5-4. Program Push Button

1

 

Program

3

2

 

1 Program Display

The number of the active program is displayed.

2Program Push Button

3Program Push Button LED

The LED lights to indicate that programs can be changed using the Adjust knob.

Momentarily press button to illuminate LED. To change the program number, rotate Adjust knob to select one of eight programs.

Pressing and holding the push button will display current wire size, wire type and process.

To reset feeder to factory settings, turn power source off for 10 seconds. Press and hold button in on power up, wait until top display shows RST and bottom display shows NO before releasing button. Feeder Set Up button LED will begin flashing. Turn Adjust knob to change bottom display to show YES, then press Feeder Set Up button to confirm selection. The top display will show CYCL and the lower display will show PWR. Turn welding power source power off for 10 seconds, then turn power back on again.

5-5. Upper Display

1

 

4

 

Volts

Arc Adjust

 

5

3

2

1 Upper Display

The upper display shows voltage or arc length. The unit displays both preset voltage or arc length and actual voltage. When welding, actual arc voltage is displayed.

2 Upper Display Push Button

Press the button to illuminate the LED and allow changing information in the display. Release button to display voltage.

3 Upper Display Push Button LED

The upper display push button LED

illuminates to indicate that information displayed can be changed by the Adjust control.

4Volts LED (Weld Voltage In MIG)

5Arc Adjust LED (Pulse Mode)

The LEDs below the display illuminate to indicate which value is being shown.

At any time while welding, the unit permits the adjustment of the weld voltage and overrides the display of actual arc voltage.

To activate Carbon Arc Cutting (CAC), press and hold the upper display push button in on power up. CAC will appear on the upper display and NO will appear on the lower display. Rotate adjust knob to YES on the lower display, and press the flashing Feeder Set up push button . CYCL will appear on the upper display and PWR will appear on the lower display. Turn welding power source off and back on again to enable the Carbon Arc Cutting process selection.

OM-211 076 Page 18

Image 22
Contents Description OM-211 076HProcesses File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers LES Fumées ET LES GAZ peuvent être dangereux UNE Décharge Électrique peut entraîner la mortIndique un message de sécurité particulier DES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer unIncendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures graves’EMPLOI Excessif peut SUR Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaques− Introduction − InstallationSpecifications Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Pin Network Receptacle Information Gun Recommendation TableInstalling And Threading Welding Wire Power Source Upper Display Lower Display Voltage Range Feeder Display At Power UpDual Schedule Switch Option Upper Display Lower Display− Operation Operational TermsPower Switch See See Section Program Volts Time Arc AdjustFront Panel Controls SectionUpper Display Volts Arc AdjustProgram Push Button Upper DisplayLower Display Adjust Control Feeder Set Up Push ButtonSequence Trigger Control Trigger Hold Feeder Set Up Process Set Up Push Button Make a selection, rotate the Adjust controlWelding and to preset gas pressure at the regulator Jog/Purge Push Button Adjust Control Gun Trigger ReceptacleJog/Purge Mild Steel Reset ModePulse Accu-pulseSequence Parameters In a Program − Setting Sequence ParametersSequence Parameters − Maintenance Routine MaintenanceDiagnostics Closed error Indicates a triggerDisconnect power before troubleshooting TroubleshootingTrouble Remedy OM-211 076 − Electrical Diagram Circuit Diagram211 005-E − Parts List − Fig 21 − FigPart Description Quantity Control Box PLG4 Drive Assembly, Wire 1.2 mm 1.4 mmPage Your distributor also gives ServiceSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s