Harbor Freight Tools 38123 operating instructions Symbology, See Figure C

Page 8

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.

(See Figure C.)

4.If using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Figure C.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Figure C.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 VOLT)

NAMEPLATE

 

EXTENSION CORD LENGTH

 

AMPERES

 

 

 

 

 

(At Full Load)

 

 

 

 

 

 

 

25

50

75

100

150

 

 

Feet

Feet

Feet

Feet

Feet

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

*Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

FIGURE C

SYMBOLOGY

 

Double Insulated

 

 

 

 

 

Canadian Standards

 

 

Association

 

 

 

 

 

Underwriters Laboratories,

 

 

Inc.

 

 

 

 

V ~

Volts Alternating Current

 

 

 

 

 

 

A

Amperes

 

 

 

 

 

 

noxxxx/min.

No Load Revolutions per

 

Minute (RPM)

FIGURE D

 

SKU 38123

For technical questions, please call 1-800-444-3353.

Page 8

Image 8
Contents For technical questions and replacement parts, please call 38123Specifications General Safety RulesSave this Manual Work AreaElectrical Safety Personal SafetyTool USE and Care ServiceSpecific Safety Rules Industrial applications must follow Osha requirements Grounding Grounded Tools Tools with Three Prong PlugsDouble Insulated Tools Tools with TWO Prong Plugs Extension CordsSymbology See Figure CAssembly Instructions To Secure The Sander Base Assembly To a WorkbenchTo Mount The Table Assembly UnpackingFigure F To Install The Backstop To Adjust The Worktable For Vertical SandingOperating Instructions See Figure G SKU For technical questions, please callSee Figure J To Level The Worktable AssemblySee Figure To Install And Adjust The Sanding Belt See Figure KON/OFF Locking Switch Sanding Methods Surface Sanding On The Sanding BeltSanding Methods End Sanding On The Sanding Belt Sanding Methods Sanding Curved EdgesTroubleshooting Symptom Probable Cause RemedyINSPECTION, MAINTENANCE, and Cleaning Do not use damaged equipmentTo replace the timing Drive Belt See Figure Q, nextPlease Read the Following Carefully See Figure QParts List Assembly Drawing