Miller Electric Renegade 180 manual HOT Parts can cause burns and injury, Fire or Explosion hazard

Page 8

HOT METAL from air arc cutting and gouging can cause fire or explosion.

DDo not cut or gouge near flammables.

DWatch for fire; keep extinguisher nearby.

HOT PARTS can cause burns and injury.

DDo not touch hot compressor or air system parts.

DLet system cool down before touching or ser- vicing.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servic- ing unit.

DStop engine and release air pressure before servicing.

DUse only genuine replacement parts from the manufacturer.

1-5. Additional Symbols For Installation, Operation, And Maintenance

FIRE OR EXPLOSION hazard.

D Do not install or place unit on, over, or near combustible surfaces.

DDo not install unit near flammables.

DDo not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.

WELDING WIRE can cause injury.

DDo not press gun trigger until instructed to do so.

DDo not point gun toward any part of the body, other people, or any metal when threading welding wire.

FALLING UNIT can cause injury.

DUse lifting eye to lift unit and properly installed accessories only, NOT gas cylinders. Do not exceed maximum lift eye weight rating (see Specifications).

DLift and support unit only with proper equipment and correct procedures.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

OVERHEATING can damage motors.

DTurn off or unplug equipment before starting or stopping engine.

DDo not let low voltage and frequency caused by low engine speed damage electric motors.

DDo not connect 50 or 60 Hertz motors to the 100 Hertz receptacle where applicable.

FLYING SPARKS can cause injury.

D Wear a face shield to protect eyes and face.

D Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection.

DSparks can cause fires — keep flammables away.

MOVING PARTS can cause injury.

DKeep away from moving parts.

DKeep away from pinch points such as drive rolls.

OVERUSE can cause OVERHEATING.

DAllow cooling period; follow rated duty cycle.

DReduce current or reduce duty cycle before starting to weld again.

DDo not block or filter airflow to unit.

STATIC (ESD) can damage PC boards.

DPut on grounded wrist strap BEFORE handling boards or parts.

DUse proper static-proof bags and boxes to store, move, or ship PC boards.

TILTING OF TRAILER can cause injury.

DUse tongue jack or blocks to support weight.

DProperly install welding generator onto trailer according to instructions supplied with trailer.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servic- ing unit.

DUse only genuine replacement parts from the manufacturer.

DPerform engine and air compressor mainte- nance and service according to this manual and the engine/air compressor (if applicable) manuals.

OM-228 042 Page 4

Image 8
Contents OM-228 042B ProcessesDescription File Engine DriveFrom Miller to You Table of Contents − Maintenance 10-1Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous Buildup of GAS can injure or killARC Rays can burn eyes and skin Welding can cause fire or explosionEngine Hazards Compressed Air HazardsWelding Wire can cause injury HOT Parts can cause burns and injuryFire or Explosion hazard Falling Unit can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer Indique des instructions spécifiquesLE Soudage peut provoquer un in cendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux DES Organes Mobiles peuvent pro voquer des blessures LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peu Risque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures LE Surchauffement peut endom- mager le moteur électrique DES Organes Mobiles peuvent provoquer des blessuresLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutInformation EMF Proposition californienne 65 AvertissementsPrincipales normes de sécurité − Specifications Symbol DefinitionsWeld, Power, And Engine Specifications − DefinitionsGun Specifications Dimensions, Weights, And Operating AnglesOptional Lifting Eye Weight Rating Volt-Ampere CurvesPower Source Duty Cycle Fuel ConsumptionGenerator Power Curve Gun Duty Cycle And OverheatingVolts AC Amperes− Installation Installing Welding GeneratorMovement Airflow ClearanceGrounding Generator When Supplying Building Systems Use ground device as stated in electrical codesConnecting The Battery Electric Start Models Only Engine Prestart Checks+ − OilInstalling Welding Gun Work Cable Routing Inside UnitWeld Process/Polarity Table Changing Weld PolarityThis unit can provide weld out Connecting Single−Phase, 230 Volt AC Utility Input PowerShown with optional cylinder rack Electrical Service Guide Installing Wire Spool And Adjusting Hub TensionWhen a slight force is needed to turn spool, tension is set AdapterWeld Position Tools Needed 150 mm 030/.035 Groove Stamped Stamped .030/.035 Tighten Pressure Indicator ScaleThreading The Welding Gun Wood − Operating the Welding Generator Controls See SectionTo Stop Description Of Controls See SectionTo Start Weld Parameter Chart Stainless Steel And 100% CO2 Weld Parameters 20 ga 18 ga 16 ga 14 ga− Operating Auxiliary Equipment Generator Power Panel ReceptaclesGenerator power decreases as weld current increases − Maintenance Power Source Routine MaintenanceGun Routine Maintenance Welding Power Source Overload ProtectionDrive Motor Protection Tip Saver/Short Circuit ProtectionReplacing Gun Contact Tip Changing Drive Roll Or Wire Inlet GuideTurn Off power before replacing contact tip Turn off welding power source/wire feeder Maintaining GunReplacing Switch And/Or Head Tube Tools Needed 19 mmServicing Air Cleaner Precleaner Paper ElementDo not wash paper element or clean with compressed air Standard Model Shown Stop engineAdjusting Engine Speed Stop engine. Close fuel valve− Troubleshooting TroubleshootingGenerator Power WeldingDoes not run Wire FeederEngine Recommended Spare Parts − Parts ListRecommended Spare Parts − Electrical Diagrams OM-217 454Regulator Flowmeter Wire Feeder Power Source Shielding Gas − MIG Welding Gmaw GuidelinesTypical MIG Process Connections Gun Work Clamp WorkpieceTypical MIG Process Control Settings These settings are guidelines only. MaterialWire Suggested Wire Speed Material thickness determines weld parametersNozzle, and tip of wire is posi Holding And Positioning Welding GunTioned correctly on seam Groove WeldsConditions That Affect Weld Bead Shape Gun Angles And Weld Bead ProfilesElectrode Extensions Stickout Fillet Weld Electrode Extension StickoutGun Movement During Welding Poor Weld Bead CharacteristicsGood Weld Bead Characteristics Possible Causes Corrective Actions Troubleshooting − Excessive SpatterTroubleshooting − Porosity Troubleshooting − Incomplete Fusion Troubleshooting − Excessive Penetration12-11 Troubleshooting − Lack Of Penetration Troubleshooting − Distortion 12-13 Troubleshooting − Burn-ThroughTroubleshooting − Waviness Of Bead Flat & Horizontal1 Fillet Common MIG Shielding GasesApplication Grounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment Grounding When Supplying Building Systems How Much Power Does Equipment Require?Approximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Cord Lengths for 120 Volt LoadsCurrent Load Watts Amperes Cord Lengths for 240 Volt LoadsSOCKET/WRENCH Selection Table Standard Metric Support ServiceYour distributor also gives To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s