Miller Electric Axcess manual Diagnostics

Page 30

7-2. Diagnostics

The following error messages are shown on the upper and lower displays to indicate specific errors. Explanations are in the text below:

ERR

TACH

Indicates a tachometer error.

ERR

MOTR

Indicates a motor error.

ERR

WFS

Indicates a wire feed speed error.

ERR

STRT

Indicates an arc start error.

ERR

STOP

Indicates an arc stop error.

ERR

FLOW

Indicates a gas flow error.

ERR

COOL

Indicates a coolant flow error.

ERR

GND

Indicates a ground current error.

ERR

STUK

Indicates a wire stuck error.

ERR

TEMP

Indicates a temperature error.

ERR

LINE

Indicates a line error.

ERR

ARC

Indicates an arc error.

ERR TACH

The tach error occurs 2 seconds after the loss of tachometer feedback. The motor speed is regulated through the monitoring of voltage and current. Press Jog/Purge button to clear error.

ERR MOTR

The motor error indicates that the motor has been drawing too much current for too long. To remedy this, reduce the wire feed speed or the wire feeder torque load/duty cycle. Press Jog/Purge button to clear error.

ERR WFS

The wire feed speed error indicates actual wire feed speed does not match wire feed speed command. Press Jog/Purge button to clear error.

ERR STRT

The start error occurs if the user has the trigger held for more than 3 seconds without striking an arc, or if a valid arc voltage and current is not detected. The 3 second arc start error time can be changed using an op- tional PDA with File Management software.

ERR STOP

The stop error occurs as result of obstructions in the wire feed system or a faulty wire drive system. Check wire feed and wire drive systems. Press Jog/Purge button to clear error.

ERR FLOW

The flow error indicates no gas flow to the gun. The error may be reset by reestablishing gas flow to the gun, and then pressing the Jog/Purge button.

ERR COOL

The cool error indicates no coolant flow in water flow switch option. The error may be reset by reestablishing coolant flow to the gun, and then pressing the Jog/Purge button.

ERR GND

The ground current error occurs if weld current is detected in the earth ground connection. May be caused by a conductor making contact with unit chassis. Check and repair feeder weld connections. Press Jog/Purge button to clear error.

ERR STUK

The stuck error occurs if the welding wire sticks to the workpiece at the end of a weld. May be caused by poor weld conditions. The error may be cleared by cutting wire from workpiece, and pressing the Jog/ Purge button.

ERR TEMP

The temperature error indicates welding power source has overheated and shutdown. The error may be cleared by allowing unit to cool down, and pressing the Jog/Purge button.

ERR LINE

The line error indicates input power is outside of unit operating range. Check and correct input power. Press Jog/Purge button to clear error.

ERR ARC

The arc error indicates an arc outage occurred possibly from a wire feeder error or power source error. Check wire feeder and power source. Press Jog/Purge button to clear error.

OM-211 076 Page 26

Image 30
Contents Description OM-211 076HProcesses File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers UNE Décharge Électrique peut entraîner la mort LES Fumées ET LES GAZ peuvent être dangereuxIndique un message de sécurité particulier DES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer unIncendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures graves’EMPLOI Excessif peut SUR Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaques− Introduction − InstallationSpecifications Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Pin Network Receptacle Information Gun Recommendation TableInstalling And Threading Welding Wire Power Source Upper Display Lower Display Voltage Range Feeder Display At Power UpDual Schedule Switch Option Upper Display Lower Display− Operation Operational TermsPower Switch See See Section Program Volts Time Arc AdjustFront Panel Controls SectionUpper Display Volts Arc AdjustProgram Push Button Upper DisplayLower Display Feeder Set Up Push Button Adjust ControlSequence Trigger Control Trigger Hold Feeder Set Up Process Set Up Push Button Make a selection, rotate the Adjust controlJog/Purge Push Button Adjust Control Gun Trigger Receptacle Welding and to preset gas pressure at the regulatorJog/Purge Mild Steel Reset ModePulse Accu-pulse− Setting Sequence Parameters Sequence Parameters In a ProgramSequence Parameters − Maintenance Routine MaintenanceDiagnostics Closed error Indicates a triggerTroubleshooting Disconnect power before troubleshootingTrouble Remedy OM-211 076 − Electrical Diagram Circuit Diagram211 005-E − Parts List − Fig 21 − FigPart Description Quantity Control Box PLG4 Drive Assembly, Wire 1.2 mm 1.4 mmPage Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s