Sanyo SAP-K77RAX service manual Unit Specifications, Indoor Unit, Outdoor Unit

Page 6

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit

SAP-K77RAX

 

 

 

 

 

 

Outdoor Unit

SAP-C77RAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Source

 

 

 

 

 

220 to 240V Single-Phase 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

220-240 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

Cooling

 

Capacity

 

 

 

kW

 

 

2.10 / 2.10 / 2.10

 

 

 

 

 

BTU/h

 

 

7,200 / 7,200 / 7,200

 

Air Circulation (High)

 

 

m3/h

 

 

430

 

Moisture Removal (High)

 

Liters/h

 

 

1.1

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

 

Cooling

 

Available Voltage Range

 

V

 

 

198 to 264

 

Running Amperes

 

 

A

 

 

3.5 / 3.6 / 3.6

 

Power Input

 

 

 

W

 

 

750 / 770 / 790

 

Power Factor

 

 

%

 

 

97 / 93 / 91

 

E.E.R.

 

 

 

W/W

 

 

2.80 / 2.73 / 2.66

 

C.O.P.

 

 

 

W/W

 

 

-

 

Compressor Locked Rotor Amperes

 

A

 

 

16.5

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature Control

 

 

 

Microprocessor / I.C. Thermister

 

Control Unit

 

 

 

 

 

Wireless Remote Control Unit

 

Timer

 

 

 

 

 

12-Hour ON or OFF Timer, 1Hour OFF Timer

 

Fan Speeds

 

 

Indoor / Outdoor

 

Auto and 3 steps / 1 (Hi)

 

Airflow Direction (Indoor)

 

Horizontal

 

 

Manual

 

 

 

 

 

Vertical

 

 

Auto

 

Air Filter

 

 

 

 

 

Washable, Anti-Mold

 

Compressor

 

 

 

 

 

 

Single Rotary

 

Refrigerant / Amount charged at shipment

kg

 

 

R22 / 0.48

 

Refrigerant Control

 

 

 

 

 

Capillary tube

 

Operation Sound

Indoor : Hi/Me/Lo

dB-A

 

 

38 / 33 / 30

 

 

 

Outdoor : Hi

 

dB-A

 

 

49

 

Refrigerant Tubing Connections

 

 

 

 

Flare Type

 

Max. allowable tubing length at shipment

m

 

 

5

 

Refrigerant

 

Narrow tube

 

mm (in.)

 

 

6.35 (1/4)

 

Tube Diameter

Wide tube

 

mm (in.)

 

 

9.52 (3/8)

 

Refrigerant Tube Kit / Accessories

 

 

 

Optional / Air Clean Filter

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

Unit Dimensions

Height

 

mm

 

250

 

446

 

 

 

Width

 

mm

 

799

 

660

 

 

 

Depth

 

mm

 

205

 

240

 

Package Dimensions

Height

 

mm

 

270

 

491

 

 

 

Width

 

mm

 

870

 

775

 

 

 

Depth

 

mm

 

295

 

340

 

Weight

 

Net

 

kg

 

7.5

 

21

 

 

 

Shipping

 

kg

 

9.0

 

22

 

Shipping Volume

 

 

m3

 

0.06

 

0.13

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are:

 

 

 

 

 

 

 

Cooling: Indoor air temperature

27°C D.B. / 19°C W.B.

 

 

 

 

 

Outdoor air temperature

35°C D.B. / 24°C W.B.

 

 

 

6

Image 6
Contents Split System AIR Conditioner Please Read Before Starting Table of Contents Appendix Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeUnit Specifications Indoor UnitOutdoor Unit SAP-K97RAX SAP-K127RAX Outdoor Unit SAP-C127RAXMajor Component Specifications Indoor Unit SAP-K77RAXIndoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Outdoor Unit Outdoor Unit SAP-C77RAXOutdoor Unit SAP-C97RAX R115H5A / 1,100W Other Component Specifications Power Relay Model Rating EL200/240A1-F M AC277V 30ADimensional Data Unit mm 370 Refrigerant Flow Diagram Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAXPerformance charts Performance DataTemp. C Current Indoor Unit SAP-K127RAX Outdoor Unit SAP-C127RAX Air Throw Distance Charts Indoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Single Phase 50 Hz Cooling Capacity55 kW 460 m 3/h Electrical Characteristics Electrical DataElectric Wiring Diagrams Controller8FA2-5250-29800-0 Installation Instructions Installation Site SelectionOutdoor Unit AvoidRecommended Wire Length and Diameter Remote Control Unit Installation Position Mounting on a WallHow to Test Run the Air Conditioner Removing and Installing the Grille How to remove the grilleHow to replace the grille Address Setting of the Remote Control Unit Room Temperature Control CoolingDry a zone Dry Operation DehumidificationCooling operation Dry B zoneFreeze Prevention Cooling and Dry At least approx min SecSet Speed Automatic Fan Speed Cooling and Dry Troubleshooting Check before and after troubleshootingCheck outdoor unit Air conditioner does not operateCircuit breaker trips or fuse blows Check indoor unitPower is not supplied Neither indoor nor outdoor unit runsThere is a possibility of short circuit Check remote control unit Check Timer on the remote control unitCheck fuse on the indoor P.C.Board Check setting temperature Only outdoor unit does not runOnly flap motor does not run Some part of air conditioner does not operateOnly indoor fan does not run Only outdoor fan does not runOnly compressor does not run Air conditioner operates, but abnormalities are observed Poor coolingExcessive cooling Indoor Unit Power Supply CordMeasurement of Insulation Resistance Measurement of Insulation Resistance for Electrical PartsChecking Continuity of Fuse on PCB Assy Checking Motor CapacitorOI-852-6-4181-018-00-1 Features ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Jumper wire for address switching Temperature setting buttons TempCancel button Back side of remote control unit Cover removedACL button Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control UnitOperation with the Remote Control Unit Automatic fan speedManual fan speed Economy Mode Timer setting Using the 12-HOUR on and OFF TimerTimer times appear in the display for only 3 seconds HoursDo not Using the 1-HOUR OFF TimerTips for Energy Saving Stop Operate Hour HoursAdjusting the Airflow Direction KnobButton ON/OFF Care and Cleaning Troubleshooting Operating RangeCenter manual