Sanyo XMS1272 Using the 1-HOUR OFF Timer, Tips for Energy Saving, Adjusting the Airflow Direction

Page 51

USING THE 1-HOUR OFF TIMER

1. 1-Hour OFF Timer

This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.

The indicator in the display indicates that this function is operating.

Setting procedure:

Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button.

appears in the display.

Cancellation procedure:

Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.

The 1-Hour Timer function is now cancelled and the unit operates normally.

NOTE

If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.

It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later.

2.Operation together with the daily ON/OFF repeat timer

The 1-Hour OFF Timer setting is given priority over the DAILY ON/ OFF REPEAT setting.

TIPS FOR ENERGY SAVING

Do not

Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged.

Let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.

Do

Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

ADJUSTING THE AIRFLOW DIRECTION

The vertical airflow can be adjusted by moving the flap with the remote control unit. Do not move the flap with your hands. Confirm that the remote control unit has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.

A. Sweep function

The flap starts moving up and down to deliver air over the sweep range.

B. Setting the airflow manually

 

SWEEP

Referring to the above

 

illustration, use the

COOL

 

FLAP button to set the

DRY

SWEEP

airflow direction within

 

 

the range used during

 

FAN

the cooling or

 

 

 

dehumidifying operation.

 

C. Auto flap function

The flap is set to the recommended position.

NOTE

The flap automatically closes when the unit is off.

CAUTION

Use the FLAP button on the remote control unit to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote control unit and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again.

Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down.

12

OI-141-12-EG

 

Image 51
Contents 17,500BTU / h 11,900BTU / hSafety Precautions Prohibit Table of Contents STK-RCS-7TWSUA Applicable MULTI-OUTDOOR Units Indoor Air Intake Temp Outdoor Air Intake Temp Operating RangeSpecifications Unit SpecificationsIndoor Unit XMS0972 & PNR-XS1872 Indoor Unit XMS0972 & PNR-XS1872208V XMS1272 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS1872 XS1872 & PNR-XS1872 Indoor Unit Panel Major Component SpecificationsIndoor Unit Indoor Unit Body XMS0972Indoor Unit Body XMS1272 Indoor Unit Body XS1872 ModelPT2M-51H-S3 Other Component SpecificationsModelKTEC-35-S98 Indoor heat exchanger sensor534 Dimensional DataRefrigerant Flow Diagram Refrigerant Flow DiagramIndoor Unit XS1872 & PNR-XS1872 Indoor unit Electrical Data 5250-469008FA2 Remove the air intake grill MaintenanceDisassembly Procedure Disconnect the connectors in the control boxRemove the ceiling panel Remove the power box and control box Remove the indoor air temperature sensorScrew Ground cable CN07 ScrewCN03 CN09 CN06 Remove the main body lower section Remove the heat exchanger sensor Remove the drain pump and float switchRemove the heat exchanger Remove the turbo fan and fan motorPAM- control FunctionsOperation Functions Emergency operationLamp colors Timer backupFreeze prevention Protective FunctionsTroubleshooting Precautions before Performing Inspection or RepairMethod of Self-Diagnostics Self-diagnostics Lamps Replace the circuit board or the fuse Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the controllerCondition E01 Serial Communication Error Identification ProcedureBefore the Operation Off Blinking IlluminatedTerminal board Outdoor Unit Condition E12 Indoor Fan Motor Trouble Diagnosis of Fan MotorLocations most susceptible to noise Trouble Correction Noise Malfunction and Electromagnetic InterferenceNoise malfunction Electromagnetic interferenceXMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 Pub. OI-85264181141000 Sanyo Mode D’EMPLOIContents FeaturesProduct Information Alert SymbolsInstallation Location Safety InstructionsUnit Display and Operation Button Names of PartsSymbols Remote Control Unit DisplayRemote Control Unit Sensor HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp Mode selector buttonUsing the Remote Control Unit Operation with the Remote Control Unit Automatic fan speedManual fan speed How it works? Setting the TimerCooling and DRY Mode Special Remarks1030 pm 710 am 1100 am Present time Operation IndicationDo not Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Tips for Energy SavingCleaning the main unit and remote control unit Care and CleaningWhen the air conditioner is not running Cleaning the flapsCare After a prolonged idle period How to remove the filterHow to remove the air intake grille Air filterTroubleshooting Wired Remote ControllerOperating Range XS1872 & PNR-XS1872 Pub. OI-85264181108001 Sanyo XS1271 XS1872OI-108-2-EG Important Multiple use is applied for the model XS1872 only OI-108-4-EG OI-108-5-EG OI-108-6-EG OI-108-7-EG OI-108-8-EG OI-108-9-EG OI-108-10-EG OI-108-11-EG OI-108-12-EG OI-108-13-EG OI-108-14-EG OI-108-15-EG Appendix C Installation Instructions For Indoor Unit Contents…In a Room For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a Ceiling or WallOptional Copper Tubing Kit Tools Required for Installation not suppliedAccessories Supplied with Unit Table GeneralAdditional Materials Required for Installation Installation Site SelectionH1, H2, H3, H4 Embedding the Tubing and WiringPlacing the Unit Inside the Ceiling How to Install the Indoor UnitPreparation for Suspending Suspending the Indoor UnitFastener is on the side Installing the Drain PipingDo not install an air bleeder as Attach so that the hose band10a Checking the DrainageIndoor unit Gaps Ceiling surface Ceiling panel Installing the Ceiling PanelAttaching the air-intake grille Wiring the Ceiling Panel and the IndicatorWiring Instructions General precautions on wiring Checking After InstallationWhen Removing the Ceiling Panel for Servicing Adjusting the Auto FlapHow to connect wiring to the terminal For Indoor Unit For Outdoor Unit For solid core wiring or F-cableFor stranded wiring How to Test Run the Air Conditioner Mounting on a Wall Remote Control Unit Installation PositionRear side Remote control unit mount To take out the remote control unit, pull it forwardAddress Setting of the Remote Control Unit Address SwitchInstallation Check Sheet Connecting a Home Automation DeviceSTK-RCS-7TWSUA Pub. OI-85264181139000 Sanyo STK-RCS-7TWSUADo not cool or heat the room too much Hot Start Heating System SET button Timer and Present Time setting buttonsAuto Timer Select buttonAutomatic Operation Only for COOL/DRY/HEAT Model Heating Mode Only for COOL/DRY/HEAT Model Remote Control Unit DisplayProgrammed Daily on / OFF910 pm 710 am 1130 pm Present time Sweep Cool Drysweep Heat FAN Appendix E Installation Instructions STK-RCS-7TWSUA Installation location Parts supplied with the remote controllerRemote controller installation guidelines How to install the remote controllerInstalling directly onto the wall Installing with in-wall junction boxHow to wire the remote controller ON/OFF

XMS1272, XMS0972 specifications

The Sanyo XMS0972 and XMS1272 are remarkable air conditioning units that blend efficiency with cutting-edge technology. Designed for residential and commercial spaces, these models promise comfort while optimizing energy consumption.

One of the standout features of both the XMS0972 and XMS1272 is their advanced inverter technology. This feature allows the units to adjust their cooling capacity based on the room's ambient temperature. As a result, the air conditioners can maintain a consistent temperature without the frequent on/off cycles associated with traditional units. This not only ensures a more stable climate but also significantly reduces energy consumption, making them eco-friendly options.

Another significant characteristic is the Quiet Operation mode. Both models are engineered with noise reduction technology, providing a tranquil environment for users. This is particularly beneficial for bedrooms, offices, or libraries where noise levels can be a concern. The XMS models operate at a whisper-quiet level, allowing users to focus on their tasks or enjoy a peaceful night's sleep without disruption.

The Sanyo XMS0972 and XMS1272 also feature a user-friendly digital interface. With an intuitive remote control and an easy-to-read display, setting your desired temperature or switching modes has never been easier. Moreover, the smart diagnostic capability allows for quick troubleshooting, helping to identify any issues to ensure peak performance throughout their lifespan.

Both models are equipped with a 24-hour timer, adding convenience for users who wish to come home to a pre-cooled or heated environment. This feature enhances comfort and saves energy when the unit is not in use.

In terms of design, the Sanyo XMS units boast a sleek and modern aesthetic that seamlessly integrates into various interior styles. Their compact size allows for flexible installation options, making them suitable for various living and working spaces.

The XMS line also emphasizes air purification, incorporating advanced filters that capture dust, allergens, and other pollutants. This results in not just temperature control but also improved air quality, contributing to a healthier living environment.

In conclusion, the Sanyo XMS0972 and XMS1272 air conditioning units stand out for their energy efficiency, quiet operation, user-friendly features, and air purification capabilities. These characteristics make them an ideal choice for individuals and businesses looking for reliable and sophisticated climate control solutions.