HOME AUTOMATION
Event Trigger
You can control up to 5 different devices not only manually, but also automatically. It is called Event Trigger. That means when a sensor is triggered, the control panel will transmit a signal to activate the designated control module. Applications include:
INSTALLATION
Note:
- It’s not recommended to program 911, fire station or any emergency services |
phone numbers into any of the phone memories without their approvals. |
- Ensure to program a valid phone number and write down the programmed |
phone number on the System Setting Information provide on the back of this |
user's instructions. |
-Lights on when you open the front door (walking into a room, lights on automatically), this is called "Event Trigger on".
-Lights off when you open a door. (walk away from a room, turns lights off), this is called "Event Triggered off".
Event trigger is only applicable to the sensor(s) and control module in the same zone. For example, you can program control module 1 to be on or off when zone 1 sensor(s) is triggered. You can also program control module 2 to be on / off when zone 2 sensor(s) is triggered.
Factory Default: This feature is disabled for all zones at the factory.
Event Trigger On
Event Trigger Off
- You may quit programming by pressing [PROG] button at any time. |
- If no phone number is programmed, the ARM LED will continue to flash. |
Testing Phone Numbers:
After you have programmed all the phone numbers, you should verify you have programmed the phone numbers correctly. This can be done by triggering the alarm silently by entering the duress password, so it dials to the programmed phone numbers without sounding the alarm.
Note:
You must inform the recipients of the programmed phone numbers, so they know what to expect when they receive the phone call from the control panel during an emergency. These recipients should know the password to your control panel if you expect them to have remote access of your control panel. For more informa- tion regarding receiving the emergency call, please refer to page 23.
To change the event trigger setting follow the instructions below.
Step | Keys | Function | Description | Note | |
1 | [PROG] | Enter Program- | Enter master | 3 beeps for valid | |
ming mode | password to | password. 1 long beep | |||
| [MPIN] | ||||
|
|
| programming | for invalid password. | |
|
|
| mode |
| |
2 | [7] | Select Event |
| After [7] is entered, | |
|
| Trigger |
| some zone LEDs will be | |
|
|
|
| off, on or flash. This | |
|
|
|
| indicates the setting of | |
|
|
|
| event trigger. | |
|
|
|
|
| |
3 | Disable Event | Select which | Refer to the | If event trigger “ON” is | |
| Trigger: [1] to | zone you would | diagram below | enabled, that zone LED will | |
| [5] | like to enable / | to select the | be on. If event trigger “OFF” | |
|
| disable event | appropriate | is enabled, that zone LED | |
| Enable Event | trigger. | setting. | will flash. If it is disabled, the | |
|
|
| zone LED will be off. You are | ||
| Trigger: [6] to |
|
| ||
|
|
| allowed to make multiple | ||
| [0]. |
|
| ||
|
|
| changes before terminating | ||
|
|
|
| ||
|
|
|
| programming mode. | |
|
|
|
|
| |
4 | [PROG] | Terminate |
| PROG LED | |
| when | programming |
| will be off. | |
| finished. | mode. |
|
|
1.Press [Arm], you should hear beeping from the control panel.
2.Press [3838]. Beeping will stop, and the control panel will start to dial the first number.
3.The called party should receive the call. Pick up the call and say “Hello”, an emergency message “System Panic” will be played. If the programmed phone doesn’t ring, ensure the phone number is programmed correctly, or reprogram this phone number again.
4.After the emergency message has been played for several times (depending on how many times it was programmed), the called party will hear “Enter Password”.
5.Enter either the master password or secondary password. If the correct password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”.
6.Press [0][#] on the telephone to hang up.
7.The control panel will start to dial the next programmed phone number.
Note:
-Refer to page 23 [Receiving the Emergency Call] for more info on how to react to an emergency call.
-The password is treated as a confirmation of the emergency message. Once a valid password is entered, the control panel will not call that number again, it will proceed to the next number.
-If any one of the called parties disarms the control panel, the control panel will not continue to dial the remaining phone numbers.
-After calling all the programmed phone numbers, the control panel will be back to the previous operation mode.