5-9. Connecting Single−Phase, 230 Volt AC Utility Input Power
1
6 | =GND/PE Earth Ground |
| |
| 8 |
5
7
L1 | 2 | |
L2 | ||
| ||
3 |
| |
| 10 |
4 | L2 | L1 |
|
| 230 VAC, 1 |
1
Tools Needed: | 9 |
. Shown with optional cylinder rack |
.This unit can provide weld out-
put using the engine to power the welding power source/wire feeder OR single−phase 230 volt ac utility power can be used to power the welding pow- er source/wire feeder.
Installation must meet all Na- tional and Local Codes − have only qualified persons make this installation.
Disconnect and lockout/tag- out input power before con- necting input conductors from unit.
Always connect green or green/yellow conductor to supply grounding terminal first, and never to a line ter- minal.
1 Rating Label
Supply correct input power.
2Black And White Input Conductor (L1 And L2)
3Green Or Green/Yellow Grounding Conductor
4Input Power Cord.
5Disconnect Device (switch shown in the OFF position)
6Disconnect Device Grounding Terminal
7Disconnect Device Line Terminals
Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.
Connect input conductors L1 and L2 to disconnect device line termi- nals.
8
Select type and size of
Close and secure door on discon- nect device. Remove lockout/tag- out device, and place switch in the On position.
9Plug (NEMA
10Receptacle (NEMA
Special installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20.