Thermo Products PGT16-160 TWO Piece Mounting Plate, Side View Burner Insertion Illustration PGT

Page 14

All installations and services must be performed by qualified service personnel.

TWO PIECE MOUNTING PLATE

When mounting the burner, the upper mounting plate must be removed to provide access to the area in front of the combustion chamber. The combustion chamber can then be moved forward or backward slightly to allow for adjustment in positioning the burner tube. Do not allow the burner tube or end cone to physically touch the chamber, as excessive heat transfer could result in distortion of the tube or end cone, or both.

Once the burner tube is properly positioned, at most 1/4 inch back from the inside surface of the combustion chamber wall, the loose-fill insulation that is included should be lightly placed around the burner tube between the front of the combustion chamber and the burner mounting plate. (DO NOT PACK THE INSULATION DOWN). The loose-fill insulation should be placed in such a fashion that the surface of the insulation is sloped from the top of the combustion chamber to the top of the lower mounting plate. The purpose of the loose insulation is to help protect the burner tube, mounting plates and vestibule area from internal temperatures.

NOTE: Do not place loose insulation around chamber sides and back.

(SIDE VIEW)

BURNER INSERTION ILLUSTRATION (PGT)

CAUTION: When installing the burner, it should be noted that the loose fill insulation and fiber chambers are made with ceramic fibers. Currently, there are no known chronic health effects in humans associated with long term exposure to ceramic fibers. The International Agency of Research on Cancer (IARC) based on its review of studies that injected ceramic fiber into the abdomens of hamsters and rats have classified fibrous glass wool, mineral wool (both rock wool and slag wool) and ceramic fiber as group 2B carcinogens. A group 2B agent is considered by IARC

12

Image 14
Contents Models Table of Contents Section Page Page Codes and Clearances II. General InstallationGeneral Instructions Construction MaterialsMinimum Clearances to Combustible Materials Furnace Location and Combustion AIRMAKE-UP AIR VentingExample Vent Dampers Condensing in the ChimneyReplacing AN Existing Furnace from a Common Vent General GAS PipingInstallation of Natural GAS Piping Typical Piping for TWO Stage Regulation Installation of Liquified Petroleum GAS LP PipingBlack Pipe Size for Natural GAS TOP View Burner Insertion Illustration PGL Burner InstallationCopper Tubing Size for Liquified Petroleum Gases TWO Piece Mounting Plate Side View Burner Insertion Illustration PGTMidco RE32 Burner Adjustment Horizontal Furnace PositionsDraftoverfire Natural GASGAS Requirements and Sizing of Duct Work Duct Sizes for HOMES, Quiet Offices or Similar Installations Duct WORK/AIR Conditioning Filters PGT Horizontal Units PGL LowboyFAN and Limit Position and Location Wiring FAN & Limit Location with H-COILLatest Edition Page Page Page Page Latest Edition Operating Instructions Adjustment of BTU Input RateII. Starting the Unit A. Initial Start UP Burner CombustionPage Furnace Checkout Procedure IV. Installers Instructions to UserDealer Maintenance Electrical Cleaning Heat ExchangerVI. Troubleshooting VII. Replacement Parts Page Page

PGL33-250, PGL39-400, PGL37-312, PGT11-125, PGL20-180 specifications

Thermo Products offers a robust lineup of heating devices designed to meet diverse industrial requirements. Among these, models PGL33-250, PGT5-100, PGL39-400, PGL20-180, and PGT11-125 stand out for their innovative technology and exceptional performance.

The PGL33-250 is particularly noted for its high output, making it an ideal choice for larger industrial applications. With an advanced heating element, it ensures rapid temperature increases while maintaining consistent heat distribution. This model is equipped with smart control systems that allow for remote monitoring and adjustments, enhancing operational efficiency.

Next in the lineup is the PGT5-100, a compact yet powerful solution perfectly suited for smaller spaces where efficiency is key. It features an energy-efficient design that reduces operational costs without compromising on performance. The PGT5-100 includes built-in overheat protection, ensuring safe operation even in demanding environments.

The PGL39-400 takes versatility to the next level. Its dual-mode heating capabilities allow users to switch between high-efficiency and high-output settings, catering to varying workload requirements. The advanced insulation technology employed in this model minimizes heat loss, thereby maximizing energy efficiency and reducing environmental impact.

In the mid-range category, the PGL20-180 offers robust performance with a focus on user-friendly features. This model includes a sophisticated digital control panel, providing real-time temperature readings and programmable settings. Its lightweight design makes installation straightforward, while its durability ensures long-term reliability.

Finally, the PGT11-125 stands out for its innovative thermal regulation system. This system adapts the heating output based on real-time environmental conditions, ensuring optimal performance at all times. The PGT11-125 is also constructed using high-quality materials that resist corrosion and wear, making it suitable for various industrial applications.

Collectively, these models from Thermo Products exemplify the company's commitment to quality and technological advancement. With features such as smart controls, advanced insulation, and dual-mode operation, these heating solutions not only offer efficient performance but also contribute to energy savings and a reduced carbon footprint. As industries continue to evolve, Thermo Products remains at the forefront, providing reliable and innovative heating solutions for all industrial needs.