Sanyo SAP-K77RAX, Sanyo Split System Air Conditoner service manual R115H5A / 1,100W

Page 14

Outdoor Unit SAP-C127RAX

Control PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

Single Rotary

 

Compressor Model / Nominal Output

 

 

 

C-R115H5A / 1,100W

 

Compressor Oil ... Amount

 

 

CC

SAY-56T ... 520

 

Coil Resistance (Ambient Temp. 25 °C)

Ohm

C - R : 1.962

 

 

 

 

 

 

C - S : 5.38

 

 

 

 

 

 

 

 

Safety Device

Type

 

 

 

External (OLR)

 

 

Overload Relay

 

 

 

MRA98619-9200

 

 

Operating Temp.

Open

°C

150 +/- 5

 

 

 

Close

°C

69 +/- 11

 

 

Operating Amp. (Ambient Temp. 25 °C)

Trip in 6 to 16 sec. at 22.5A

 

Run Capacitor

 

 

 

Micro F

25

 

 

 

 

 

VAC

400

 

Crankcase Heater

 

 

 

-

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

Propeller

 

Q'ty ... Dia.

 

 

 

mm

1 ... D380

 

 

 

 

 

 

Fan Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

AC Motor

 

Model ... Q'ty

 

 

 

 

IB-976-501E ... 1

 

No. of Poles

 

 

 

 

6

 

Rough Measure RPM (Cool)

 

 

 

840

 

Nominal Output

 

 

 

W

25

 

Coil Resistance

 

 

 

Ohm

BRN - WHT : 213

 

(Ambient Temp. 20 °C)

 

 

 

RED (PNK) - WHT : 168

 

 

 

 

 

 

 

 

Safety Device

Type

 

 

 

Thermal protector

 

 

Operating Temp.

 

Open

°C

110

 

 

 

 

Close

°C

75

 

Run Capacitor

 

 

 

Micro F

2.5

 

 

 

 

 

VAC

450

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

 

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

 

 

 

1

 

Fin Pitch

 

 

 

mm

1.3

 

Face Area

 

 

 

m2

0.346

 

 

 

 

 

 

External Finish

 

 

 

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

14

Image 14
Contents Split System AIR Conditioner Please Read Before Starting Table of Contents Appendix Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeOutdoor Unit Unit SpecificationsIndoor Unit SAP-K97RAX SAP-K127RAX Outdoor Unit SAP-C127RAXMajor Component Specifications Indoor Unit SAP-K77RAXIndoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Outdoor Unit Outdoor Unit SAP-C77RAXOutdoor Unit SAP-C97RAX R115H5A / 1,100W Other Component Specifications Power Relay Model Rating EL200/240A1-F M AC277V 30ADimensional Data Unit mm 370 Refrigerant Flow Diagram Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAXPerformance charts Performance DataTemp. C Current Indoor Unit SAP-K127RAX Outdoor Unit SAP-C127RAX Air Throw Distance Charts Indoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Single Phase 50 Hz Cooling Capacity55 kW 460 m 3/h Electrical Characteristics Electrical DataElectric Wiring Diagrams Controller8FA2-5250-29800-0 Installation Instructions Installation Site SelectionOutdoor Unit AvoidRecommended Wire Length and Diameter Remote Control Unit Installation Position Mounting on a WallHow to Test Run the Air Conditioner How to replace the grille Removing and Installing the GrilleHow to remove the grille Address Setting of the Remote Control Unit Room Temperature Control CoolingDry a zone Dry Operation DehumidificationCooling operation Dry B zoneSet Speed Freeze Prevention Cooling and DryAt least approx min Sec Automatic Fan Speed Cooling and Dry Troubleshooting Check before and after troubleshootingCheck outdoor unit Air conditioner does not operateCircuit breaker trips or fuse blows Check indoor unitThere is a possibility of short circuit Power is not suppliedNeither indoor nor outdoor unit runs Check fuse on the indoor P.C.Board Check remote control unitCheck Timer on the remote control unit Check setting temperature Only outdoor unit does not runOnly flap motor does not run Some part of air conditioner does not operateOnly indoor fan does not run Only outdoor fan does not runOnly compressor does not run Excessive cooling Air conditioner operates, but abnormalities are observedPoor cooling Indoor Unit Power Supply CordMeasurement of Insulation Resistance Measurement of Insulation Resistance for Electrical PartsChecking Continuity of Fuse on PCB Assy Checking Motor CapacitorOI-852-6-4181-018-00-1 Features ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Jumper wire for address switching Temperature setting buttons TempCancel button Back side of remote control unit Cover removedACL button Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control UnitManual fan speed Operation with the Remote Control UnitAutomatic fan speed Economy Mode Timer setting Using the 12-HOUR on and OFF TimerTimer times appear in the display for only 3 seconds HoursDo not Using the 1-HOUR OFF TimerTips for Energy Saving Stop Operate Hour HoursButton ON/OFF Adjusting the Airflow DirectionKnob Care and Cleaning Troubleshooting Operating RangeCenter manual