10-3. Run-In Procedure Using Resistance Grid
|
|
| Y | Stop engine. |
|
|
| Y Do not touch hot exhaust | |
|
|
|
| pipe, engine parts, or load |
|
|
|
| bank/grid. |
|
|
| Y Keep exhaust and pipe away | |
6 |
|
|
| from flammables. |
|
| Y Do not perform | ||
|
|
| ||
| 2 |
|
| procedure at less than 20 |
|
|
| volts weld output and do not | |
|
|
|
| exceed duty cycle or equip- |
|
|
|
| ment damage may occur. |
|
|
| 1 | Resistance Grid |
|
|
| Use grid sized for generator rated | |
|
|
| output. | |
|
| 1 | Turn Off grid. | |
|
| 2 | Welding Generator | |
|
|
| ||
|
|
| Place Welder Selector switch in | |
|
|
| Welder B position (600 Amps), A/V | |
|
|
| control in minimum position, and | |
|
|
| both Process Selector switches in | |
|
|
| Stick/TIG position. | |
|
|
| 3 | Weld Cables |
|
|
| Connect grid to generator Welder B | |
|
|
| (right) weld output terminals using | |
|
|
| proper size weld cables with cor- | |
|
|
| rect connectors (polarity is not im- | |
|
|
| portant). | |
|
|
| 4 | Voltmeter |
|
|
| 5 | |
|
|
| Connect voltmeter and ammeter as | |
|
|
| shown, if not provided on generator. | |
3 | 5 |
| Start engine and run for several | |
|
|
| minutes. | |
|
|
| Set grid switches and then adjust | |
|
|
| generator A/V control so load | |
|
|
| equals 350 Amps at 40 volts. | |
4 |
|
| Check generator and meters after | |
|
| first five minutes then every fifteen | ||
|
|
| minutes to be sure generator is | |
|
|
| loaded properly. | |
+ |
|
| . Check oil level frequently dur- | |
|
|
| ing | |
|
|
| After one hour (minimum), place | |
|
|
| A/V control in minimum position, | |
|
|
| then shut down grid to remove load. | |
|
|
| Run engine several minutes at no | |
|
|
| load. | |
|
|
| Y Stop engine and let cool. | |
|
|
| 6 | Engine Exhaust Pipe |
|
|
| Repeat procedure if wetstacking is | |
|
|
| present. |