Troubleshooting / Repair Parts |
| 5 | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
SYMPTOM |
|
| PROBABLE CAUSE(S) |
|
|
| CORRECTIVE ACTION |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Pump won’t start or run. |
| Blown fuse or breaker. |
|
| If blown, replace with fuse of proper size or reset breaker. | ||||||||
|
|
| Low line voltage. |
|
| If voltage under recommended minimum, check size of wiring from | |||||||
|
|
|
|
|
|
|
| main switch on property. If OK, contact power company or hydro authority. | |||||
|
|
| Defective motor. |
|
| Replace pump. |
|
|
| ||||
|
|
| Defective float switch. |
|
| Replace float switch. |
|
|
| ||||
|
|
| Float obstructed. |
|
| Remove obstruction. |
|
|
| ||||
Pump starts and stops |
| Backflow of water from piping. |
|
| Install or replace |
|
| ||||||
too often. |
| Faulty float switch. |
|
| Replace float switch. |
|
|
| |||||
|
|
|
|
|
|
|
| ||||||
Pump won’t shut off. |
| Defective float switch. |
|
| Replace float switch. |
|
|
| |||||
|
|
| Restricted discharge |
|
| Remove pump and clean pump and piping. | |||||||
|
|
| (obstacle in piping). |
|
|
|
|
|
|
|
| ||
|
|
| Float obstructed. |
|
| Remove obstruction. |
|
|
| ||||
Pump operates but |
| Low line voltage. |
|
| If voltage under recommended minimum, check size of wiring from main | ||||||||
delivers little or no water. |
|
|
|
|
|
| switch on property. If OK, contact power company or hydro authority. | ||||||
|
|
| Worn or plugged impeller. |
|
| Replace pump. |
|
|
| ||||
|
|
| Anti airlock vent hole is plugged. |
| Clean out the vent hole with a hat pin or pipe cleaner. | ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| REPAIR PARTS LIST |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
| Key No. |
| Part Description |
| Qty. |
|
|
|
|
|
| ||
| 1 |
|
| Power Cord |
| 1 |
|
|
| ||||
| 2 |
|
| Cover, Motor Assembly |
| 1 |
|
| ** |
| ** | ** |
|
| 3 |
|
| Inlet Screen |
| 1 |
|
|
|
| |||
| 4 |
|
| Switch Assembly |
| 1 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Replacement vertical switch must be mounted on discharge pipe.
**If the motor fails, replace the pump.
| |
|
|
4 | 4 |
1 | 1 |
2 | 2 |
3
3
5916 0109
5918 0109
For parts or assistance, call Simer Customer Service at