Sanyo KS1271 Using the Remote Control Unit, ACL button ALL Clear, How to Install Batteries

Page 10

Remote Control Unit (continued)

SENSOR button

When you press this button (use a small-tipped object such as a ballpoint pen),

 

 

 

the

mark will appear at the display. And the room temperature is detected by

 

 

 

the sensor which is built into the indoor unit and the air conditioner is controlled

 

 

 

accordingly.

 

 

 

If the remote control is located near a heat source, such as a space heater or in direct

 

NOTE

 

 

 

 

sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

 

 

 

 

 

 

 

Temperature Display Selector button

This switches the temperature display between °C and °F.

 

 

 

 

Time Display Selector button

This switches the time display between 24-hour time and 12-hour time.

 

 

 

 

ACL button (ALL CLEAR)

Puts the remote control unit into pre-operation status. Always press this button

 

 

 

after replacing the batteries.

 

 

 

 

ADDRESS switch

• The address switch changes to prevent mixing of signals from remote control

 

 

 

 

units when two air conditioners are installed next to each other. Normally, the

 

 

 

 

address switch is set to A. For more information, please contact the dealer

 

 

 

 

where you made the purchase.

 

 

 

• Normally, the tabs on the remote control unit should not be bent.

 

 

 

 

 

NOTE

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

Using the Remote Control Unit

How to Install Batteries

1. Slide the cover in the direction indicated by the arrow and remove it.

2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment.

3. Use a thin object such as the tip of a pen to press the ACL button.

ACL button

NOTE

The batteries last about six months, depending on how much you use the remote control unit. Replace the batteries when the remote control unit’s display fails to light, or when the remote control cannot be used to change the air conditioner’s settings.

Use two fresh leak-proof type-AAA alkaline batteries.

In replacing batteries, follow the instructions as mentioned in the sub- section “How to Install Batteries”.

If you do not use the remote control unit more than 1 month, take out the batteries.

10

OI-803-10-EG

 

Image 10
Contents Mode D’EMPLOI This air conditioner uses the new refrigerant R410AFeatures Alert Symbols ContentsProduct Information Safety Instructions Installation LocationElectrical Requirements Indoor Unit Names of PartsOutdoor Unit Unit Display and Operation Button Quiet lampRemote Control Unit Display Hour OFF Timer Remote Control UnitOn Time Cool DRYFAN How to Install Batteries Using the Remote Control UnitACL button ALL Clear Using the Remote Control Unit Operation Operation with the Remote Control UnitStep Fan Only Operation with the Remote Control UnitAdjusting the Fan Speed Press the ON/OFF operation buttonCooling and DRY Mode Night Setback ModeNight Setback Mode is used for saving energy High Power Mode Quiet ModeION Mode ‘‘DRY’’ Operation Remote Control UnitSpecial Remarks Cooling OperationHow to set the present time Setting the TimerOperation Indication To cancel a timer program Press the Cancel button Setting the TimerRepeat timer 1030 pm 710 am 1100 am Present timeCancellation procedure Using the 1-Hour OFF TimerSetting procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction Cool Sweep DRY FANOperation without the Remote Care and CleaningWhen the air conditioner is not running Control UnitCare and Cleaning Filter How to clean the air clean filterWashing the grille with water Air clean filter Negative ion generator metal electrodes inside plastic caseOperating Range TroubleshootingTrouble Possible Cause Remedy Page Caractéristiques Symboles d’avertissement Informations sur le produitInstructions relatives à l’alimentation Emplacement d’installationConseils de sécurité Élément Extérieur Nom des piècesÉlément Intérieur RemarqueAfficheur de l’appareil et bouton de fonctionnement TimerOperation Télécommande Affichage Télécommande Télécommande suite On TIME/OFF TimeUtilisation de la télécommande Pour retirer la télécommande, tirer vers l’avant Utilisation de la télécommande suiteClimatiseur élément intérieur Récepteur Télécommande TrouÉtape Remarque Fonctionnement avec télécommandeFonctionnement ÉtapeVentilateur uniquement Fonctionnement avec télécommande suiteRéglage de la vitesse du ventilateur Vitesse automatiqueEn mode de refroidissement et séchage et Mode économie nocturneCe mode permet de réduire la consommation d’énergie Mode de fonctionnement Haute puissance Mode de silencieux QuietMode d’ionisation ION Fonctionnement séchage TélécommandeRemarques spéciales RefroidissementRéglage du moment de mise à l’arrêt OFF Réglage du temporisateurDémarche Affichage 1030 p.m 710 a.m 1100 a.m Réglage du temporisateur suiteRéglage du moment de mise en marche on ProgrammationConseils pour économiser l’énergie HR. TimerEmploi du temporisateur 1 heure Daily ON/OFF RepeatRéglage du flux d’air Sweep Cool DRY FANElément Intérieur Fonctionnement sans télécommandeEntretien et nettoyage Si le climatiseur ne fonctionne pasEntretien et nettoyage suite FrontNettoyage de l’appareil principale et de la télécommande Nettoyage de la grille à l’eauPlage de températures de fonctionnement Guide de dépannagePanne Cause possible Remède Page Sanyo Fisher Company