not only lower energy consumption but also contribute to reducing environmental impact. The high-efficiency scroll compressor within the CPG series is designed to operate quietly and smoothly, ensuring that homeowners enjoy a comfortable indoor environment without disruptive noise.

The CPG series also stands out with its robust construction. Each unit is crafted from durable materials that can withstand various weather conditions, ensuring longevity and reliability. The all-aluminum evaporator coil enhances corrosion resistance, prolonging the unit's lifespan and maintaining optimal performance throughout its operation.

In terms of features, the CPG series offers an integrated microprocessor control system that optimizes performance based on real-time environmental data. This smart technology allows for accurate temperature control and improved efficiency by adapting to changing conditions. Furthermore, the series provides multiple capacity options, making it flexible for various building sizes and requirements.

Ease of installation and maintenance is another hallmark of the CPG series. These packaged units are designed for quick setup, reducing labor costs and installation time. Additionally, the access panels on the units are strategically placed, facilitating easier maintenance and servicing. This advantage not only enhances user convenience but also ensures that the units operate efficiently for years to come.

Moreover, the CPG series supports various accessories and enhancements, such as advanced filtration systems and programmable thermostats, allowing users to customize their HVAC system based on specific needs and preferences.

In conclusion, the Goodman CPG series embodies a perfect blend of efficiency, durability, and technology. With its focus on energy savings and user-friendly design, it represents a sound investment for those seeking superior HVAC solutions for their homes or commercial spaces. Whether it's for new construction or an upgrade to an existing system, the CPG series offers performance and reliability that customers can depend on.