Miller Electric 301 G manual Symbol Usage, Arc Welding Hazards

Page 5

SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING

rom _nd_10/02

YWarning: Protect yourself and others from injury — read and follow these precautions.

1-1. Symbol Usage

Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.

Y Marks a special safety message.

This group of symbols means Warning! Watch Out! possible

ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.

 

. Means “Note”; not safety related.

Consult symbols and related instructions below for necessary actions

to avoid the hazards.

1-2. Arc Welding Hazards

YThe symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Stan- dards listed in Section 1-7. Read and follow all Safety Standards.

YOnly qualified persons should install, operate, maintain, and re- pair this unit.

YDuring operation, keep everybody, especially children, away.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and

machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not use AC output in damp areas, if movement is confined, or if there is a danger of falling.

DUse AC output ONLY if required for the welding process.

DIf AC output is required, use remote output control if present on unit.

DAdditional safety precautions are required when any of the following electri- cally hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order present- ed: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone!

DDisconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DAlways verify the supply ground — check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.

DWhen making input connections, attach proper grounding conductor first − double-check connections.

DFrequently inspect input power cord for damage or bare wiring — replace cord immediately if damaged — bare wiring can kill.

DTurn off all equipment when not in use.

DDo not use worn, damaged, undersized, or poorly spliced cables.

DDo not drape cables over your body.

DIf earth grounding of the workpiece is required, ground it directly with a sep- arate cable.

DDo not touch electrode if you are in contact with the work, ground, or anoth- er electrode from a different machine.

DUse only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DClamp work cable with good metal-to-metal contact to workpiece or work- table as near the weld as practical.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

DDo not connect more than one electrode or work cable to any single weld output terminal.

SIGNIFICANT DC VOLTAGE exists in inverters after stop- ping engine.

DStop engine on inverter and discharge input capacitors according to instructions in Maintenance Section before touching any parts.

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases.

DIf ventilation is poor, use an approved air-supplied respirator.

DRead the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air- supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

BUILDUP OF GAS can injure or kill.

D Shut off shielding gas supply when not in use.

DAlways ventilate confined spaces or use approved air-supplied respirator.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.

DWear a welding helmet fitted with a proper shade of filter to protect your face and eyes from arc rays and sparks when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).

DWear approved safety glasses with side shields under your helmet.

DUse protective screens or barriers to protect others from flash and glare; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant material (wool and leather) and foot protection.

OM-4411 Page 1

Image 5
Contents Description OM-4411207 283EProcesses From Miller to You Table of Contents Options and Accessories Warranty Arc Welding Hazards Symbol UsageEngine Hazards Compressed Air Hazards California Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un in- cendie ou une explosionDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent provoquer des blessures ’EXPLOSION DE LA Batterie peutLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessuresInformation sur les champs électromagnétiques Principales normes de sécurité− Definitions Symbol DefinitionsWeld, Power, And Engine Specifications − SpecificationsDimensions, Weights, and Operating Angles DescriptionGenerator Power Curve Fuel Consumption While Welding And Using Generator Power100% Duty Cycle at 280 Amperes DC/CC Exceeding duty cycle can damage unit and void warrantyDuty Cycle CV/DC MIG Mode Stick And MIG Mode Volt-Ampere CurvesCC/DC Stick Mode DC TIG Mode Volt-Ampere Curves Installing Welding Generator − InstallationFull Gasoline Engine Prestart ChecksOil Do not overfill battery cells Activating The Dry Charge Battery If ApplicableRead and follow all instruc ChargerInstalling Exhaust Pipe Connecting The Battery+ − Connect negative − cable lastSelecting Weld Cable Sizes Connecting To Weld Output TerminalsSocket Information Remote Receptacle InformationReinstall side panel OM-4411 Adjusting Wire MIG Weld Puddle ConsistencyTools Needed 7/16 For wetter weld puddle for mild steelFront Panel Controls − Operating Welding GeneratorDescription Of Front Panel Controls Generator Power OutputEngine Speed Weld OutputSwitch Setting Process Output On/Off Control Process SwitchProcess Switch Settings Example Combination Remote Amperage Control Stick Remote Amperage/Voltage Control− Operating Auxiliary Equipment Hz Generator Power Receptacles And Circuit Breakers240 V 50 a AC Receptacle RC1 Circuit Breaker CB3Ceptacle RC3 Variable Frequency Hz Generator Power Receptacle RC3120 V 20 a Variable Frequency AC Receptacle RC3Receptacle Current Available in Amperes− Maintenance & Troubleshooting Maintenance Label Servicing Optional Spark Arrestor Oil Servicing Air CleanerFull Tools Needed Changing Engine Oil, Oil Filter, And Fuel FilterCircuit Breaker CB5 Overload ProtectionLocated behind front panel Tools Needed Trouble Remedy TroubleshootingWelding Variable Frequency Generator Power Receptacle RC3 Hz Generator Power Receptacles RC1 And RC2Engine Start Your Professional Welding Career Now Circuit Diagram For Welding Generator − Electrical Diagram211 395-C Grounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment How Much Power Does Equipment Require? Grounding When Supplying Building SystemsEarth ground if supplying Amperes x Volts = WattsApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Current Load Watts Amperes Selecting Extension Cord Use Shortest Cord PossibleMaterial Thickness Reference Chart − -3 41− -4 Main AssemblyBatt 182367 Panel Front w/Components -1Item Panel Front w/ComponentsPanel, Front w/Components Bracket w/Components Generator -1Item Support ServiceYour distributor also gives For assistance in filing or settling claims, contact Miller Electric Mfg. CoYour distributor and/or equipment manufacturer’s Transportation Department