How to Use the Remote When using the remote control unit, always point the unit’s transmitter head Control Unit directly at the air conditioner’s receiver.

Air conditioner (Indoor unit)

 

Receiver

Remote control

(Transmitter head)

unit

 

Remote Control Unit The remote control unit may be operated either from a non-fixed position or from Installation Position a wall-mounted position. To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places:

DO NOT • In direct sunlight

Behind a curtain or other places where it is covered

More than 26 feet (8 m) away from the air conditioner

In the path of the air conditioner’s airstream

Where it may become extremely hot or cold

Where it may be subject to electrical or magnetic noise

Where there is an obstacle between the remote control unit and air conditioner (since a check signal is sent from the remote control unit every 5 minutes)

Mounting the Remote Control Before mounting the remote control unit, press the ON/OFF operation button at Unit the mounting location to make sure that the air conditioner operates from that

location. The indoor unit should make a beeping sound to indicate that it has received the signal.

Remote control

Rear side

 

unit mount

 

Press

Mounting screws 5/32 x 5/8" (4 x 16 mm)

(included)

Set in place

Hole

To prevent loss of the remote control unit, you can connect the remote control unit to the mount by passing a string through the remote control unit and attachment hole.

 

To take out the remote control unit, pull it forward.

When Holding the Remote

• When using the remote control unit and during air conditioner operation, the

Control Unit

transmitter on the remote control unit should be pointed toward the receiver on

 

the indoor unit.

 

• Make sure that there are no objects between the remote control unit and

 

receiver which could block the signal.

OI-807-11-EG

11

 

Image 51
Contents 17,500BTU / h KMS1872 Capacity Indoor Model No Product Code No 500BTU / h KMS0772000BTU / h KMS0972 11,900BTU / h KMS1272Please Read Before Starting Table of Contents Applicable MULTI-OUTDOOR Units Indoor Air Intake Temp Outdoor Air Intake Temp Temperature Indoor Air Intake Temp Outdoor Air Intake TempKMS0772 Unit Specifications208V KMS0972 KMS0972 KMS1272 KMS1272 KMS1872 KMS1872 KMS2472 KMS2472 Indoor Unit Major Component SpecificationsCB-KMS0972 CB-KMS1272 CB-KMS1872 CB-KMS2472 Other Component Specifications Temperature F CResistance k ohm KMS0972 KMS1272 Dimensional DataIndoor Unit KMS1872 KMS2472 Indoor Unit KMS0772 KMS0972 KMS1272 Indoor unit Refrigerant Flow DiagramPerformance Data Air Throw Distance ChartsIndoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit KMS0772 KMS0972 KMS1272 Electric Wiring Diagrams8FA2-5257-70500-0 Operation Functions Emergency operationPAM- control Lamp colors Timer backupFreeze prevention Protective FunctionsMethod of Self-Diagnostics Precautions before Performing Inspection or RepairBlinking On Illuminated Self-diagnostics LampsCode Diagnostics item Indication on indoor unitReplace the circuit board or the fuse Replace the controllerChecking the serial communications Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Checking the indoor unit Control Check items unit operationIndoor Fan Motor Trouble Diagnosis of Fan MotorLocations most susceptible to noise Trouble Correction Noise Malfunction and Electromagnetic InterferenceNoise malfunction Electromagnetic interferenceKMS0772 KMS0972 KMS1272 KMS1872 KMS2472 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Quiet lamp Unit Display and Operation ButtonRemote Control Unit Display Transmitter Remote Control UnitHR. Timer button Advance buttonDRY ACL button ALL Clear Using the Remote Control UnitHow to Install Batteries Temperature Display Selector buttonUsing the Remote Control Unit Operation Operation with the Remote Control UnitPress the ON/OFF operation button Operation with the Remote Control UnitNight Setback Mode is used for saving energy Cooling and DRY ModeQuiet Mode Power failure during operation Special RemarksClicking sound is heard from the air conditioner Operation Indication Setting the TimerSetting the Timer To cancel a timer program Press the Cancel button1030 pm 710 am 1100 am Present time Operation together with the Daily ON/OFF Repeat Timer Using the 1-Hour OFF TimerSetting procedure Cancellation procedureSweep function Adjusting the Airflow DirectionSetting the airflow manually HorizontalControl Unit Care and CleaningWhen the air conditioner is not running Operation without the RemoteAir intake grille Care and CleaningHow to remove the anti-mold filter How to replace the anti-mold filterWashing the grille with water How to clean the air clean filterHow to install the air clean filter Cleaning the negative ion generatorTroubleshooting Operating RangeTrouble Possible Cause Remedy Appendix B Installation Instructions For Indoor Unit Contents…In a Room For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a Ceiling or WallGeneral Additional Materials Required for Installation Installation Site Selection150 L1+L2+L3+L4 230 Embedding the Tubing and WiringHow to Install the Indoor Unit Remove the Rear Panel from the UnitMake a Hole Install the Rear Panel on the Wall If Wooden WallIf Block, Brick, Concrete or Similar Type Wall Cut by the sharp aluminum fins How to remove the grilleHow to replace the grille Be sure to wear work glovesIndoor unit types KMS1872, KMS2472 Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringWiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable Loose wiring may causeFore, be sure all wiring is How to connect wiring to the terminal For Indoor UnitRight-side tubing MountingSwitching drain hose and drain cap Left-side tubingDrain cap Risk of Electric Shock To unmount indoor unitOperation lamp Timer lamp Quiet lamp ION lamp How to Test Run the Air ConditionerMounting on a Wall Remote Control Unit Installation PositionAddress Setting of the Remote Control Unit Address SwitchInstallation Check Sheet Connecting a Home Automation device