Sanyo Sanyo Split System Air Conditoner Using the 12-HOUR on and OFF Timer, Timer setting, Hours

Page 63

USING THE 12-HOUR ON AND OFF TIMER

1. TIMER ON mode (Example)

The timer times appear in the display for only 3 seconds.

STEP 1

STEP 2

STEP 3

After the length of time set for TIMER ON elapses, the unit begins operating.

The display depicted above indicates that the air conditioner will begin operating in three hours.

Setting procedure:

STEP 1

Press the MODE button and set the desired

 

operation mode.

 

 

 

(See ‘‘Operation with the Remote Control Unit,’’

 

page 9.)

 

 

 

 

 

STEP 2

Press the TIMER ON button.

 

 

 

STEP 3

Press the TIMER ON button (which advances the

 

time displayed) to set the time at which you want

 

operation to begin.

 

 

 

The time can be set for one to twelve hours, in one

 

hour steps.

 

 

 

1

2

3.......12

After the length of time set for TIMER OFF elapses, the unit stops operating.

The display depicted at left indicates that the air conditioner will stop operating in five hours.

Setting procedure:

STEP 1

Press the TIMER OFF button.

 

 

 

STEP 2

Press the TIMER OFF button (which advances the

 

time displayed) to set the time at which you want

 

operation to stop.

 

 

 

The time can be set for one to twelve hours, in one

 

hour steps.

 

 

 

1

2

3.......12

 

 

 

 

The display changes immediately to its status previous to timer

setting, but the indication remains.

To check the status of the timer while it is counting down, press the TIMER OFF button again.

Cancellation procedure: Press the CANCEL button.

3. ON/OFF Program Timer

A combination of the TIMER ON and TIMER OFF modes, this function allows you to specify the time that the unit turns on and the time when it turns off.

(Example) The unit will turn on three hours from now, and turn off five hours from now.

TIMER ON

Timer setting

The display changes immediately to its status previous to timer

setting, but the indication remains.

To check the status of the timer while it is counting down, press the TIMER ON button again.

Cancellation procedure:Press the CANCEL button.

NOTE

If you do not operate the remote control unit for 25 hours or more after the start of ON timer operation, the unit will stop operating automatically as a safety measure in case you forget to turn off the air conditioner.

2. TIMER OFF mode (Example)

The timer times appear in the display for only 3 seconds.

STEP 1

STEP 2

display duringStopOperate counting

 

3 hours

2 hours

TIMER OFF

 

 

5 hours

 

display during

 

 

counting after

 

 

3 hours has

 

 

elapsed

 

 

Setting procedure:

STEP 1

Use the procedure described in the ‘‘1. TIMER ON

 

mode’’ section on the preceding page to set the timer

 

to turn the unit on three hours from now.

 

 

STEP 2

Use the procedure described in the ‘‘2. TIMER OFF

 

mode’’ section on the preceding page to set the timer

 

to turn the unit off five hours from now.

 

 

The display changes immediately to its status previous to timer

setting, but the or indication remains.

Press the TIMER ON button or the TIMER OFF button to display the time remaining on the timer in seconds.

Note that it is not possible to check both the ON and OFF timer settings. The timer setting that will occur first is given preference and displayed.

Cancellation procedure: Press the CANCEL button.

OI-018-11-EG

11

 

Image 63
Contents Split System AIR Conditioner Please Read Before Starting Table of Contents Appendix Operating Range Temperature Indoor Air Intake Temp Outdoor Air Intake TempUnit Specifications Indoor UnitOutdoor Unit SAP-K97RAX Outdoor Unit SAP-C127RAX SAP-K127RAXIndoor Unit SAP-K77RAX Major Component SpecificationsIndoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Outdoor Unit SAP-C77RAX Outdoor UnitOutdoor Unit SAP-C97RAX R115H5A / 1,100W Power Relay Model Rating EL200/240A1-F M AC277V 30A Other Component SpecificationsDimensional Data Unit mm 370 Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAX Refrigerant Flow DiagramPerformance Data Performance chartsTemp. C Current Indoor Unit SAP-K127RAX Outdoor Unit SAP-C127RAX Air Throw Distance Charts Indoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Cooling Capacity Single Phase 50 Hz55 kW 460 m 3/h Electrical Data Electrical CharacteristicsController Electric Wiring Diagrams8FA2-5250-29800-0 Installation Site Selection Installation InstructionsAvoid Outdoor UnitRecommended Wire Length and Diameter Mounting on a Wall Remote Control Unit Installation PositionHow to Test Run the Air Conditioner Removing and Installing the Grille How to remove the grilleHow to replace the grille Address Setting of the Remote Control Unit Cooling Room Temperature ControlDry B zone Dry Operation DehumidificationCooling operation Dry a zoneFreeze Prevention Cooling and Dry At least approx min SecSet Speed Automatic Fan Speed Cooling and Dry Check before and after troubleshooting TroubleshootingCheck indoor unit Air conditioner does not operateCircuit breaker trips or fuse blows Check outdoor unitPower is not supplied Neither indoor nor outdoor unit runsThere is a possibility of short circuit Check remote control unit Check Timer on the remote control unitCheck fuse on the indoor P.C.Board Only outdoor unit does not run Check setting temperatureOnly outdoor fan does not run Some part of air conditioner does not operateOnly indoor fan does not run Only flap motor does not runOnly compressor does not run Air conditioner operates, but abnormalities are observed Poor coolingExcessive cooling Measurement of Insulation Resistance for Electrical Parts Power Supply CordMeasurement of Insulation Resistance Indoor UnitChecking Motor Capacitor Checking Continuity of Fuse on PCB AssyOI-852-6-4181-018-00-1 Contents FeaturesProduct Information Alert SymbolsInstallation Location Safety InstructionsUnit Display and Operation Button Names of PartsSymbols Remote Control Unit DisplayRemote Control Unit Back side of remote control unit Cover removed Temperature setting buttons TempCancel button Jumper wire for address switchingUnit Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control ACL buttonOperation with the Remote Control Unit Automatic fan speedManual fan speed Economy Mode Hours Using the 12-HOUR on and OFF TimerTimer times appear in the display for only 3 seconds Timer settingStop Operate Hour Hours Using the 1-HOUR OFF TimerTips for Energy Saving Do notAdjusting the Airflow Direction KnobButton ON/OFF Care and Cleaning Operating Range TroubleshootingCenter manual