4-7. Remote 14 Receptacle RC3 Information (Optional, See Section 4-8)
A J
B K I
C L N H
D M G
EF
Ref.
| Socket* | Socket Information | |
| A | 24 volts ac. Protected by circuit | |
|
| breaker CB4. | |
| B | Contact closure to A completes 24 | |
|
| volts ac contactor control circuit. | |
| I | 115 volts ac. Protected by circuit | |
|
| breaker CB3. | |
| J | Contact closure to I completes 115 | |
|
| volts ac contactor control circuit. | |
| G | Circuit common for 24 and 115 volts ac | |
|
| circuits. | |
| C | 0 to +10 volts dc output to remote | |
|
| control. | |
A/V | D | Remote control circuit common. | |
E | 0 to +10 volts dc input command signal | ||
| |||
|
| from remote control. | |
| K | Chassis common. |
*The remaining sockets are not used.
4-8. Terminal Strip 3T Connections (Optional)
Y Stop engine.
If remote control plug does not fit in receptacle RC3, wire cord directly to terminal strip 3T.
Y Do not connect to Remote 14 receptacle RC3 and terminal strip 3T at the same time. Use only one remote control method.
Open right side door.
1 Cover
2 Terminal Strip 3T
Connect leads to 3T using terminal information shown in Section
Reinstall cover. Close door.
2
1
Tools Needed:
Ref.