OPERATION WITH THE REMOTE CONTROL UNIT

1. Operation

STEP 2

STEP 1

STEP 3

STEP 5

STEP 4

NOTE

Check that the circuit breaker on the power panel is

 

 

turned on.

 

 

 

 

 

 

Press the setting buttons as described below and

 

 

change the settings as desired.

 

 

 

 

 

 

STEP 1 Press the MODE selector button and

 

 

select the desired mode.

 

 

 

For cooling operation

 

 

For dehumidifying operation

 

 

For fan only operation

 

 

 

 

 

STEP 2 To start the air conditioner, press the ON/

 

 

OFF operation button.

 

 

 

 

 

 

STEP 3 Press the TEMP. setting buttons to

 

 

change the temperature setting to the

 

 

desired temperature. The set temperature

 

 

appears in the display for only 3 seconds.

 

 

Adjustable temperature range:

30°C max.

16°C min.

STEP 4 Set the FAN SPEED selector button to the setting you want.

STEP 5 Press the FLAP button and set the airflow direction as desired.

(Refer to “ADJUSTING THE AIRFLOW DIRECTION” on page 13.)

To stop the air conditioner, press the ON/OFF operation button again.

NOTE • Choose the best position in the room for the remote control unit, which also transmits the operating instructions. Once you’ve found this best position, always keep the remote control unit there.

This appliance has a built-in 5-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop.

2. Adjusting the Fan Speed

A. Automatic fan speed

Simply set the FAN SPEED selector button to the position.

This automatically sets the best fan speed for the room temperature.

B. Manual fan speed

If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired. [ , , or ]

3. Fan Only

STEP 2

STEP 1

STEP 3

If you want to circulate air without any temperature control, follow these steps:

STEP 1

Press the MODE selector button to switch

 

to the fan mode

.

 

 

STEP 2

Press the ON/OFF operation button.

STEP 3 Press the FAN SPEED selector button to select the fan speed of your choice ( , or ).

OI-018-9-EG

9

 

Image 61
Contents Split System AIR Conditioner Please Read Before Starting Table of Contents Appendix Operating Range Temperature Indoor Air Intake Temp Outdoor Air Intake TempIndoor Unit Unit SpecificationsOutdoor Unit SAP-K97RAX Outdoor Unit SAP-C127RAX SAP-K127RAXIndoor Unit SAP-K77RAX Major Component SpecificationsIndoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Outdoor Unit SAP-C77RAX Outdoor UnitOutdoor Unit SAP-C97RAX R115H5A / 1,100W Power Relay Model Rating EL200/240A1-F M AC277V 30A Other Component SpecificationsDimensional Data Unit mm 370 Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAX Refrigerant Flow DiagramPerformance Data Performance chartsTemp. C Current Indoor Unit SAP-K127RAX Outdoor Unit SAP-C127RAX Air Throw Distance Charts Indoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Cooling Capacity Single Phase 50 Hz55 kW 460 m 3/h Electrical Data Electrical CharacteristicsController Electric Wiring Diagrams8FA2-5250-29800-0 Installation Site Selection Installation InstructionsAvoid Outdoor UnitRecommended Wire Length and Diameter Mounting on a Wall Remote Control Unit Installation PositionHow to Test Run the Air Conditioner How to remove the grille Removing and Installing the GrilleHow to replace the grille Address Setting of the Remote Control Unit Cooling Room Temperature ControlCooling operation Dry Operation DehumidificationDry a zone Dry B zoneAt least approx min Sec Freeze Prevention Cooling and DrySet Speed Automatic Fan Speed Cooling and Dry Check before and after troubleshooting TroubleshootingCircuit breaker trips or fuse blows Air conditioner does not operateCheck outdoor unit Check indoor unitNeither indoor nor outdoor unit runs Power is not suppliedThere is a possibility of short circuit Check Timer on the remote control unit Check remote control unitCheck fuse on the indoor P.C.Board Only outdoor unit does not run Check setting temperatureOnly indoor fan does not run Some part of air conditioner does not operateOnly flap motor does not run Only outdoor fan does not runOnly compressor does not run Poor cooling Air conditioner operates, but abnormalities are observedExcessive cooling Measurement of Insulation Resistance Power Supply CordIndoor Unit Measurement of Insulation Resistance for Electrical PartsChecking Motor Capacitor Checking Continuity of Fuse on PCB AssyOI-852-6-4181-018-00-1 Contents FeaturesInstallation Location Alert SymbolsSafety Instructions Product InformationUnit Display and Operation Button Names of PartsSymbols Remote Control Unit DisplayRemote Control Unit Cancel button Temperature setting buttons TempJumper wire for address switching Back side of remote control unit Cover removedAir conditioner Indoor unit Receiver Remote control Using the Remote Control UnitACL button UnitAutomatic fan speed Operation with the Remote Control UnitManual fan speed Economy Mode Timer times appear in the display for only 3 seconds Using the 12-HOUR on and OFF TimerTimer setting HoursTips for Energy Saving Using the 1-HOUR OFF TimerDo not Stop Operate Hour HoursKnob Adjusting the Airflow DirectionButton ON/OFF Care and Cleaning Operating Range TroubleshootingCenter manual