Page 19
SPI9000 Inverter Unit FI9 – FI14 User Manual
September 2006
Chapter 2 — Mounting
Dimensions
The inverter can be mounted in a vertical position on the back plane of a cubicle. Enough space must be reserved around the inverter to ensure sufficient cooling, see Figure 2-5. You must follow the minimum dimensions for installation, see Tables 2-5and 2-6. Also make sure that the mounting plane is relatively even. The inverter is fixed with four screws (or bolts, depending on the unit size). The following pages show the dimensions for the IP00 power module.
D1 | W1 |
| | H2 |
| | H1 |
| Dia. 1 | H3 |
| W2 |
| W2 |
Side | Front |
| Dia. 2 | |
D3 | D3 | |
D4 | D3 | |
| D2 | |
Bottom | Top |
Figure 2-1: SPI9000 FI9 Inverter Dimensions |
Table 2-1: SPI9000 FI9 Inverter Dimensions
| | | Approximate Dimensions in Inches (mm) | | | | | |
| | | | | | | | | | | | | |
| Inverters | Voltage | W1 | W2 | H1 | H2 | H3 | D1 | D2 | D3 | D4 | Dia. 1 | Dia. 2 |
| | | | | | | | | | | | | |
| | | | | | | | | | | | | |
| SPI100 – 170 | 480V/575V | 9.41 | 3.94 | 40.63 | 37.40 | 2.46 | 15.20 | 2.12 | 5.51 | 6.03 | .18 | .37 |
| | | (239) | (100) | (1032) | (950) | (62.5) | (386) | (53.9) | (140) | (153.1) | (4.6) | (9.5) |
| | | | | | | | | | | | | |
| | | | | | | | | | | | | |
MN04004002E | For more information visit: www.EatonElectrical.com | | | | | 2-1 |
Contents
SPI9000 Inverter Unit FI9 FI14
Page
Important Notice Please Read
Contents
List of Figures
SPI9000 Inverter Unit Block Diagram
List of Tables
25 HMI Acknowledge Timeout
Definitions and Symbols
Safety
Hazardous High Voltage
September
Vii
Motor and Equipment Safety
Grounding and ground fault protection
FI9 FI14 Inverter Unit Catalog Numbering System
Overview
I 0 1 6 a 0 4 a 1 N
Receiving and Inspection
Storage
Maintenance
Technical Data
Standard Features of SPI Inverter Units
SPI9000 Inverter Unit Block Diagram
380 500V AC, 50/60 Hz, Three-Phase Inverters Ratings
Power Ratings
Supply Voltage 465 800V DC, Motor Voltage 380 500V AC
Supply Voltage 640 1100V DC, Motor Voltage 525 690V AC
525 690V AC, 50/60 Hz, Three-Phase Inverters Ratings
Motor Connection
Control Characteristics
Technical Information
Description Specification Supply Connection
Control Connections
EMC at Default Settings
Safety
Description Specification Ambient Conditions
DC Currents for 640 1100V DC Supply Voltage
DC Currents for 465 800V DC Supply Voltage
Structure Inom Output Motor COS IDC Input
Approximate Dimensions in Inches mm Inverters Voltage Dia
Dimensions
Mounting
SPI9000 FI10 Inverter Dimensions
SPI9000 FI12 Inverter Dimensions
Frames FI9 to FI14
Fan Cooling
Installation Space
Required Cooling Air
Power Losses
Approximate Dimensions in Inches mm Frame Voltage
Mounting Space Requirements
FI9/FI10 Basic Wiring Diagram with Charging
Power Wiring
FI9/FI10 Basic Wiring Diagram without Charging
FI12 Basic Wiring Diagram with Charging
FI12 Basic Wiring Diagram without Charging
FI13 Basic Wiring Diagram with Charging
FI13 Basic Wiring Diagram without Charging
FI14 Basic Wiring Diagram with Charging
FI14 Basic Wiring Diagram without Charging
Fuses, 465 800V DC Inverters
Power Connections
DC Supply and Motor Cables
Cable Types Required to Meet Standards
Fuses Used in 640 1100V DC Inverters
Fuses, 640 1100V DC Inverters
Information about fuses
Cable Sizes for 380 500V AC
Inverter Supply and Motor Cables 380 500V AC
Terminal Sizes for 380 500V AC
Terminal Sizes 380 500V AC
Cable Sizes for 525 690V AC
Inverter Supply and Motor Cables 525 690V AC
Terminal Sizes for 525 690V AC
Terminal Sizes 525 690V AC
Cable Distances
Installation Instructions
Distance Between Cables Shielded Inches m Cable in Feet m
Frame Sizes
Tightening Torque
Cable Installation and the UL Standards
Cable and Motor Insulation Checks
Terminal Tightening Torques
September
Control Board
Control Wiring
Inverters Connected in Parallel
Control Wiring Details
Option Board A9 Wiring Diagram
Tightening Torques of Option Board Terminals
Control Cables
Terminal Screw Tightening Torque Lb-in
Galvanic Isolation Barriers
Galvanic Isolation Barriers
Terminal Signal Technical Information
Control I/O Terminal Signals on Option Board A9
Control I/O Terminal Signals on Option Board A2
Digital Input Signal Inversions
Control I/O Terminal Signals on Option Board A3
10 Jumper Blocks on Option Board A9
Jumper Selections on Option Board A9
11 Jumper Selection for Option Board A9
September
Menu Information
Indicators on the Keypad Display
Keypad Operation
Control Place Indicators
Drive Status Indicators
Drive Status Indicators
Control Place Indicators
Text Lines
Keypad Pushbuttons
Status LEDs Green Green Red
Status LEDs Green Green Red
Button Descriptions
Keypad Display Data
Menu Navigation
Keypad Navigation Chart
Monitoring Menu
Monitoring Menu M1
Parameter Menu M2
Monitored Signals
Keypad Control Menu M3
Parameter Value Change Procedure
Selection of Control Place Keypad Reference
Selection of Control Place
Keypad Direction
Active Faults Menu M4
Stop Button Activated
Fault Type Symbol Meaning
Fault Time Data Record
Data Units Description
Fault Time Recorded Data
Fault History Menu M5
Real Time Record
System Menu M6
10 Fault History Menu
10 System Menu Functions
Code Function Min Max Unit Default Cust Selections
10 System Menu Functions
11 Selection of Language Application Selection
Selection of Language
Parameter Sets S6.3.1
Copy Parameters
Upload parameters to keypad To keypad, S6.3.2
Download parameters to drive From keypad, S6.3.3
Automatic Parameter Backup P6.3.4
15 Parameter Comparison
Parameter Comparison
Password S6.5.1
Safety
Start-Up Wizard P6.5.3
Parameter Lock P6.5.2
Multimonitoring Items P6.5.4
Default Page P6.6.1
Backlight Time P6.6.5
Default page in the operating menu P6.6.2
Timeout Time P6.6.3
Contrast Adjustment P6.6.4
Internal Brake Resistor Connection P6.7.1
Hardware Settings
Fan Control P6.7.2
HMI Acknowledge Timeout P6.7.3
11 Counter Pages
Number of retries to receive HMI acknowledgement P6.7.4
System info
Total Counters
13 Software Information Pages
12 Resettable Counters
Trip Counters
Software S6.8.3
15 Hardware Information Pages
Applications S6.8.4
14 Applications Information Pages
Hardware S6.8.5
Expander Board Menu M7
Expander Boards S6.8.6
Further Keypad Functions
Code Parameter Min Max Default Cust Selections
September
Start-Up
Safety Precautions
Sequence of Operation
September
September
Table A-1 Fault Codes
Appendix a Fault Codes
Fault Code Possible Cause Solution
Eeprom
Programmable Faults only
Table A-1 Fault Codes
September MN04004002E
September
Page
Company Information