Powermatic PWBS-14CS operating instructions Trouble, Probable Cause Remedy

Page 31

Troubleshooting – Mechanical and Electrical Problems

Trouble

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Band Saw does not come up to speed.

Probable Cause

Remedy

 

 

No incoming power.

Verify machine is connected to power

source.

 

 

 

Electrical cord damaged.

Replace cord.

 

 

Building circuit breaker trips or fuse

Verify that band saw is on a circuit of

correct size. If circuit size is correct,

blows.

there is probably a loose electrical

 

lead.

 

 

 

If you have access to a voltmeter, you

 

can separate a switch failure from a

 

motor failure by first, verifying

 

incoming voltage at 110 +/-10% [or

Switch or motor failure (how to

220 +/-10%] and second, checking

the voltage between switch and

distinguish).

motor. If incoming voltage is incorrect,

 

you have a power supply problem. If

 

voltage between starter and motor is

 

incorrect, you have a starter problem.

 

If voltage between starter and motor

 

is correct, you have a motor problem.

 

 

 

Clean motor of dust or debris to allow

Motor overheated.

proper air circulation. Allow motor to

 

cool down before restarting.

 

 

 

If electric motor is suspect, you have

 

two options: Have a qualified

Motor failure.

electrician test the motor for function

or remove the motor and take it to a

 

 

qualified electric motor repair shop

 

and have it tested.

 

 

Miswiring of the unit.

Confirm that all electrical connections

are correct.

 

 

 

 

If the start/stop switch is suspect, you

 

have two options: Have a qualified

Switch failure.

electrician test the switch for function,

or purchase a new start/stop switch

 

 

and establish if that was the problem

 

on change-out.

 

 

Extension cord too light or too long.

Replace with adequate size and

length cord.

 

 

 

Low current.

Contact a qualified electrician.

 

 

31

Image 31
Contents Part No. M-1791216 PowermaticWarranty Period Warranty and ServiceTable of Contents Parts List Table and Trunnion Assembly Page Introduction Features and Specifications Grounding Instructions Disconnect the machine from the power sourceVolt Operation Recommended Minimum Gauge AWG of Extension Cords Extension CordsUnpacking Contents of the Shipping ContainerCarton #2 Stand Mounting Band Saw to Stand Installation and AssemblyRefer to Figures 15 Refer to Figures 17 through Installing Drive BeltInstalling Extension Table Installing Trunnion SupportInstalling Main Table Leveling the Extension Table Installing Rear RailRefer to Figures 22 Refer to Figures 29 Installing Front Rail and Rip FenceAligning Fence to Blade Refer to Figures 33 Resaw GuideBlower Nozzle Work LampDust Collection Installing Quick Tension LeverRiser Block Accessory Stand AttachmentsRefer to Figures 39 AdjustmentsAdjusting 90 Table Stop Tilting the TableTable Aligned with Blade Installing BladesBlade Tension Guide Post and Upper Blade Guard Blade TrackingThrust Bearing Upper Bearing GuidesLower Bearing Guides Refer to Figures 47, 48Refer to Figures 51 Miter GaugeOn/Off Switch MaintenanceShape Blade SelectionWidth PitchMaterial SetBlade Breakage Crosscutting General ProcedureOperation RippingBlade Lead ResawingProbable Cause Remedy TroubleTroubleshooting Operating Problems Trouble Trouble Probable Cause Remedy Optional AccessoriesFor Radius Cutting Blade Selection GuideParts List Body Assembly Replacement PartsIndex No. Part No Description Size Qty Serial # 71210381 and higher Index No. Part No Description Size Qty Body Assembly 200MF 125VAC Parts List Closed Stand AssemblyClosed Stand Assembly PWBS14-FA Parts List Fence and Rail AssemblyFence and Rail Assembly Parts List Table and Trunnion Assembly Parts List Miter Gauge Assembly Parts List Blade Tension Lever Electrical Connections for PWBS-14CS