7-3. Servicing Air Cleaner
Y Stop engine.
Y Do not run engine without air cleaner or with dirty element.
Clean or replace element if dirty or damaged. Replace element yearly or after six cleanings.
1 Dust Cap
5 | 4 | 3 | 2 | 1 |
2 Baffle
3 Element
4 Plastic Fins
5 Housing
To Clean air filter:
Wipe off cap and housing. Remove cap and dump out dust. Wipe dust from inside cap and housing with damp cloth. Remove element and reinstall cap.
Y Do not clean housing with air hose.
Clean element with compressed air only. Keep nozzle at least 1 in (25 mm) from inside of element. Max. air pressure: 100 psi (690 kPa). Do not remove plastic fins. Replace ele- ment if it has holes or damaged gaskets.
Reinstall element and cap (cap arrows pointing up).
BlowInspect
aircleaner1 6/96 –
7-4. Overload Protection
Y Stop engine.
. If any fuse or circuit breaker continues to open, contact Fac- tory Authorized Service Agent.
1 Magnetic Shutdown
Switch MS1
2 Fuse F (See Parts List)
Fuse F protects magnetic shutdown switch MS1. If fuse F opens, the engine stops.
Check fuse and replace if open.
3 Circuit Breaker CB3 (Optional)
4 Circuit Breaker CB4 (Optional)
CB3 protects the 115 volt ac output and CB4 protects the 24 volt ac out- put to optional Remote 14 recep- tacle RC3 and terminal strip 3T. If a circuit breaker opens, 24 or 115 volts ac output stops.
1 | 3 | 4 | Press button to reset breaker. |
2
Tools Needed:
Ref.