Sanyo XMS0972 Product Information, Important Multiple use is applied for the model XS1872 only

Page 58

PRODUCT INFORMATION

If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.

Model No. __________________________________

Serial No. ___________________________________

Date of purchase _____________________________

Dealer’s address _____________________________

Phone number ________________

ALERT SYMBOLS

The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or unsafe CAUTION practice which can result in personal

injury or product or property damage.

INSTALLATION LOCATION

We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.

Do not install this air conditioner

where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.

Do not install the air conditioner where excessively high heat-generating objects are placed.

Avoid:

To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

ELECTRICAL REQUIREMENTS

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

SAFETY INSTRUCTIONS

Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.

This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

 

 

Never use or store gasoline or other

 

 

 

flammable vapor or liquid near the air

 

 

 

conditioner — it is very dangerous.

 

 

• This air conditioner has no ventilator

 

 

 

for intaking fresh air from outdoors.

 

 

 

You must open doors or windows

 

 

 

frequently when you use gas or oil

 

 

 

heating appliances in the same room,

 

 

 

which consume a lot of oxygen from

 

 

 

the air. Otherwise there is a risk of

 

 

 

suffocation in an extreme case.

 

 

 

 

 

 

 

 

 

 

Do not turn the air conditioner on and

CAUTION

 

 

 

off from the power mains switch. Use

 

 

 

 

 

 

the ON/OFF operation button.

 

 

• Do not stick anything into the air outlet

 

 

 

of the outdoor unit. This is dangerous

 

 

 

because the fan is rotating at high

 

 

 

speed.

 

 

Do not let children play with the air

 

 

 

conditioner.

 

 

Do not cool the room too much if

 

 

 

babies or invalids are present.

 

 

 

 

IMPORTANT “Multiple use” is applied for the model XS1872 only.

“Single use” means that only one indoor unit is con- nected with one outdoor unit in a one-unit-to-one-unit configuration.

“Multiple use” (i.e. Flexi-Multi system) means that two or more indoor units are connected with one outdoor unit in a multiple-unit-to-one-unit configuration.

OI-108-3-EG

3

 

Image 58
Contents 11,900BTU / h 17,500BTU / hSafety Precautions Prohibit Table of Contents STK-RCS-7TWSUA Applicable MULTI-OUTDOOR Units Operating Range Indoor Air Intake Temp Outdoor Air Intake TempUnit Specifications SpecificationsIndoor Unit XMS0972 & PNR-XS1872 XMS0972 & PNR-XS1872 Indoor Unit208V XMS1272 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS1872 XS1872 & PNR-XS1872 Indoor Unit Body XMS0972 Major Component SpecificationsIndoor Unit Indoor Unit PanelIndoor Unit Body XMS1272 Indoor Unit Body XS1872 Indoor heat exchanger sensor Other Component SpecificationsModelKTEC-35-S98 ModelPT2M-51H-S3Dimensional Data 534Refrigerant Flow Diagram Refrigerant Flow DiagramIndoor Unit XS1872 & PNR-XS1872 Indoor unit 5250-46900 Electrical Data8FA2 Disconnect the connectors in the control box MaintenanceDisassembly Procedure Remove the air intake grillRemove the ceiling panel Remove the indoor air temperature sensor Remove the power box and control boxScrew Ground cable CN07 ScrewCN03 CN09 CN06 Remove the main body lower section Remove the drain pump and float switch Remove the heat exchanger sensorRemove the turbo fan and fan motor Remove the heat exchangerEmergency operation FunctionsOperation Functions PAM- controlTimer backup Lamp colorsProtective Functions Freeze preventionPrecautions before Performing Inspection or Repair TroubleshootingMethod of Self-Diagnostics Self-diagnostics Lamps Replace the controller Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the circuit board or the fuseOff Blinking Illuminated Serial Communication Error Identification ProcedureBefore the Operation Condition E01Terminal board Outdoor Unit Condition E12 Trouble Diagnosis of Fan Motor Indoor Fan MotorElectromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Locations most susceptible to noise Trouble CorrectionXMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 Mode D’EMPLOI Pub. OI-85264181141000 SanyoFeatures ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Mode selector button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp SensorUsing the Remote Control Unit Automatic fan speed Operation with the Remote Control UnitManual fan speed Special Remarks Setting the TimerCooling and DRY Mode How it works?Operation Indication 1030 pm 710 am 1100 am Present timeTips for Energy Saving Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Do notCleaning the flaps Care and CleaningWhen the air conditioner is not running Cleaning the main unit and remote control unitAir filter How to remove the filterHow to remove the air intake grille Care After a prolonged idle periodWired Remote Controller TroubleshootingOperating Range XS1872 & PNR-XS1872 XS1271 XS1872 Pub. OI-85264181108001 SanyoOI-108-2-EG Important Multiple use is applied for the model XS1872 only OI-108-4-EG OI-108-5-EG OI-108-6-EG OI-108-7-EG OI-108-8-EG OI-108-9-EG OI-108-10-EG OI-108-11-EG OI-108-12-EG OI-108-13-EG OI-108-14-EG OI-108-15-EG Appendix C Installation Instructions Contents For Indoor Unit…In a Ceiling or Wall For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a RoomGeneral Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationEmbedding the Tubing and Wiring H1, H2, H3, H4Suspending the Indoor Unit How to Install the Indoor UnitPreparation for Suspending Placing the Unit Inside the CeilingAttach so that the hose band Installing the Drain PipingDo not install an air bleeder as Fastener is on the sideChecking the Drainage 10aInstalling the Ceiling Panel Indoor unit Gaps Ceiling surface Ceiling panelWiring the Ceiling Panel and the Indicator Attaching the air-intake grilleAdjusting the Auto Flap Checking After InstallationWhen Removing the Ceiling Panel for Servicing Wiring Instructions General precautions on wiringFor Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring How to Test Run the Air Conditioner To take out the remote control unit, pull it forward Remote Control Unit Installation PositionRear side Remote control unit mount Mounting on a WallAddress Switch Address Setting of the Remote Control UnitConnecting a Home Automation Device Installation Check SheetSTK-RCS-7TWSUA STK-RCS-7TWSUA Pub. OI-85264181139000 SanyoDo not cool or heat the room too much Hot Start Heating System Timer and Present Time setting buttons SET buttonTimer Select button AutoAutomatic Operation Only for COOL/DRY/HEAT Model Remote Control Unit Display Heating Mode Only for COOL/DRY/HEAT ModelDaily on / OFF Programmed910 pm 710 am 1130 pm Present time Sweep Cool Drysweep Heat FAN Appendix E Installation Instructions STK-RCS-7TWSUA How to install the remote controller Parts supplied with the remote controllerRemote controller installation guidelines Installation locationInstalling with in-wall junction box Installing directly onto the wallHow to wire the remote controller ON/OFF