Cisco Systems C819GUK9, C819HK9, C819G4GAK9 manual Installing the Router Ground Connection

Page 56

Chapter 2 Installing the Router

Installing the Router

Figure 2-8 Cisco 819 ISR Installed with the DIN Rail

282626

Installing the Router Ground Connection

The router must be connected to a reliable earth ground. Install the ground wire in accordance with local electrical safety standards.

For NEC-compliant grounding, use size 14 AWG (2 mm2) or larger copper wire and a ring terminal with an inner diameter of 1/4 in. (5 to 7 mm).

For EN/IEC 60950-compliant grounding, use size 18 AWG (1 mm2) or larger copper wire.

Warning This equipment needs to be grounded. Use a green and yellow 12 to 14 AWG ground wire to connect the host to earth ground during normal use. Statement 242

To install the ground connection, follow these steps:

Step 1 Strip one end of the ground wire to the length required for the terminal.

Step 2 Crimp the ground wire to the ring terminal using the wire crimper.

Step 3 If you choose to install the power switch lock, perform Step 5 to Step 7.

If you choose not to install power switch lock, perform Step 4 and Step 6 to Step 7.

Step 4 Attach the ring terminal to the chassis. Use the single screw provided. Tighten the screws to a torque of 8 to 10 inch-pound (0.9 to 1.1 newton meter). (See Figure 2-9.)

 

Cisco 819 Integrated Services Router Hardware Installation Guide

2-12

OL-23125-02

Image 56
Contents Americas Headquarters Text Part Number OL-23125-02Page N T E N T S Connecting a Terminal or PC to the Console Port Contents OL-23125-02 Objective AudienceChapter Name Description OrganizationConventions Bewaar Deze Instructies Warnung Wichtige SicherheitshinweiseAvvertenza Importanti Istruzioni Sulla Sicurezza Aviso Instruções Importantes DE SegurançaPage GEM Disse Anvisninger Page OL-23125-02 Page Related Documentation Searching Cisco DocumentsPreface OL-23125-02 Product Overview General DescriptionCisco 819HG Integrated Services Router Wlan LED3shows the front panel details of the Cisco 819HG ISR 4shows the front panel details of the Cisco 819HGW ISR SKU Information SKU IDSKU ID WiFi External Antenna Support DescriptionMode Frequency Band DescriptionHSPA+/HSPA Hardware Features Rebranding of C8xx-B and EHWIC-3G-EVDO-BGB Dram Platform Features for Cisco 819 ISRsMB Dram Antennas SnmpPower Switch Reset ButtonLEDs Color DescriptionRssi Wlan LED 7describes the 4G LTE LEDs for the Cisco 819 ISR Memory SIMEmbedded 3G Modem Embedded 4G LTE ModemSIM Card Two Internal SIM Card SlotsSupported Cisco Antennas and Cables 3G-ANTM-OUT-OM3G-ANTM-OUT-LP 3G-ACC-OUT-LAAIR-ANTM2050D-R AIR-ANT2430V-RAIR-ANT5140V-R AIR-ANT2440NV-RMaximum Gain Cisco Part Number Description Frequency Ranges AIR-CAB005LL-R AIR-CAB020LL-RAIR-CAB050LL-R Maximum Insertion4G-CAB-ULL-50 Serial Port4G-CAB-ULL-20 Power Supply AC Power AdapterAccessories Cisco Part Number AccessoryOL-23125-02 Installing the Router Equipment, Tools, and Connections Connections Items Shipped with your RouterAdditional Items Installing the Router Ethernet DevicesAccessing the SIM Card Installing Antennas Accessing the SIM CardsInstalling a WiFi External Antenna Installing the AntennaInstalling on a Table Mounting on a WallAttaching the Standard Brackets Installing a DIN Rail Installing the Router to the WallTurn the router sideways so that the antenna is at the top Installing the Router Ground Connection Cisco 819 ISR Installed with the DIN RailInstalling the Power Cord Retention Lock Chassis Ground Connection Using Ring Terminal10 Pre-assemble the O-Ring onto the Barrel Installing the Power Switch Lock 12 Installing Power Cord Lock onto the Router14 Installing Power Switch Lock Mounting the DC Power Supply 16 DC Power Supply Wall-Mounting FeaturesOL-23125-02 Preparing to Connect the Router Preventing Damage to the RouterConnecting a PC, Server, or Workstation Connecting an External Ethernet SwitchConnecting to an Ethernet Switch Connecting a Terminal or PC to the Console Port Connecting a Terminal or PC to the Console PortConnecting a Modem to the Console Port Terminal Emulator SettingsConnecting the AC Adapter Connecting the DC AdapterDC Power Supply PWR1-20W-12VDC and PWR1-20W-24VDC Verifying Connections LEDs to Check Normal PatternsCisco Configuration Professional Express Cisco IOS CLIUsername username privilege 15 secret 0 password Setup Command Facility Enter a hostname for the router this example uses RouterConfiguration is displayed Verifying the Initial Configuration OL-23125-02 Technical Specifications Router SpecificationsMaximum Power 11 W 20 W Consumption Transportation/Storage Conditions Martek Railway Power Adapters2 Mean Time Between Failure Ground Benign Environment SKUs Mtbf hoursSupported Power Adapters C819G+7-K9C819G-B-K9 Range 4G LTE SKUs 3GSKUsRange 4G LTE SKUs 3G SKUs 3G + WiFi SKUs C819HGW-S-A-K9C819HG-B-K9 C819HGW-V-A-K9 C819HG-S-K9 C819HGW+7-E-K9