Simer Pumps 4850C owner manual Lubrication, Pump Service, Seal Changing Procedure

Page 5

Installation

5

NOTICE: Pump motor is equipped with carbon brushes with a normal operating life of about 300 hours. One extra set of brushes is included. Replacement brushes are available from your dealer. Motor brushes not included in warranty.

Fire hazard. Incorrectly mounted brushes may cause fire. Be sure curve on end of brush matches curve on commutator.

LUBRICATION

Motor is lubricated at factory for life of bearings. Pump seal is water cooled and self lubricating.

PUMP SERVICE

Motor has auto-reset thermal overload. If motor over- heats, overload will cut off power to prevent damage and will reset after motor cools. If overload trips repeat- edly, check pump for cause (low voltage, clogged impeller, etc.).

Hazardous voltage. Can shock, burn, or cause death. Disconnect motor from electrical power before servicing pump.

Always replace both brushes - to avoid fire hazard, never replace just one.

Seal Changing Procedure

Hazardous voltage. Unplug pump before continuing.

1.Unplug the pump from the outlet and remove all piping or hoses from the pump.

2.To avoid breaking the brushes when you remove or replace the motor shaft, remove the motor brushes (see “Brush Changing Procedure”, Page 7, Steps 1 and 2). Put the brushes where they will not get lost or damaged while you proceed.

3.Remove 4 screws from the back of the pump body (Key No. 1, Page 8) and remove the pump body from the motor. Remove the old Square-cut O-Ring (Key No. 4C) from the assembly.

4.Unscrew the impeller (Key No. 4A) from the motor shaft and discard it.

5.Pull the seal plate (Key No. 5) from the motor shaft.

6.Turn the seal plate face down (See Figure 4A) and use a screwdriver or small tube to push the station- ary seal half out of the seal plate (Figure 4B).

7.Place a cardboard washer over the seal face to pro- tect it and use a tube to push the stationary seal half into the seal plate until it seats (Figure 4C). Be sure you don’t scratch or mar the polished face of the seal. Also, keep your hands away from the seal face to keep dirt and grease off of it.

A

C

B

D

5678 0807

Figure 4: Seal Changing Procedure

8.Use the cardboard washer and tube to push the rotating half of the seal into the new impeller, pol- ished face out (Figure 4D). Be sure you don’t scratch or mar the polished face of the seal. Also, keep your hands away from the seal face to keep dirt and grease off of it.

9.CAREFULLY slide the seal plate back onto the motor shaft, making sure that you don’t chip or scratch the seal face in the process.

10.Thread the new impeller onto the motor shaft, making sure that you don’t chip or scratch the seal face in the process.

11.Reinstall the motor shaft in the motor.

12.Install the new square-cut O-ring on the seal plate.

13.Bring the impeller/motor assembly up to the pump body and insert the impeller and seal plate into the pump body.

14.Install the 4 body screws (be sure to reinstall the handle on the upper screws) and tighten them securely.

15.Replace the motor brushes (see “Brush Changing Procedure”, Page 7, Steps 4, 5, and 6).

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 5
Contents Wright St., Delavan, WI Model 4850CPhone Fax EnglishGround pump before connecting to power supply SafetyTable of Contents Location of Unit InstallationPiping PRIMING/OPERATIONLubrication Pump ServiceSeal Changing Procedure Motor Brush Replacement See Brush Changing Procedure, Cord ReplacementBrush Changing Procedure Key Part Description Qty Part Number Repair PartsFppkg 226-P2 MotorMettre à la masse la boîte de sortie de courant SécuritéAvis Sécurité Garantie Remplacement des balais Pièces de rechangeTable des matières Tuyauterie Emplacement DE L’UNITÉAMORCE/FONCTIONNEMENT Données ÉlectriquesGraissage Remplacement du jointEntretien DE LA Pompe Tension dangereuse. DébrancherTension dangereuse. Avant d’in Remplacement du cordon électriqueComment procéder pour remplacer les balais Numéros Pièces de rechangeRéf Désignation des pièces Qté Les bouchons MoteurAviso SeguridadSeguridad General Garantía Indice de ContenidoRefacciones Teléfono 1-800-468-7867/1-800-546-7867 FaxUbicación DE LA Unidad InstalaciónTuberías Cebado Y OperaciónProcedimiento para cambiar la junta LubricaciónServicio DE LA Bomba Reemplazo del cordón Procedimiento para cambiar las escobillas Descripción de la pieza Cantidad De pieza RefaccionesNúmero

4850C specifications

The Simer Pumps 4850C is a versatile and robust solution designed for various applications, including water transfer, irrigation, and dewatering tasks. Its commitment to quality and performance positions it as a reliable choice for both residential and commercial users.

One of the standout features of the Simer Pumps 4850C is its powerful electric motor. This high-efficiency motor operates at 1.5 horsepower, providing ample power for tackling demanding tasks with ease. The motor is designed for longevity, with thermal overload protection that prevents overheating and ensures optimal performance during extended use.

The pump’s construction is another key characteristic that enhances its durability and efficiency. Made from high-quality materials, the Simer Pumps 4850C boasts a corrosion-resistant pump body that withstands the test of time, even when exposed to harsh environmental conditions. This is particularly important for outdoor applications where weather exposure can lead to wear and tear.

In terms of technology, the Simer Pumps 4850C features an innovative impeller design which ensures high flow rates and efficiency. The open impeller allows for the handling of solids, making the pump suitable for a wide range of liquids, including those with some particulate matter. This versatility makes it an ideal choice for both clean and slightly dirty water applications.

The design of the Simer Pumps 4850C also incorporates a user-friendly interface. It includes a convenient quick-connect fitting that allows for easy installation and removal, minimizing downtime and making maintenance more straightforward. Additionally, the pump is equipped with a built-in carry handle, making it portable and easy to transport for various tasks.

For those concerned about efficiency, the Simer Pumps 4850C operates with low power consumption, ensuring reduced electricity bills without sacrificing performance. The pump's noise level is also kept to a minimum, which is a significant advantage in residential areas or noise-sensitive environments.

Overall, the Simer Pumps 4850C combines robust construction, efficient operation, and advanced design technology, making it an exceptional choice for anyone in need of a reliable water pump. Whether you need it for residential or commercial use, the 4850C promises to deliver consistent performance and longevity, ensuring it can handle whatever tasks you throw its way.