Sanyo XMS0972, XMS1272 Programmed, Daily on / OFF, 910 pm 710 am 1130 pm Present time

Page 96

SETTING THE TIMER

1. How to set the present time

(Example) To set to 9:10 pm.

 

Operation

Indication

 

 

 

1.

Press the SET button three

The time indication alone

 

times.

flashes.

2.

• Press the HH button until

The display will flash for 10 sec.

 

PM 9 is displayed.

and automatically stop flashing

 

• Press the MM button until

except for the “ : ” symbol.

 

10 is displayed.

 

 

 

 

2. How to set the OFF time

(Example) To stop the air conditioner at 11:30 pm.

OFF TIME

Present time

 

 

Operation

Indication

1.Press the SET button twice. The timer indication alone flashes and the previous set- time is only displayed.

2.

• Press the HH button until

The display will change

 

 

PM 11 is displayed.

automatically back to show the

 

• Press the MM button until

present time after about 10 sec.

 

30 is displayed.

 

 

3.

Press the TIMER SELECT

The present time and

are

 

button twice to set OFF time.

displayed.

 

To cancel the setting, press the TIMER SELECT button twice.

3. How to set the ON time

(Example) To start operation at 7:10 am.

 

ON TIME

 

 

Present time

 

 

 

 

 

 

 

 

Operation

 

Indication

 

 

 

 

 

 

 

 

1.

Press the SET button once.

The timer

 

indication alone

 

 

 

flashes and the previous set-

 

 

time is only displayed.

 

 

2.

• Press the HH button until

The display will change

 

 

 

AM 7 is displayed.

automatically back to show the

 

• Press the MM button until

present time after about 10 sec.

 

10 is displayed.

 

 

 

 

 

3.

Press the TIMER SELECT

The present time and

 

are

 

 

button once to set ON time.

displayed.

 

 

 

 

 

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button three times.

4. How to set daily ON/OFF repeat timer

(Example) To start operation at 7:10 am. and stop the air conditioner at 11:30 pm.

Present time

OFF TIME

ON TIME

 

 

Programmed

 

 

 

daily ON / OFF

9:10 pm.

7:10 am.

11:30 pm.

Present time

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

Indication

 

 

 

Set the timer ON/OFF times as

The present time PM 9:10 and

shown in 2 and 3.

 

are displayed.

 

 

 

 

 

 

To cancel the setting, press the TIMER SELECT button once.

NOTE

You can check the timer ON/OFF times after you have set them by pressing the SET button.

5. Backup function

Even if the main power supply to the unit is turned off, the remote controller will store the previous settings in its internal memory for up to 8 hours. If the power is not turned back on within 8 hours, the previous settings will be lost. In this case, the mode settings must be reset by the user.

8

OI-139-8-EG

 

Image 96
Contents 11,900BTU / h 17,500BTU / hSafety Precautions Prohibit Table of Contents STK-RCS-7TWSUA Applicable MULTI-OUTDOOR Units Operating Range Indoor Air Intake Temp Outdoor Air Intake TempSpecifications Unit SpecificationsIndoor Unit XMS0972 & PNR-XS1872 Indoor Unit XMS0972 & PNR-XS1872208V XMS1272 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS1872 XS1872 & PNR-XS1872 Major Component Specifications Indoor UnitIndoor Unit Body XMS0972 Indoor Unit PanelIndoor Unit Body XMS1272 Indoor Unit Body XS1872 Other Component Specifications ModelKTEC-35-S98Indoor heat exchanger sensor ModelPT2M-51H-S3Dimensional Data 534Refrigerant Flow Diagram Refrigerant Flow DiagramIndoor Unit XS1872 & PNR-XS1872 Indoor unit Electrical Data 5250-469008FA2 Maintenance Disassembly ProcedureDisconnect the connectors in the control box Remove the air intake grillRemove the ceiling panel Remove the indoor air temperature sensor Remove the power box and control boxScrew Ground cable CN07 ScrewCN03 CN09 CN06 Remove the main body lower section Remove the drain pump and float switch Remove the heat exchanger sensorRemove the turbo fan and fan motor Remove the heat exchangerFunctions Operation FunctionsEmergency operation PAM- controlTimer backup Lamp colorsProtective Functions Freeze preventionTroubleshooting Precautions before Performing Inspection or RepairMethod of Self-Diagnostics Self-diagnostics Lamps Using the TEST/T-RUN terminals Checking the Indoor and Outdoor UnitsReplace the controller Replace the circuit board or the fuseSerial Communication Error Identification Procedure Before the OperationOff Blinking Illuminated Condition E01Terminal board Outdoor Unit Condition E12 Trouble Diagnosis of Fan Motor Indoor Fan MotorNoise Malfunction and Electromagnetic Interference Noise malfunctionElectromagnetic interference Locations most susceptible to noise Trouble CorrectionXMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 Mode D’EMPLOI Pub. OI-85264181141000 SanyoFeatures ContentsAlert Symbols Installation LocationSafety Instructions Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit HR. Timer button 1-HOUR OFF Timer Temperature setting buttons TempMode selector button SensorUsing the Remote Control Unit Operation with the Remote Control Unit Automatic fan speedManual fan speed Setting the Timer Cooling and DRY ModeSpecial Remarks How it works?Operation Indication 1030 pm 710 am 1100 am Present timeUsing the 1-HOUR OFF Timer Adjusting the Airflow DirectionTips for Energy Saving Do notCare and Cleaning When the air conditioner is not runningCleaning the flaps Cleaning the main unit and remote control unitHow to remove the filter How to remove the air intake grilleAir filter Care After a prolonged idle periodTroubleshooting Wired Remote ControllerOperating Range XS1872 & PNR-XS1872 XS1271 XS1872 Pub. OI-85264181108001 SanyoOI-108-2-EG Important Multiple use is applied for the model XS1872 only OI-108-4-EG OI-108-5-EG OI-108-6-EG OI-108-7-EG OI-108-8-EG OI-108-9-EG OI-108-10-EG OI-108-11-EG OI-108-12-EG OI-108-13-EG OI-108-14-EG OI-108-15-EG Appendix C Installation Instructions Contents For Indoor UnitFor safe installation and trouble-free operation, you must Please Read Before Starting…In a Ceiling or Wall …In a RoomTools Required for Installation not supplied Accessories Supplied with Unit TableGeneral Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationEmbedding the Tubing and Wiring H1, H2, H3, H4How to Install the Indoor Unit Preparation for SuspendingSuspending the Indoor Unit Placing the Unit Inside the CeilingInstalling the Drain Piping Do not install an air bleeder asAttach so that the hose band Fastener is on the sideChecking the Drainage 10aInstalling the Ceiling Panel Indoor unit Gaps Ceiling surface Ceiling panelWiring the Ceiling Panel and the Indicator Attaching the air-intake grilleChecking After Installation When Removing the Ceiling Panel for ServicingAdjusting the Auto Flap Wiring Instructions General precautions on wiringHow to connect wiring to the terminal For Indoor Unit For Outdoor Unit For solid core wiring or F-cableFor stranded wiring How to Test Run the Air Conditioner Remote Control Unit Installation Position Rear side Remote control unit mountTo take out the remote control unit, pull it forward Mounting on a WallAddress Switch Address Setting of the Remote Control UnitConnecting a Home Automation Device Installation Check SheetSTK-RCS-7TWSUA STK-RCS-7TWSUA Pub. OI-85264181139000 SanyoDo not cool or heat the room too much Hot Start Heating System Timer and Present Time setting buttons SET buttonTimer Select button AutoAutomatic Operation Only for COOL/DRY/HEAT Model Remote Control Unit Display Heating Mode Only for COOL/DRY/HEAT ModelProgrammed Daily on / OFF910 pm 710 am 1130 pm Present time Sweep Cool Drysweep Heat FAN Appendix E Installation Instructions STK-RCS-7TWSUA Parts supplied with the remote controller Remote controller installation guidelinesHow to install the remote controller Installation locationInstalling with in-wall junction box Installing directly onto the wallHow to wire the remote controller ON/OFF

XMS1272, XMS0972 specifications

The Sanyo XMS0972 and XMS1272 are remarkable air conditioning units that blend efficiency with cutting-edge technology. Designed for residential and commercial spaces, these models promise comfort while optimizing energy consumption.

One of the standout features of both the XMS0972 and XMS1272 is their advanced inverter technology. This feature allows the units to adjust their cooling capacity based on the room's ambient temperature. As a result, the air conditioners can maintain a consistent temperature without the frequent on/off cycles associated with traditional units. This not only ensures a more stable climate but also significantly reduces energy consumption, making them eco-friendly options.

Another significant characteristic is the Quiet Operation mode. Both models are engineered with noise reduction technology, providing a tranquil environment for users. This is particularly beneficial for bedrooms, offices, or libraries where noise levels can be a concern. The XMS models operate at a whisper-quiet level, allowing users to focus on their tasks or enjoy a peaceful night's sleep without disruption.

The Sanyo XMS0972 and XMS1272 also feature a user-friendly digital interface. With an intuitive remote control and an easy-to-read display, setting your desired temperature or switching modes has never been easier. Moreover, the smart diagnostic capability allows for quick troubleshooting, helping to identify any issues to ensure peak performance throughout their lifespan.

Both models are equipped with a 24-hour timer, adding convenience for users who wish to come home to a pre-cooled or heated environment. This feature enhances comfort and saves energy when the unit is not in use.

In terms of design, the Sanyo XMS units boast a sleek and modern aesthetic that seamlessly integrates into various interior styles. Their compact size allows for flexible installation options, making them suitable for various living and working spaces.

The XMS line also emphasizes air purification, incorporating advanced filters that capture dust, allergens, and other pollutants. This results in not just temperature control but also improved air quality, contributing to a healthier living environment.

In conclusion, the Sanyo XMS0972 and XMS1272 air conditioning units stand out for their energy efficiency, quiet operation, user-friendly features, and air purification capabilities. These characteristics make them an ideal choice for individuals and businesses looking for reliable and sophisticated climate control solutions.