Miller Electric CV-2 owner manual Cable

Page 9

 

Rear View (Inside)

Left Front Upright When

 

Of Lower Front Panel

 

Viewed From Front

 

 

Of Control Panel

 

 

Electrode (Negative)

 

Cable 28

Weld Output Terminal

 

 

 

 

Weld Output

 

 

Terminal Assembly

 

 

Work (Positive)

 

 

Weld Output

Cable 30 From Negative

 

Terminal

Cable 30

 

Weld Output Terminal

 

 

 

And Black Voltmeter Lead,

 

 

If Applicable

 

Bimetal Jumper

 

 

Bar-Copper Side

 

 

Of Bar Against

Cable 19 From Positive

 

Terminal Surface

Weld Output Terminal

 

 

Cable Lug Connection

 

With Tubing And Ties

 

 

Selector

Cable 19

 

Switch S1

SB-112 688-A

Figure 3-2. Selector Switch S1 DC Connections

WARNING: ELECTRIC SHOCK can kill; BI-

METAL JUMPER BAR CONTACT WITH IN- TERNAL COMPONENTS can cause per- sonal injury and equipment damage.

Do not touch live electrical parts.

Do not allow bimetal jumper bar to touch metal surfaces or internal components other than the intended connection.

Route bimetal jumper bar so it is not touching other surfaces or components between connec- tion points during operation.

IMPORTANT: Be sure that copper side of bimetal jumper bar is in contact with copper surface of output terminal when making connections.

10.Connect bimetal jumper bar from switch S1 to rear of Positive weld output terminal (see Figure 3-2).

11.For BIG 30 DIESEL and BIG 30A DIESEL mod- els, connect cables 17 and 27 from CV-2 Selector switch S1 as follows:

a.Locate and install supplied cables 17 and 27 on existing cables 17 and 27 on S1. Be sure that the lugs on the nonconnected ends of the sup- plied cables have the larger diameter hole. Se- cure the cable lug connections using the sup- plied 1/4-20 x 3/4 in. screws, flat washers (4), and nuts.

b.Slide a 6 in. (152 mm) long piece of supplied in- sulated tubing over each connection. Secure in- sulated tubing with the supplied nylon cable ties.

c.Route cables over top of stator barrel and to right side of unit. Connect cables from S1 to rec- tifier SR3 with existing cables 17 and 27 below right rear corner of the fuel tank (see Figure 3-3).

12.For BIG 40 DIESEL, BIG 40G, and BIG 50 DIE- SEL models, connect cables 17 and 27 from CV-2 Selector switch S1 as follows:

a.Route cables from S1 up to range switch S3.

b.Connect S1 cables with existing cables 17 and 27 at appropriate terminals on S3 (see Figure 3-3).

13.Connect lead 100 from installed transformer T2 to terminal D on CV-2 terminal strip 3T (see Parts List view for CV-2 component locations).

14.Connect lead 205 from T2 to piggyback connec- tor on existing lead 205 at CV/CC switch S12 on CV-2 panel (see Parts List view for CV-2 compo- nent locations).

15.Connect lead 206 from T2 to the unused terminal at circuit breaker CB6 on CV-2 panel (see Parts List view for CV- component locations).

16.Locate leads 623, 625, 628, 632, and 634 hang- ing from Current Regulator box on rear of front panel. Cut and remove nylon cable ties holding leads together (see Figure 3-4).

17.Disconnect leads 628 and 634 at insulated fric- tion terminals, and connect these leads to the matching leads from the CV-2 panel (see Figure 3-4).

OM-880 Page 5

Image 9
Contents OWNER’S Manual From Miller to You Table of Contents Page Specifications Safety Precautions and Signal WordsGeneral Information and Safety Safety Alert Symbol and Signal WordsBIG 50 Diesel Models BIG 40 Diesel And BIG 40G ModelsInstallation or Relocation CV-2 InstallationDescription BIG 30 Diesel Cable Selector Switch S1 AC Connections OM-880 Final Procedure REMOTE-5REMOTE-5 Receptacle Information and Connections -6 REMOTE-14 Receptacle Information and Connections Figures 3-7 REMOTE-14Amphenol Electrode Cable Series Current CC Switch Figure Current Control Switch FigureOperator Controls Current Control RemoteOutput Contactor Remote Electrode POS NEGCircuit Breaker GAS Metal ARC Gmaw and Flux Cored ARC Welding Fcaw Sequence of OperationGAS Tungsten ARC Welding Gtaw Shielded Metal ARC Welding SmawShutting Down Maintenance & Troubleshooting Excessive Pressure can break circuit board Tungsten Electrode -2, And Figures 6-2For AC or DC Electrode Positive Welding Fig- ure Green Band Thorium Alloyed Tungsten Red BandZirconium Alloyed Tungsten Brown Band Tungsten Preparation Trouble Probable Remedy TroubleshootingDiagram 7-2. Wiring Diagram For CV-2 Electrical DiagramParts List Main Assembly Dia Part Description Quantity Mkgs Call Miller for your local Miller distributor Miller Electric Mfg. Co Owner’s Record