Remote Control Unit (continued)

Temperature setting buttons Press the button to increase the set temperature.

(TEMP.) Press the button to reduce the set temperature.

The temperature setting changes by 1 °C or 2 °F each time one of the TEMP. buttons is pressed.

QUIET button

: When you press this button, the fan rotates slower than the fan speed

 

setting to provide a quieter operating sound.

 

MODE selector button Use this button to select DRY, COOL or FAN mode.

(DRY)

: The air conditioner reduces the humidity in the room.

(COOL)

: The air conditioner makes the room cooler.

(FAN)

: The air conditioner works only as a circulation fan.

 

 

FAN SPEED selector button

: The air conditioner automatically decides the fan speeds.

 

: High fan speed

 

: Medium fan speed

 

: Low fan speed

NIGHT SETBACK button For details, see “4. Night Setback Mode”. When you press this button in the DRY or COOL mode, the mark appears in the display, and the remote control unit will automatically adjust the set temperature to save energy.

FLAP button Press this button either to select the setting of the airflow direction to the auto.

 

 

flap in each mode or one of the six possible positions manually or to select the

 

 

sweep function which moves the flap up and down automatically.

 

 

: Auto flap setting: If selected in a cooling or dry operation, the flap is set at

 

 

position (7) in the following chart.

 

 

: The airflow direction can be set manually. (six positions)

 

 

: The flap moves up and down automatically.

 

 

When you press the FLAP button, the air flow direction will be changed one by

 

NOTE

 

 

one as follows.

 

 

 

 

SWEEP

 

 

 

HIGH POWER button

: If this button is pressed during DRY, COOL or FAN operation, the unit

 

 

operates at maximum output for 30 minutes, regardless of the desired

 

 

temperature.

 

 

The fan speed is 1 step above “High”.

 

 

 

ON TIME/OFF TIME setting No display: The timer does not operate.

buttons

: The air conditioner starts at the set time.

 

 

: The air conditioner stops at the set time.

 

 

: The air conditioner stops and starts, or starts and stops, at the

 

 

set times every day. For details, see “Setting the Timer”.

OI-803-9-EG

9

 

Image 9
Contents This air conditioner uses the new refrigerant R410A Mode D’EMPLOIFeatures Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit Quiet lamp Unit Display and Operation ButtonRemote Control Unit Display Remote Control Unit Hour OFF TimerOn Time DRY CoolFAN Using the Remote Control Unit How to Install BatteriesACL button ALL Clear Using the Remote Control Unit Operation with the Remote Control Unit OperationStep Adjusting the Fan Speed Operation with the Remote Control UnitFan Only Press the ON/OFF operation buttonNight Setback Mode Cooling and DRY ModeNight Setback Mode is used for saving energy Quiet Mode High Power ModeION Mode Special Remarks Remote Control Unit‘‘DRY’’ Operation Cooling OperationSetting the Timer How to set the present timeOperation Indication Repeat timer Setting the TimerTo cancel a timer program Press the Cancel button 1030 pm 710 am 1100 am Present timeSetting procedure Using the 1-Hour OFF TimerCancellation procedure Operation together with the Daily ON/OFF Repeat TimerCool Sweep DRY FAN Adjusting the Airflow DirectionWhen the air conditioner is not running Care and CleaningOperation without the Remote Control UnitCare and Cleaning Washing the grille with water Air clean filter How to clean the air clean filterFilter Negative ion generator metal electrodes inside plastic caseTroubleshooting Operating RangeTrouble Possible Cause Remedy Page Caractéristiques Informations sur le produit Symboles d’avertissementEmplacement d’installation Instructions relatives à l’alimentationConseils de sécurité Élément Intérieur Nom des piècesÉlément Extérieur RemarqueTimer Afficheur de l’appareil et bouton de fonctionnementOperation Télécommande Affichage Télécommande On TIME/OFF Time Télécommande suiteUtilisation de la télécommande Climatiseur élément intérieur Récepteur Télécommande Utilisation de la télécommande suitePour retirer la télécommande, tirer vers l’avant TrouFonctionnement Fonctionnement avec télécommandeÉtape Remarque ÉtapeRéglage de la vitesse du ventilateur Fonctionnement avec télécommande suiteVentilateur uniquement Vitesse automatiqueMode économie nocturne En mode de refroidissement et séchage etCe mode permet de réduire la consommation d’énergie Mode de silencieux Quiet Mode de fonctionnement Haute puissanceMode d’ionisation ION Remarques spéciales TélécommandeFonctionnement séchage RefroidissementRéglage du temporisateur Réglage du moment de mise à l’arrêt OFFDémarche Affichage Réglage du moment de mise en marche on Réglage du temporisateur suite1030 p.m 710 a.m 1100 a.m ProgrammationEmploi du temporisateur 1 heure HR. TimerConseils pour économiser l’énergie Daily ON/OFF RepeatSweep Cool DRY FAN Réglage du flux d’airEntretien et nettoyage Fonctionnement sans télécommandeElément Intérieur Si le climatiseur ne fonctionne pasFront Entretien et nettoyage suiteNettoyage de la grille à l’eau Nettoyage de l’appareil principale et de la télécommandeGuide de dépannage Plage de températures de fonctionnementPanne Cause possible Remède Page Sanyo Fisher Company