Sanyo SAP-K77RAX service manual Using the 1-HOUR OFF Timer, Tips for Energy Saving, Do not

Page 64

USING THE 1-HOUR OFF TIMER

1. 1-Hour OFF Timer

This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.

The indicator in the display indicates that this function is operating.

Setting procedure:

Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button.

appears in the display.

Cancellation procedure:

Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.

The 1-Hour Timer function is now cancelled and the unit operates normally.

NOTE

If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.

It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later.

Do not use the 1-Hour OFF Timer when both TIMER ON and TIMER OFF are set simultaneously. If the 1-Hour OFF Timer has been set, press the TIMER OFF button, then the CANCEL button to operate both the 1-Hour OFF Timer and ON Timer simultaneously.

2.Combining the 1-Hour OFF Timer and 12-Hour ON Timer

By combining the 1-Hour OFF Timer and 12-Hour ON Timer, it is possible to have the unit operate for just one hour from the present time, and then have it switch on again later at a time specified by you.

(Example) Having the unit operate for just one hour from the present time, and then switch on again three hours from the present time.

Timer setting

 

 

 

 

 

 

 

 

 

 

 

Operate

 

Stop

 

Operate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 hour

 

2 hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 hours

 

 

 

 

Setting procedure:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 1

Press the 1 HR. TIMER button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 2

Press the TIMER ON button. Then press it again to

 

 

set the unit to turn on three hours later.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

Set the 1-Hour OFF Timer and the 12-Hour ON Timer simultaneously.

Unless you set the 1-Hour OFF Timer and the 12-Hour ON Timer at the same time, the 1-Hour OFF Timer may operate for one hour or more.

TIPS FOR ENERGY SAVING

Do not

Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged.

Let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.

Do

Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

12

OI-018-12-EG

 

Image 64
Contents Split System AIR Conditioner Please Read Before Starting Table of Contents Appendix Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeIndoor Unit Unit SpecificationsOutdoor Unit SAP-K97RAX SAP-K127RAX Outdoor Unit SAP-C127RAXMajor Component Specifications Indoor Unit SAP-K77RAXIndoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Outdoor Unit Outdoor Unit SAP-C77RAXOutdoor Unit SAP-C97RAX R115H5A / 1,100W Other Component Specifications Power Relay Model Rating EL200/240A1-F M AC277V 30ADimensional Data Unit mm 370 Refrigerant Flow Diagram Indoor Unit SAP-K77RAX Outdoor Unit SAP-C77RAXPerformance charts Performance DataTemp. C Current Indoor Unit SAP-K127RAX Outdoor Unit SAP-C127RAX Air Throw Distance Charts Indoor Unit SAP-K97RAX Indoor Unit SAP-K127RAX Single Phase 50 Hz Cooling Capacity55 kW 460 m 3/h Electrical Characteristics Electrical DataElectric Wiring Diagrams Controller8FA2-5250-29800-0 Installation Instructions Installation Site SelectionOutdoor Unit AvoidRecommended Wire Length and Diameter Remote Control Unit Installation Position Mounting on a WallHow to Test Run the Air Conditioner How to remove the grille Removing and Installing the GrilleHow to replace the grille Address Setting of the Remote Control Unit Room Temperature Control CoolingDry Operation Dehumidification Cooling operationDry a zone Dry B zoneAt least approx min Sec Freeze Prevention Cooling and DrySet Speed Automatic Fan Speed Cooling and Dry Troubleshooting Check before and after troubleshootingAir conditioner does not operate Circuit breaker trips or fuse blowsCheck outdoor unit Check indoor unitNeither indoor nor outdoor unit runs Power is not suppliedThere is a possibility of short circuit Check Timer on the remote control unit Check remote control unitCheck fuse on the indoor P.C.Board Check setting temperature Only outdoor unit does not runSome part of air conditioner does not operate Only indoor fan does not runOnly flap motor does not run Only outdoor fan does not runOnly compressor does not run Poor cooling Air conditioner operates, but abnormalities are observedExcessive cooling Power Supply Cord Measurement of Insulation ResistanceIndoor Unit Measurement of Insulation Resistance for Electrical PartsChecking Continuity of Fuse on PCB Assy Checking Motor CapacitorOI-852-6-4181-018-00-1 Features ContentsAlert Symbols Installation LocationSafety Instructions Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Temperature setting buttons Temp Cancel buttonJumper wire for address switching Back side of remote control unit Cover removedUsing the Remote Control Unit Air conditioner Indoor unit Receiver Remote controlACL button UnitAutomatic fan speed Operation with the Remote Control UnitManual fan speed Economy Mode Using the 12-HOUR on and OFF Timer Timer times appear in the display for only 3 secondsTimer setting HoursUsing the 1-HOUR OFF Timer Tips for Energy SavingDo not Stop Operate Hour HoursKnob Adjusting the Airflow DirectionButton ON/OFF Care and Cleaning Troubleshooting Operating RangeCenter manual