SECTION 3 − INTRODUCTION

3-1. Specifications

Type of Input

Welding Power

Wire Feed Speed Range

Wire Diameter

Welding Circuit

Overall

Weight

Power

Source Type

Range

Rating

Dimensions

 

 

 

 

 

 

 

 

 

40 Volts DC

Axcess Series

Standard: 40 To 1400 ipm (1.0

.030 To 1/8 in

100 Volts,

Length: 27 in (686

46 lb

10 Amperes

 

To 35.6 mpm)

(0.8 To 3.2 mm)

750 Amperes,

mm)

(20.9 kg)

 

 

 

 

100% Duty

Width: 12-1/2 in

 

 

 

 

Max Spool

Cycle

 

 

 

 

(318 mm)

 

 

 

 

Weight: 60 lb (27

 

 

 

 

 

 

Height: 14-1/2 in

 

 

 

 

kg)

 

 

 

 

 

 

 

(368 mm)

 

 

 

 

 

 

 

 

SECTION 4 − INSTALLATION

4-1. Selecting A Location

Movement

OR

1

2

Tipping

Y Do not move or operate

 

unit where it could tip.

Location

YSpecial installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20.

4

3

18 in

(460 mm)

18 in

(460 mm)

YDo not stack units. Beware of tipping.

1 Lifting Forks

Use lifting forks to move unit.

Extend forks beyond opposite side of unit.

2 Hand Cart

Use cart or similar device to move unit.

3 Rating Label

Use rating label to determine input power needs.

4 Line Disconnect Device

Locate unit near correct input power supply.

loc_2 3/96 - Ref. 803 502-A

OM-211 076 Page 9

Image 13
Contents Processes OM-211 076HDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers LES Fumées ET LES GAZ peuvent être dangereux UNE Décharge Électrique peut entraîner la mortIndique un message de sécurité particulier Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéSpecifications − Installation− Introduction Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Gun Recommendation Table Pin Network Receptacle InformationInstalling And Threading Welding Wire Dual Schedule Switch Option Feeder Display At Power UpPower Source Upper Display Lower Display Voltage Range Upper Display Lower DisplayOperational Terms − OperationPower Switch Front Panel Controls See Section Program Volts Time Arc AdjustSee SectionProgram Push Button Volts Arc AdjustUpper Display Upper DisplayLower Display Adjust Control Feeder Set Up Push ButtonSequence Trigger Control Trigger Hold Feeder Set Up Make a selection, rotate the Adjust control Process Set Up Push ButtonWelding and to preset gas pressure at the regulator Jog/Purge Push Button Adjust Control Gun Trigger ReceptacleJog/Purge Pulse Reset ModeMild Steel Accu-pulseSequence Parameters In a Program − Setting Sequence ParametersSequence Parameters Routine Maintenance − MaintenanceDiagnostics Indicates a trigger Closed errorDisconnect power before troubleshooting TroubleshootingTrouble Remedy OM-211 076 Circuit Diagram − Electrical Diagram211 005-E − Fig 21 − Fig − Parts ListPart Description Quantity Control Box PLG4 Drive Assembly, Wire 1.4 mm 1.2 mmPage Your distributor also gives ServiceSupport Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s