Sensor

A temperature sensor inside the remote control unit senses the room temperature.

ON/OFF operation button

This button is for turning the air conditioner on and off.

1 HR. TIMER button (1-HOUR OFF TIMER)

: When you press this button, regardless of whether the unit is operating or stopping, the unit operates for one hour and then shuts down.

Temperature setting buttons (TEMP.)

Press the

button to increase the set temperature.

Press the

button to reduce the set temperature.

The temperature setting changes by 1 °C or 2 °F each time one of the TEMP. buttons is pressed.

MODE selector button

Use this button to select DRY, COOL or FAN mode.

(DRY)

: The air conditioner reduces the humidity in the room.

(COOL) : The air conditioner makes the room cooler.

(FAN)

: The air conditioner works only as a circulation fan.

NIGHT SETBACK button

For details, see “4. Night Setback Mode”. When you press this button in the DRY or COOL mode, the mark appears in the display, and the remote control unit will automatically adjust the set temperature to save energy.

CLOCK button

Time display selector button

This switches the time display between 24-hour time and 12-hour time.

ACL button (ALL CLEAR)

Puts the remote control unit into pre-operation status. Always press this button after replacing the batteries.

NOTE

(Cover closed)

The illustration above pictures the remote control unit after the cover has been opened.

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow.

OI-108-7-EG

7

 

Image 62
Contents 11,900BTU / h 17,500BTU / hSafety Precautions Prohibit Table of Contents STK-RCS-7TWSUA Applicable MULTI-OUTDOOR Units Operating Range Indoor Air Intake Temp Outdoor Air Intake TempIndoor Unit XMS0972 & PNR-XS1872 SpecificationsUnit Specifications 208V Indoor UnitXMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 XMS1272 & PNR-XS1872 XS1872 & PNR-XS1872 XS1872 & PNR-XS1872 Indoor Unit Body XMS0972 Major Component SpecificationsIndoor Unit Indoor Unit PanelIndoor Unit Body XMS1272 Indoor Unit Body XS1872 Indoor heat exchanger sensor Other Component SpecificationsModelKTEC-35-S98 ModelPT2M-51H-S3Dimensional Data 534Indoor Unit XS1872 & PNR-XS1872 Indoor unit Refrigerant Flow DiagramRefrigerant Flow Diagram 8FA2 Electrical Data5250-46900 Disconnect the connectors in the control box MaintenanceDisassembly Procedure Remove the air intake grillRemove the ceiling panel Remove the indoor air temperature sensor Remove the power box and control boxScrew Ground cable CN07 ScrewCN03 CN09 CN06 Remove the main body lower section Remove the drain pump and float switch Remove the heat exchanger sensorRemove the turbo fan and fan motor Remove the heat exchangerEmergency operation FunctionsOperation Functions PAM- controlTimer backup Lamp colorsProtective Functions Freeze preventionMethod of Self-Diagnostics TroubleshootingPrecautions before Performing Inspection or Repair Self-diagnostics Lamps Replace the controller Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the circuit board or the fuseOff Blinking Illuminated Serial Communication Error Identification ProcedureBefore the Operation Condition E01Terminal board Outdoor Unit Condition E12 Trouble Diagnosis of Fan Motor Indoor Fan MotorElectromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Locations most susceptible to noise Trouble CorrectionXMS0972 & PNR-XS1872 XMS1272 & PNR-XS1872 Mode D’EMPLOI Pub. OI-85264181141000 SanyoFeatures ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Mode selector button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp SensorUsing the Remote Control Unit Manual fan speed Operation with the Remote Control UnitAutomatic fan speed Special Remarks Setting the TimerCooling and DRY Mode How it works?Operation Indication 1030 pm 710 am 1100 am Present timeTips for Energy Saving Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Do notCleaning the flaps Care and CleaningWhen the air conditioner is not running Cleaning the main unit and remote control unitAir filter How to remove the filterHow to remove the air intake grille Care After a prolonged idle periodOperating Range TroubleshootingWired Remote Controller XS1872 & PNR-XS1872 XS1271 XS1872 Pub. OI-85264181108001 SanyoOI-108-2-EG Important Multiple use is applied for the model XS1872 only OI-108-4-EG OI-108-5-EG OI-108-6-EG OI-108-7-EG OI-108-8-EG OI-108-9-EG OI-108-10-EG OI-108-11-EG OI-108-12-EG OI-108-13-EG OI-108-14-EG OI-108-15-EG Appendix C Installation Instructions Contents For Indoor Unit…In a Ceiling or Wall For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a RoomGeneral Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationEmbedding the Tubing and Wiring H1, H2, H3, H4Suspending the Indoor Unit How to Install the Indoor UnitPreparation for Suspending Placing the Unit Inside the CeilingAttach so that the hose band Installing the Drain PipingDo not install an air bleeder as Fastener is on the sideChecking the Drainage 10aInstalling the Ceiling Panel Indoor unit Gaps Ceiling surface Ceiling panelWiring the Ceiling Panel and the Indicator Attaching the air-intake grilleAdjusting the Auto Flap Checking After InstallationWhen Removing the Ceiling Panel for Servicing Wiring Instructions General precautions on wiringFor stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit For solid core wiring or F-cable How to Test Run the Air Conditioner To take out the remote control unit, pull it forward Remote Control Unit Installation PositionRear side Remote control unit mount Mounting on a WallAddress Switch Address Setting of the Remote Control UnitConnecting a Home Automation Device Installation Check SheetSTK-RCS-7TWSUA STK-RCS-7TWSUA Pub. OI-85264181139000 SanyoDo not cool or heat the room too much Hot Start Heating System Timer and Present Time setting buttons SET buttonTimer Select button AutoAutomatic Operation Only for COOL/DRY/HEAT Model Remote Control Unit Display Heating Mode Only for COOL/DRY/HEAT Model910 pm 710 am 1130 pm Present time ProgrammedDaily on / OFF Sweep Cool Drysweep Heat FAN Appendix E Installation Instructions STK-RCS-7TWSUA How to install the remote controller Parts supplied with the remote controllerRemote controller installation guidelines Installation locationInstalling with in-wall junction box Installing directly onto the wallHow to wire the remote controller ON/OFF