COMMUNICATION
Remote Operation by Telephone
The control panel can be operated while you are away from home. You can have access to the control panel with any touch tone phone to perform a variety of operations, listed below.
-Arm
-Disarm
-Lights, Home Applicances on / off (Requires additonal Control Module)
-Garage door open / close (Requires additional Garage Door Receiver)
-System status
-Disconnect
There are 2 ways you can have access to the remote phone operation:
1.You can call the control panel when you are away from home; or
2.When the control panel calls you during emergency.
To access the control panel away from home
Calling in when you are away from home
1.Call your home phone number, or the number that the phone line of the control panel is connected to.
2.Hang up after the second ring.
3.Wait at least 10 seconds, but not more than 40 seconds, then call the phone number again.
4.The control panel will pick up the phone call and request for a valid user password, you will hear “Enter Password”. You can enter either the Master Password or Secondary Password. If the password is correct, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”.
5.Once the password is accepted, you can have access to all the operations listed below.
ADVANCED PROGRAMMING
Auto Mute
When a sensor is triggered in alert mode, audio warning will be emitted, either beep or alarm. For example, if a door is opened, the beep will not stop until the door is closed. If the door is open for 2 hours, the beep will go on for 2 hours.
There are times that this is not desired. With the auto mute feature enabled, the beep will go on for only 20 seconds. After that, even if the sensor remains open, the beep will stop only the zone LED will flash to indicate the sensor is triggered. Beep will go on again if the sensor is closed and opened again.
Note: Auto Mute only functions when the control panel is in alert mode (disarmed). If the control panel is in alarm mode (armed), a triggered sensor will result in entry delay or instant alarm.
Factory Default: This feature was disabled for all zones at the factory.
To enable auto mute feature, follow the instructions below.
Step | Keys | Function | Description | Note |
|
|
|
|
|
1 | [PROG] | Enter Program- | Enter master | 3 beeps for valid |
| [MPIN] | ming mode | password to | password. 1 long beep |
|
|
| programming mode | for invalid password. |
|
|
|
|
|
2 | [6] | Select Auto Mute |
| After [6] is entered, some |
|
| Enable / Disable |
| zone LEDs will flash or |
|
|
|
| stay on. This indicates |
|
|
|
| whether Auto Mute is |
|
|
|
| enabled or disabled. |
|
|
|
|
|
3 | Disable | Select which | Refer to the diagram | If auto mute is enabled, |
| Auto Mute: | zone you would | below to select the | that zone LED will be on. |
| [1] to [5] | like to enable / | appropriate setting. | If it is disabled, the LED |
|
| disable auto mute. |
| will flash. You are allow |
| Enable |
|
| to make multiple changes |
| Auto Mute: |
|
| before terminating |
|
|
| programming mode. | |
| [6] to [0]. |
|
| |
|
|
|
|
|
4 | [PROG] | Terminate |
| PROG LED will be off, and |
| when | programming |
| you will hear 3 beeps. |
| finished. | mode. |
|
|
|
|
|
|
|