Schumacher INC-812A, 94080037, 00-99-000886/1208 operating instructions General Charging Notes

Page 11

11.5DESULFATION MODE: If a battery is left discharged for an extended period of time, it could become sulfated and not accept a normal charge. The CHARGING LED will blink when the special desulfation mode is ac- tivated. When blinking, the charger has switched to the Desulfation Mode of operation. If successful, normal charging will resume after the battery is desulfated. The CHARGING LED will then stop blinking and light continu- ously. Desulfation could take up to 10 hours. If desulfation fails, charging will abort and the CONNECTED LED will remain lit and the display will read BAD BAT.

11.6COMPLETION OF CHARGING: Charge completion is indicated by the CHARGED LED. When lit, the charger has stopped charging and has switched to Maintain Mode of operation.

11.7MAINTAIN MODE: When the CHARGED LED is lit, the charger has started Maintain Mode. This mode of operation is known as Float-Mode Monitoring. In this mode, the charger keeps the battery fully charged by delivering a small current, when necessary. The voltage is maintained at a level determined by the BATTERY TYPE selected. To finish the charging cycle press the START/STOP button, and the OFF LED will light.

11.8GENERAL CHARGING NOTES:

The fan runs whenever one or more batteries are being charged.

If the charge mode is changed after charging has started (by pressing the BATTERY TYPE button), the charging process stops.

The voltage displayed during charging, is the charging voltage and usually will be higher than the battery’s resting voltage.

12.using the volt meter to test battery state of charge

12.1OVERVIEW

The charger has a built in volt meter to test your battery’s state of charge. The charger does not have a built in load tester. As such, a recently charged battery could have a temporarily high voltage due to what is known as “surface charge”. The voltage of such a battery will eventually drop during the period immediately after the charging system is disen- gaged. Consequently, the tester could display inconsistent values for such a battery. For a more accurate reading, the surface charge should be removed by temporarily creating a load on the battery by turning on the lights or other accessories.

The battery tester is only designed to test 12V batteries. Testing a device with a rapidly changing voltage could yield unexpected or inaccurate results.

12.2TESTING SEQUENCE: There are three basic steps required to test the battery state of charge:

1.Connect the battery charger’s clips to the battery. Be sure to follow all of the precautions listed under sections 6 and 7.

8

Image 11
Contents Read Entire Manual Before Using this Product Page Table of Contents Important Safety Instructions Preparing to Charge Charger Location DC Connection PrecautionsBattery charging ac connections Grounding Methods Assembly instructionsDigital Display Button Battery Type ButtonControl panel Overview Operating instructionsGeneral Charging Notes Using the volt meter to test battery state of chargeDuration of the charging process depends on three factors Battery percent and charge timeStorage instructions Maintenance instructionsProblem Possible Cause Solution TroubleshootingLimited warranty Page LEA Todo EL Manual Antes DE Usar Este Producto Precaucion Page Table of Contents Instrucciones DE Seguridad Importantes PREPARación de la carga Precauciones PersonalesPrecauciones DE LA Conexión CC Ubicación DEL CargadorSiga Estos Pasos cuando la batería esté afuera del vehículo Bateria Cargando Conexiones AC Panel DE Control 10.2 Botón de Battery TypeMétodos a tierra Instrucciones DE EnsamblajePage Instrucciones DE Funcionamiento Aspectos Generales Notas Generales Relacionadas CON LA Carga La duración del proceso de carga depende de tres factores Porcentaje DE Batería Y Tiempo DE CargaInstrucciones DE Almacenaje Localización Y Solución DE ProblemasInstrucciones DE Mantenimiento Figuraciones