Simer Pumps 4850C Cord Replacement, Motor Brush Replacement See Brush Changing Procedure

Page 6

Installation

6

Cord Replacement

Hazardous voltage. Unplug pump before working on or servicing pump. Don’t attempt to modify the cord or plug; these instructions are ONLY for replacement of cord.

1.Unplug the pump.

2.Unscrew the two screws holding the cord plate to the back of the motor. Pull the cord gently out of the motor cavity.

3.Cut the existing wires on the motor side of the crimps, as close to the connectors as possible (in other words, leave yourself as much wire in the motor as possible).

4.Strip all the wires back about 5/8” from the wire ends.

NOTE: Make connections with wire nuts designed for connecting 2 #16 AWG wires (see the wire nut package).

5.Connect the green (ground) wire from the cord to the green (ground) wire from the motor. Connect the black (hot) wire from the cord to either black wire from the motor. Connect the white (neutral) wire from the cord to the remaining black wire from the motor.

6.After you have made the connections, check all con- nections carefully to be sure that no bare copper shows. If you see any bare wire, disconnect the wire nut and remake that connection.

7.Once you are sure that there is no exposed wire, carefully stuff the wire and wire nuts back into the cavity in the motor.

8.Hold the cord plate up against the motor and rein- stall the screws. Tighten thoroughly but do not over- tighten!

9.Once assembly is complete, SET THE PUMP DOWN (that is, don’t touch it) and plug it in (very briefly, to avoid damaging the shaft seal) to make sure that everything is correctly connected and nothing is shorted.

10. The pump is ready for operation.

Motor Brush Replacement (See Brush Changing Procedure, page 7:

Replace brushes when they wear down to 3/8" (9.5mm) length.

1.Unplug pump from power outlet.

2.Unscrew brush caps and remove brushes. NOTICE: Pull brushes straight out of holders, being careful not to stretch springs. If reusing same brushes, mark brush and brush cap for replacement to original position.

3.Install new brushes and brush caps.

NOTICE: When reinstalling same brushes that were removed, replace on same side of motor they were on originally. Match curve on ends of brushes to curve on commutator.

For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Image 6
Contents Phone Fax Model 4850CWright St., Delavan, WI EnglishSafety Ground pump before connecting to power supplyTable of Contents Piping InstallationLocation of Unit PRIMING/OPERATIONPump Service Seal Changing ProcedureLubrication Cord Replacement Motor Brush Replacement See Brush Changing Procedure,Brush Changing Procedure Fppkg 226-P2 Repair PartsKey Part Description Qty Part Number MotorSécurité AvisMettre à la masse la boîte de sortie de courant Remplacement des balais Pièces de rechange Table des matièresSécurité Garantie AMORCE/FONCTIONNEMENT Emplacement DE L’UNITÉTuyauterie Données ÉlectriquesEntretien DE LA Pompe Remplacement du jointGraissage Tension dangereuse. DébrancherRemplacement du cordon électrique Tension dangereuse. Avant d’inComment procéder pour remplacer les balais Réf Désignation des pièces Qté Pièces de rechangeNuméros Les bouchons MoteurSeguridad AvisoRefacciones Indice de ContenidoSeguridad General Garantía Teléfono 1-800-468-7867/1-800-546-7867 FaxTuberías InstalaciónUbicación DE LA Unidad Cebado Y OperaciónLubricación Servicio DE LA BombaProcedimiento para cambiar la junta Reemplazo del cordón Procedimiento para cambiar las escobillas Refacciones NúmeroDescripción de la pieza Cantidad De pieza

4850C specifications

The Simer Pumps 4850C is a versatile and robust solution designed for various applications, including water transfer, irrigation, and dewatering tasks. Its commitment to quality and performance positions it as a reliable choice for both residential and commercial users.

One of the standout features of the Simer Pumps 4850C is its powerful electric motor. This high-efficiency motor operates at 1.5 horsepower, providing ample power for tackling demanding tasks with ease. The motor is designed for longevity, with thermal overload protection that prevents overheating and ensures optimal performance during extended use.

The pump’s construction is another key characteristic that enhances its durability and efficiency. Made from high-quality materials, the Simer Pumps 4850C boasts a corrosion-resistant pump body that withstands the test of time, even when exposed to harsh environmental conditions. This is particularly important for outdoor applications where weather exposure can lead to wear and tear.

In terms of technology, the Simer Pumps 4850C features an innovative impeller design which ensures high flow rates and efficiency. The open impeller allows for the handling of solids, making the pump suitable for a wide range of liquids, including those with some particulate matter. This versatility makes it an ideal choice for both clean and slightly dirty water applications.

The design of the Simer Pumps 4850C also incorporates a user-friendly interface. It includes a convenient quick-connect fitting that allows for easy installation and removal, minimizing downtime and making maintenance more straightforward. Additionally, the pump is equipped with a built-in carry handle, making it portable and easy to transport for various tasks.

For those concerned about efficiency, the Simer Pumps 4850C operates with low power consumption, ensuring reduced electricity bills without sacrificing performance. The pump's noise level is also kept to a minimum, which is a significant advantage in residential areas or noise-sensitive environments.

Overall, the Simer Pumps 4850C combines robust construction, efficient operation, and advanced design technology, making it an exceptional choice for anyone in need of a reliable water pump. Whether you need it for residential or commercial use, the 4850C promises to deliver consistent performance and longevity, ensuring it can handle whatever tasks you throw its way.