Simer Pumps 4850C owner manual Safety, Ground pump before connecting to power supply

Page 2

Safety

2

Carefully read and follow all safety instructions in this manual or on pump.

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury!

DANGER warns about hazards that will cause serious personal injury, death or major property damage if ignored.

WARNING warns about hazards that can cause serious personal injury, death or major property damage if ignored.

CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored.

The word NOTICE indicates special instructions which are important but not related to hazards.

Hazardous voltage. Can shock, burn, or cause death.

Ground pump before connecting to power supply.

Pump is supplied with 3-conductor grounding

type cord. Connect only to properly grounded, GFCI protected outlet. Do not lift pump by electrical cord. Do not use an extension cord.

Pump is non-sub- mersible. Keep motor

dry at all times. Do not wash motor. Do not immerse. Pro-tect motor from wet weather.

Unplug pump before servicing.

1.To avoid risk of serious bodily injury and property damage, read safety instructions carefully before installing pump.

2.Follow local and/or national plumbing and electrical codes when installing pump.

3. To avoid fatal shocks, proceed as fol- lows if pump needs servicing:

A.Disconnect power to pump outlet box before pulling pump cord plug. After plug is pulled, let pump cool for 20 minutes before attempting to work on it.

B.Take extreme care when changing fuses. To re- duce chance of fatal electrical shocks, DO NOT stand in water or put your finger in the fuse socket.

C.Ground electrical outlet box.

D.Use only Ground Fault Circuit Interrupter (GFCI) protected grounded outlet for cord plug.

4.Never run pump dry. To do so can damage internal parts, overheat pump (which can cause burns to people handling or servicing pump), and will void warranty!

5. Risk of fire or explosion from sparks from motor brushes. Do not pump gasoline or any other flammable liquids with pump. Do not use pump in atmosphere that might contain flammable fumes or vapors.

6.Do not pump chemicals or corrosive liquids with pump.

Risk of fatal electrical shock if pump motor gets wet.

Keep motor dry.

Do not immerse pump or motor, or run pump if motor is wet.

If water is trapped in pump during opera- tion, it may turn to steam, leading to explosion and burns. Never run pump with outlet shut off or blocked.

NOTICE

Pump clean water only with pump. To avoid clogging pump and damage to shaft seal, do not pump water con- taining solids, foreign material, sand, silt, or abrasives. Always have suction strainer installed when pump is operating. Failure to use strainer may cause pump failure and void warranty.

Clean strainer and flush out pump after each use.

Make sure all hose and pipe connections in suction line are tight. An air leak in suction line will prevent priming and reduce performance.

To prevent damage to pump materials, do not use pipe joint compounds on pump ports. Use only teflon tape or Plasto-Joint-Stik* to seal threads.

Tighten all piping to pump hand tight +1-1/2 turns only. Overtightening may break pump and will void warranty.

Maximum liquid temperature is 120˚F (48.8˚C).

*Lake Chemical Co., Chicago, Illinois

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 2
Contents Phone Fax Model 4850CWright St., Delavan, WI EnglishSafety Ground pump before connecting to power supplyTable of Contents Piping InstallationLocation of Unit PRIMING/OPERATIONLubrication Pump ServiceSeal Changing Procedure Cord Replacement Motor Brush Replacement See Brush Changing Procedure,Brush Changing Procedure Fppkg 226-P2 Repair PartsKey Part Description Qty Part Number MotorMettre à la masse la boîte de sortie de courant SécuritéAvis Sécurité Garantie Remplacement des balais Pièces de rechangeTable des matières AMORCE/FONCTIONNEMENT Emplacement DE L’UNITÉTuyauterie Données ÉlectriquesEntretien DE LA Pompe Remplacement du jointGraissage Tension dangereuse. DébrancherRemplacement du cordon électrique Tension dangereuse. Avant d’inComment procéder pour remplacer les balais Réf Désignation des pièces Qté Pièces de rechangeNuméros Les bouchons MoteurSeguridad AvisoRefacciones Indice de ContenidoSeguridad General Garantía Teléfono 1-800-468-7867/1-800-546-7867 FaxTuberías InstalaciónUbicación DE LA Unidad Cebado Y OperaciónProcedimiento para cambiar la junta LubricaciónServicio DE LA Bomba Reemplazo del cordón Procedimiento para cambiar las escobillas Descripción de la pieza Cantidad De pieza RefaccionesNúmero

4850C specifications

The Simer Pumps 4850C is a versatile and robust solution designed for various applications, including water transfer, irrigation, and dewatering tasks. Its commitment to quality and performance positions it as a reliable choice for both residential and commercial users.

One of the standout features of the Simer Pumps 4850C is its powerful electric motor. This high-efficiency motor operates at 1.5 horsepower, providing ample power for tackling demanding tasks with ease. The motor is designed for longevity, with thermal overload protection that prevents overheating and ensures optimal performance during extended use.

The pump’s construction is another key characteristic that enhances its durability and efficiency. Made from high-quality materials, the Simer Pumps 4850C boasts a corrosion-resistant pump body that withstands the test of time, even when exposed to harsh environmental conditions. This is particularly important for outdoor applications where weather exposure can lead to wear and tear.

In terms of technology, the Simer Pumps 4850C features an innovative impeller design which ensures high flow rates and efficiency. The open impeller allows for the handling of solids, making the pump suitable for a wide range of liquids, including those with some particulate matter. This versatility makes it an ideal choice for both clean and slightly dirty water applications.

The design of the Simer Pumps 4850C also incorporates a user-friendly interface. It includes a convenient quick-connect fitting that allows for easy installation and removal, minimizing downtime and making maintenance more straightforward. Additionally, the pump is equipped with a built-in carry handle, making it portable and easy to transport for various tasks.

For those concerned about efficiency, the Simer Pumps 4850C operates with low power consumption, ensuring reduced electricity bills without sacrificing performance. The pump's noise level is also kept to a minimum, which is a significant advantage in residential areas or noise-sensitive environments.

Overall, the Simer Pumps 4850C combines robust construction, efficient operation, and advanced design technology, making it an exceptional choice for anyone in need of a reliable water pump. Whether you need it for residential or commercial use, the 4850C promises to deliver consistent performance and longevity, ensuring it can handle whatever tasks you throw its way.