Sanyo KMS1872, KMS2472 How to clean the air clean filter, Washing the grille with water

Page 63

Air Clean Filter

How to install the air clean filter

How to clean the air clean filter

NOTE

Care and Cleaning (continued)

The air clean filter removes dust and dirt from the air, and reduces odors and smoke from tobacco.

This air clean filter cannot remove harmful gases or vapors nor ventilate air in the room. You must open doors or windows frequently when you use gas or oil heating appliances. Otherwise there is a risk of suffocation in extreme cases.

The air clean filter needs to be installed behind the air intake grille.

1.Remove the air intake grille.

2.Install the air clean filter in the position shown in the figure.

3. Remount the air intake grille.

Air clean filter

In general, the filter should be sucked to remove dust in low fan speed of a vacuum cleaner once every three months.

If there is heavily grime on the filter, soak the filter in lukewarm water with neutral detergent diluted 1:500 for 1 to 2 minutes then wash it.

Rinse the filter in clean water, then let it dry on the towel in room temperature.

Do not bend nor give excessive force onto the air clean filter.

If the filter surface is heavily blocked with dirt or damaged, replace it with new one. Purchase a replacement filter at your local dealer. (model STK-FDXB)

Cleaning the main unit and remote control unit

Removing and remounting the air intake grille

CAUTION

Washing the grille with water

Wipe clean using a soft, dry cloth.

To remove stubborn dirt, moisten a cloth in warm water no hotter than 104 °F, wring thoroughly, and then wipe.

The air intake grille can be removed in order to wash it with water.

Refer to “How to remove the anti-mold filter” and “How to replace the anti-mold filter” on page 22.

When using a footstool or the like, be careful not to let it tip over.

Clean the grille gently using a soft sponge, or the like. Then wipe away any remaining moisture.

Neutral detergent may be used to remove stubborn dirt. Then rinse thoroughly with water and wipe away any remaining moisture.

Cleaning the negative ion generator

Follow the steps below when the generator has become dirty.

For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.

Remove the dust on the negative ion generator.

Use a toothbrush, etc. to dust off the end.

Use a cotton swab, etc., to clean around the generator inside the plastic case, taking care not to touch the electrodes.

Negative ion generator

(metal electrodes inside plastic case)

NOTE

During use, the negative ion generator and other metal parts may become discolored: this is normal and not indicative of malfunctioning.

If the dirt on and around the negative ion generator is left to build up, a puffing or sputtering sound will eventually be heard. In this case, clean the generator immediately.

Do not apply excessive force while performing maintenance.

OI-807-23-EG

23

 

Image 63
Contents 17,500BTU / h KMS1872 Capacity Indoor Model No Product Code No 500BTU / h KMS0772000BTU / h KMS0972 11,900BTU / h KMS1272Please Read Before Starting Table of Contents Applicable MULTI-OUTDOOR Units Indoor Air Intake Temp Outdoor Air Intake Temp Temperature Indoor Air Intake Temp Outdoor Air Intake TempKMS0772 Unit Specifications208V KMS0972 KMS0972 KMS1272 KMS1272 KMS1872 KMS1872 KMS2472 KMS2472 Indoor Unit Major Component SpecificationsCB-KMS0972 CB-KMS1272 CB-KMS1872 CB-KMS2472 Other Component Specifications Temperature F CResistance k ohm KMS0972 KMS1272 Dimensional DataIndoor Unit KMS1872 KMS2472 Indoor Unit KMS0772 KMS0972 KMS1272 Indoor unit Refrigerant Flow DiagramPerformance Data Air Throw Distance ChartsIndoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit KMS0772 KMS0972 KMS1272 Electric Wiring Diagrams8FA2-5257-70500-0 Operation Functions Emergency operationPAM- control Lamp colors Timer backupFreeze prevention Protective FunctionsMethod of Self-Diagnostics Precautions before Performing Inspection or RepairBlinking On Illuminated Self-diagnostics LampsCode Diagnostics item Indication on indoor unitReplace the circuit board or the fuse Replace the controllerChecking the serial communications Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Checking the indoor unit Control Check items unit operationIndoor Fan Motor Trouble Diagnosis of Fan MotorLocations most susceptible to noise Trouble Correction Noise Malfunction and Electromagnetic InterferenceNoise malfunction Electromagnetic interferenceKMS0772 KMS0972 KMS1272 KMS1872 KMS2472 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Quiet lamp Unit Display and Operation ButtonRemote Control Unit Display Transmitter Remote Control UnitHR. Timer button Advance buttonDRY ACL button ALL Clear Using the Remote Control UnitHow to Install Batteries Temperature Display Selector buttonUsing the Remote Control Unit Operation Operation with the Remote Control UnitPress the ON/OFF operation button Operation with the Remote Control UnitNight Setback Mode is used for saving energy Cooling and DRY ModeQuiet Mode Power failure during operation Special RemarksClicking sound is heard from the air conditioner Operation Indication Setting the TimerSetting the Timer To cancel a timer program Press the Cancel button1030 pm 710 am 1100 am Present time Operation together with the Daily ON/OFF Repeat Timer Using the 1-Hour OFF TimerSetting procedure Cancellation procedureSweep function Adjusting the Airflow DirectionSetting the airflow manually HorizontalControl Unit Care and CleaningWhen the air conditioner is not running Operation without the RemoteAir intake grille Care and CleaningHow to remove the anti-mold filter How to replace the anti-mold filterWashing the grille with water How to clean the air clean filterHow to install the air clean filter Cleaning the negative ion generatorTroubleshooting Operating RangeTrouble Possible Cause Remedy Appendix B Installation Instructions For Indoor Unit Contents…In a Room For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a Ceiling or WallGeneral Additional Materials Required for Installation Installation Site Selection150 L1+L2+L3+L4 230 Embedding the Tubing and WiringHow to Install the Indoor Unit Remove the Rear Panel from the UnitMake a Hole Install the Rear Panel on the Wall If Wooden WallIf Block, Brick, Concrete or Similar Type Wall Cut by the sharp aluminum fins How to remove the grilleHow to replace the grille Be sure to wear work glovesIndoor unit types KMS1872, KMS2472 Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringWiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable Loose wiring may causeFore, be sure all wiring is How to connect wiring to the terminal For Indoor UnitRight-side tubing MountingSwitching drain hose and drain cap Left-side tubingDrain cap Risk of Electric Shock To unmount indoor unitOperation lamp Timer lamp Quiet lamp ION lamp How to Test Run the Air ConditionerMounting on a Wall Remote Control Unit Installation PositionAddress Setting of the Remote Control Unit Address SwitchInstallation Check Sheet Connecting a Home Automation device