Miller Electric Axcess manual Feeder Set Up Push Button, Adjust Control

Page 24

5-7. Feeder Set Up Push Button

3

4 Sequence

5 Trigger Control

Trigger Hold

1

Feeder Set Up

 

Start

Weld

Crater

 

Time

 

Time

Time

 

 

2

Preflow

 

 

 

 

 

Postflow

 

Time

 

 

 

Time

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Welding Sequence Diagram

1Feeder Set Up Push Button

2Feeder Set Up Push Button LED

Press button to choose sequence, trigger control, or trigger hold.

3Sequence LED

4Trigger Control LED

5Trigger Hold LED

6Lock LED (Access Allowed Only By Using An Optional PDA With File Management Software)

When the Feeder Set Up button is pressed while in standby, the Feeder Set Up push button LED illuminates and the top display will be active. Use the Adjust control to select preflow (PRE), start (STRT), crater (CRTR), or postflow (POST) parameters.

Press the lower display push button to allow the bottom display to become active. The time LED will automatically begin flashing

and the unit will be in the time mode. Initially, all sequences will appear as off. Use the Adjust control display time and enable the time sequence. Setting a time automatically enables a sequence. To turn off a sequence, change time setting to OFF.

If the sequence has a voltage or arc adjust setting, pressing the lower display push button a second time will cause either volts or arc adjust to appear on the display. Use the Adjust control to set either parameter.

If the sequence has a wire feed setting, pressing the lower display push button a third time will cause wfs to appear on the display. Use the Adjust control to set wire speed parameter.

Press the lower display push button a fourth time will cycle the display back to time.

Press the Feeder Set Up button a second time to go to Trigger Control mode and allow

the top display to become active. Use the Adjust control to cycle through trigger control methods as follows: dual schedule, trigger hold, trigger dual schedule, program select, 4T (see Section 5-1). The lower display will show the current state of each trigger control method as being either on or off. Not all trigger control methods are compatible with each other, and turning on certain functions will cause other trigger functions to turn off.

Press the lower display push button to allow the bottom display to become active. Use the Adjust control to turn selected trigger control methods on or off. If trigger hold is set to on, the trigger hold LED will illuminate. Note: if 4T is set to on, trigger hold will automatically be set to on since this parameter is necessary for the 4T function.

Press the Feeder Set Up button a third time to cycle back to standby mode.

5-8. Adjust Control

 

1 Adjust Control

 

The Adjust control is used to

 

change various sequence parame-

 

ters, and to select various se-

 

quences. Refer to the section for

 

the function in question for informa-

1

tion related to using the Adjust con-

trol.

Adjust

OM-211 076 Page 20

Image 24
Contents OM-211 076H ProcessesDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers UNE Décharge Électrique peut entraîner la mort LES Fumées ET LES GAZ peuvent être dangereuxIndique un message de sécurité particulier LE Soudage peut provoquer un Incendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaques− Installation Specifications− Introduction Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Pin Network Receptacle Information Gun Recommendation TableInstalling And Threading Welding Wire Feeder Display At Power Up Dual Schedule Switch OptionPower Source Upper Display Lower Display Voltage Range Upper Display Lower Display− Operation Operational TermsPower Switch See Section Program Volts Time Arc Adjust Front Panel ControlsSee SectionVolts Arc Adjust Program Push ButtonUpper Display Upper DisplayLower Display Feeder Set Up Push Button Adjust ControlSequence Trigger Control Trigger Hold Feeder Set Up Process Set Up Push Button Make a selection, rotate the Adjust controlJog/Purge Push Button Adjust Control Gun Trigger Receptacle Welding and to preset gas pressure at the regulatorJog/Purge Reset Mode PulseMild Steel Accu-pulse− Setting Sequence Parameters Sequence Parameters In a ProgramSequence Parameters − Maintenance Routine MaintenanceDiagnostics Closed error Indicates a triggerTroubleshooting Disconnect power before troubleshootingTrouble Remedy OM-211 076 − Electrical Diagram Circuit Diagram211 005-E − Parts List − Fig 21 − FigPart Description Quantity Control Box PLG4 Drive Assembly, Wire 1.2 mm 1.4 mmPage Service Your distributor also givesSupport To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s