Sanyo 85464359981002 installation instructions and -5 show the detailed dimensions

Page 44

Concealed Duct High-Static Pressure Type (D Type)

3-19. Required Minimum Space for Installation and Service

This air conditioner is usually installed above the ceiling

so that the indoor unit and ducts are not visible. Only the

air intake and air outlet ports are visible from below.

The minimum space for installation and service is shown

in Fig. 3-77.

It is recommended that space be provided (23-5/8"

23-5/8") for checking and servicing the electrical system.

Fig. 3-78 and Table 3-5 show the detailed dimensions of

5-1/8

37

38-37/64

Suspension

bolt pitch

Min. 23-5/8

19-11/16 (Space for service)

11-27/64

Suspension

bolt pitch

Air suction side

Refrigerant tubing

the indoor unit.

 

Electrical

 

Inspection access

component

Min. 23-5/8

(23-5/8" × 23-5/8")

box

Space for

 

 

service

D

Drain pan

Ceiling face

Min. 22-53/64

Min. 5-1/8

Unit: in.

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3-77

 

 

 

 

 

 

 

 

 

 

 

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31-7/32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 3-15/16 = 27-9/16

 

 

 

 

 

 

 

 

 

 

 

 

 

22 - ø1/8

2-5/32

25/32

 

 

 

 

 

 

 

 

 

 

 

 

(Hole for full

1-37/64

3-35/64

 

 

 

 

 

 

 

 

 

 

 

 

circumference)

 

 

 

 

 

 

 

 

 

 

 

 

1-57/64

2-23/64

 

 

 

 

 

 

 

 

 

5-1/8

 

 

 

 

 

 

 

 

 

 

 

 

 

pitch)

 

 

 

 

 

 

Table 3-5

16-17/32 15-35/64

Unit: in.

27/64-11

 

bolt

 

 

 

 

 

 

36

2-43/64

 

nspeion

 

 

 

 

 

 

Length

A

B

 

C

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

Electrical component box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

17-23/32

16-47/64

3-55/64

2

 

(Sus

 

 

4-ø25/32 hole for

 

 

 

 

 

 

 

 

-5/3

 

 

1-13/16

 

 

 

 

 

 

 

 

 

 

 

 

suspension bolt

 

 

 

 

 

 

 

 

3

 

 

 

4 3-15/16

 

Refrigerant liquid line (ø3/8 or ø1/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16 - ø1/8

 

 

 

= 15-3/4

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant gas line (ø3/4 or ø5/8)

 

 

 

 

 

 

(Hole for full

 

19-11/16

 

 

 

 

 

 

 

 

circumference)

 

 

 

Power supply outlet

 

 

 

 

 

 

 

 

19/32

38-37/64 (Suspension bolt pitch)

19/32

Drain connection (25A, O.D. 1-1/4")

 

 

 

 

 

 

 

Duct connection for suction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24-13/32

 

 

 

 

39-49/64

 

Duct connection for discharge

 

 

 

1 5/-232

 

19-11/16

2-3/4

5/-232

 

 

15/16-3

Inter-unit control wiring

55/64-3

2311/

 

 

 

 

1/3-132

1-3/8

37

 

15/16-3

 

 

 

25/64

25/64

 

 

 

 

 

 

 

 

 

 

12-13/64

 

 

 

 

11-13/16 B

 

 

 

 

 

 

1-

A

 

 

 

 

 

 

 

 

 

 

 

 

-25/32

15/16-3

 

 

15/16-3

 

 

 

 

 

 

Drain pan

Unit: in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3-78

44

Image 44
Contents Optional Controllers R410A Models Indoor UnitsOutdoor Units Special Precautions …In a Room…In Moist or Uneven Locations …In an Area with High WindsCheck of Density Limit Care regarding tubing Be sure to recharge the refrigerant only in liquid formDifferent tools required Manifold gauge Vacuum pumpCompressor specifications are different Single-outlet valveExisting tubing cannot be used especially R22 R410AContents HOW to Process Tubing AIR PurgingTest RUN AppendixGeneral Concealed Duct 4-Way Air Discharge Semi-Concealed1-Way Air Discharge Semi-Concealed Concealed Duct High-Static Pressure Ceiling-MountedWall-Mounted Tubing Size Main Tubing Size LA11 Straight Equivalent Length of Joints Items Marks Contents Tubing LengthInstalling Distribution Joint Pay special attention to anyLocation, such as a basement Can accumulate, since refrigOptional Distribution Joint Kit APR-P160BATightening torque for valve stem cap 240 280 lbs · Example Main tubing Distribution joint tubingSelecting the Installation Site Indoor UnitCeiling-Mounted Type Wall-Mounted TypeInstallation space Case of multiple installationsInstalling the Unit in Heavy Snow Areas Precautions for Installation in Heavy Snow AreasAir Discharge Chamber for Top Discharge Countermeasures against snow and windCHX03652/06052 WindFront and both sides must remain open 28-13/16 17-23/32 47-19/32 Obstacle to the rear of unit Obstacle to the front of unitInstallation in front-rear rows Obstacles to the front and rear of unitHOW to Install the Indoor Unit Suspending the Indoor UnitPlacing the Unit Inside the Ceiling 12, 18, 24Installing the Drain Piping PVC pipe must be purchased separately.On the indoor control board Start when you short the pinBe careful since the fan will Removing the corner cover Installing the Ceiling Panel Main unit Gaps Ceiling surfaceWiring the Ceiling Panel Checking After Installation When Removing the Ceiling Panel for ServicingAdjusting the Auto Flap Special Remarks DC Fan Tap Change ProcedureFollow the diagrams to make the holes in the ceiling Full-scale Installation diagram Suspension lug 25/32 1 Suspension bolts Tubing side Unit Ceiling Material 25/32 Be careful since the fan will start Electrical Power Wiring Wiring connectionsWiring Appearance Part nameRemoving the intake grille Removing the side panelMust be no gap Indoor unit Ceiling surface Ceiling panel Installing the side panel and intake grille Installing the intake grilleOther Check after installation If a wireless remote controller is usedType Length Number of duct flangesEnough to support the weight of the unit It is important that you use extreme careSupporting the indoor unit inside Ceiling. Ensure that the ceiling is strongPipe Increasing the Fan Speed How to read the diagramShort the pin on the indoor control board 78 and -5 show the detailed dimensions Enough to suport the weight of the unit Indoor Fan Performance How to Read the Diagram Refrigerant tubing drain hose position UnitWeight of the unit. Before Wall and ceiling side opening positionIt is important that you use Indoor unit from the ceilingInside Rear outlet port Duct for Fresh AirShaping the Tubing How to carry out power supply wiring When removing the fasteningBracket from the cover BracketSelecting and Making a Hole Removing the Grille to Install the Indoor Unit If the Wall is Brick, Concrete or SimilarRemoving the grille Attaching the grilleInstalling the Drain Hose Do not supply power to the unit or operateIt until all tubing and wiring to the outdoor Right-rear tubingKHX0752 / 0952 / 1252 KHX2452HOW to Install the Outdoor Unit Electrical Wiring General Precautions on WiringCHX03652 For field wiring rules, please refer CHX06052Wiring System Diagram U, D, T TypeOutdoor unit That all wiring is tightly How to connect wiring to the terminal For stranded wiringResult in unit malfunction Fire hazard may alsoFlaring Procedure with a Flare Tool HOW to Process TubingConnecting the Refrigerant Tubing Use of the Flaring Method Tube diameter Tightening torque Tube thickness Approximate Insulating the Refrigerant Tubing Tubing Insulation Two tubes arranged togetherInsulation material After a tube has beenFinishing the Installation Taping the TubesAIR Purging Evacuation Finishing the job Use a cylinder designed forCharging additional refrigerant Test RUN Test Run Procedure Items to Check Before the Test Run YESOutdoor Unit PCB Setting Examples of the No. of indoor units settings Auto Address Setting Basic wiring diagram Example Automatic Address Setting from the Outdoor UnitIf link wiring is used Automatic Address Setting no compressor operation Automatic Address Setting from Outdoor UnitAutomatic Address Setting in Heating Mode Setting in heating mode beginsAutomatic Address Setting in Cooling Mode Automatic Address Setting from the Remote ControllerDisplay during automatic address setting Checking the indoor unit addresses If 1 indoor unit is connected to 1 remote controllerRemote Controller Test Run Settings LED Alarm Care and Cleaning Type 4-WAYLatch Air intake Safety chain Grille Bolt screws Tips for Energy SavingRemove the air filter from the air intake grille Water drain Air outlet Air intake Ceiling panel optionalTroubleshooting Electrical box Air outlet side duct flange Concealed Duct High-Static Pressure Type U, D TypeCanvas duct optional Troubleshooting CEILING-MOUNTED Air intake grille air intakeOr soot Type Wall-Mounted Tips for Energy Saving

85464359981002 specifications

The Sanyo 85464359981002 is a versatile and innovative product that has garnered attention in its respective market for its blend of performance, efficiency, and advanced technology features. This product is designed to cater to the demanding needs of consumers who prioritize quality and functionality in their daily lives.

One of the standout features of the Sanyo 85464359981002 is its energy efficiency. It is engineered to operate with minimal energy consumption while still delivering exceptional performance. This aspect is particularly significant given the growing concerns regarding energy usage and environmental sustainability. The model incorporates state-of-the-art technologies that optimize power usage without compromising on functionality.

The design of the Sanyo 85464359981002 focuses on user-friendliness and convenience. This product is equipped with an intuitive interface that makes it simple for users of all experience levels to operate and adjust settings as needed. Additionally, the lightweight construction enhances portability, allowing for easy transportation from one location to another.

Another notable characteristic is the advanced materials used in its construction. The Sanyo 85464359981002 is built to withstand the rigors of everyday use, ensuring durability and longevity. This quality makes it a smart investment for consumers looking for a reliable solution that won't require frequent replacements.

Connectivity is also a key feature of the Sanyo 85464359981002. It includes multiple ports and connectivity options that allow users to integrate the product with a variety of devices. This versatility enables seamless interaction with smartphones, tablets, and other technologies, ensuring that the Sanyo 85464359981002 can adapt to different environments and user needs.

The performance capabilities of the Sanyo 85464359981002 are impressive, emphasizing precision and speed. Whether it's delivering high-quality output or ensuring rapid operation, this product stands out in its field. These performance enhancements are supported by advanced technology that streamlines processes and improves overall productivity.

In conclusion, the Sanyo 85464359981002 exemplifies a well-rounded product that embodies modern design, energy efficiency, durability, and adaptability. Its array of features and advanced technologies makes it an attractive choice for consumers seeking quality and reliable performance in their daily routines.