Troubleshooting
Problem |
| Possible Causes |
| Likely Solutions |
Tool will not start. | 1. | Cord not connected. | 1. | Check that cord is plugged in. |
| 2. | No power at outlet. | 2. | Check power at outlet. If outlet is unpowered, |
|
|
|
| turn off tool and check circuit breaker. If breaker |
|
|
|
| is tripped, make sure circuit is right capacity for |
|
|
|
| tool and circuit has no other loads. |
| 3. | Internal damage or wear. | 3. | Have technician service tool. |
|
| (Carbon brushes or switch, for |
|
|
|
| example.) |
|
|
Tool operates slowly. | Extension cord too long or wire size | Eliminate use of extension cord. If an extension | ||
| too small. | cord is needed, use shorter/heavier gauge cord. | ||
|
|
| See Extension Cords in GROUNDING section. | |
Performance | 1. Accessory dull or damaged. | 1. | Keep cutting accessories sharp. Replace as | |
decreases over time. |
|
|
| needed. |
| 2. | Carbon brushes worn or | 2. | Have qualified technician replace brushes. |
|
| damaged. |
|
|
Excessive noise or | 1. | Belt too loose (slipping) or too | 1. | Properly tension belt. |
rattling. |
| tight (bearing damage). |
|
|
| 2. | Internal damage or wear. |
|
|
|
| (Carbon brushes or bearings, for | 2. | Have technician service tool. |
|
| example.) |
|
|
Overheating. | 1. | Forcing material into blades too | 1. | Allow machine to work at its own rate. |
|
| fast. |
|
|
| 2. | Accessory misaligned. | 2. | Check and correct accessory to fence and/or |
|
|
|
| table alignment. |
| 3. | Accessory dull or damaged. | 3. | Keep cutting accessories sharp. Replace as |
|
|
|
| needed. |
| 4. | Blocked motor housing vents. | 4. | Wear |
|
|
|
| approved dust mask/respirator while blowing dust |
|
|
|
| out of motor using compressed air. |
| 5. | Motor being strained by long or | 5. | Eliminate use of extension cord. If an extension |
|
| small diameter extension cord. |
| cord is needed, use one with the proper diameter |
|
|
|
| for its length and load. See Extension Cords in |
|
|
|
| GROUNDING section. |
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.