Powermatic PWBS-14CS Installing Quick Tension Lever, Stand Attachments, Dust Collection

Page 19

Installing Quick Tension Lever

Refer to Figure 36.

Install the quick tension lever (M) onto the shaft as shown, and tighten the two set screws using a 3mm hex wrench. The movement of the blade tension lever is explained under “Installing Blades”.

Stand Attachments

Refer to Figure 37.

1.Mount the two miter gauge hooks (HP3-B) to the side of the stand with two M8x16 carriage bolts (HP3-E) and two M8 flanged hex nuts (HP3-F). Position the hooks at an angle, similar to that shown in Figure 38. The miter gauge can be stored in these hooks.

2.Mount the blade hook (HP3-C)with two M4x10 pan head screws (HP3-H)as shown. The blade hook can store a rolled-up spare blade.

3.Mount the two fence hooks (HP3-A)to the opposite side of the stand with two M8x16 carriage bolts (HP3-E)and two M8 flanged hex nuts (HP3-F). The rip fence can be stored in these hooks when not in use.

Dust Collection

Refer to Figure 38.

The use of a dust collection system (not provided) is strongly advised when using the band saw. It will help keep your shop clean, and reduce the risk of health problems due to wood dust inhalation. The dust collector should have sufficient capacity for this size band saw (minimum 350 cubic feet per minute).

Connect a 4” diameter dust collection hose (not provided) to the port at the back of the band saw, and secure tightly with a hose clamp, as shown.

Note: Dryer vent hose is not suitable for dust collection purposes.

Riser Block Accessory

A Riser Block kit (stock no. 1791217, not provided) is available as an accessory. When installed, it increases resaw capacity (workpiece height capacity) to 12 inches. If you have purchased the Riser Block, consult the instruction sheet that accompanies it.

Figure 36

Figure 37

Figure 38

19

Image 19
Contents Part No. M-1791216 PowermaticWarranty Period Warranty and ServiceTable of Contents Parts List Table and Trunnion Assembly Page Introduction Features and Specifications Grounding Instructions Disconnect the machine from the power sourceVolt Operation Recommended Minimum Gauge AWG of Extension Cords Extension CordsUnpacking Contents of the Shipping ContainerCarton #2 Stand Mounting Band Saw to Stand Installation and AssemblyRefer to Figures 15 Refer to Figures 17 through Installing Drive BeltInstalling Extension Table Installing Trunnion SupportInstalling Main Table Leveling the Extension Table Installing Rear RailRefer to Figures 22 Refer to Figures 29 Installing Front Rail and Rip FenceAligning Fence to Blade Refer to Figures 33 Resaw GuideBlower Nozzle Work LampDust Collection Installing Quick Tension LeverRiser Block Accessory Stand AttachmentsRefer to Figures 39 AdjustmentsAdjusting 90 Table Stop Tilting the TableTable Aligned with Blade Installing BladesBlade Tension Guide Post and Upper Blade Guard Blade TrackingThrust Bearing Upper Bearing GuidesLower Bearing Guides Refer to Figures 47, 48Refer to Figures 51 Miter GaugeOn/Off Switch MaintenanceShape Blade SelectionWidth PitchMaterial SetBlade Breakage Crosscutting General ProcedureOperation RippingBlade Lead ResawingProbable Cause Remedy TroubleTroubleshooting Operating Problems Trouble Trouble Probable Cause Remedy Optional AccessoriesFor Radius Cutting Blade Selection GuideParts List Body Assembly Replacement PartsIndex No. Part No Description Size Qty Serial # 71210381 and higher Index No. Part No Description Size Qty Body Assembly 200MF 125VAC Parts List Closed Stand AssemblyClosed Stand Assembly PWBS14-FA Parts List Fence and Rail AssemblyFence and Rail Assembly Parts List Table and Trunnion Assembly Parts List Miter Gauge Assembly Parts List Blade Tension Lever Electrical Connections for PWBS-14CS