Thermo Products PGL37-312, PGT16-160, PGT5-100, PGL20-180 Installation of Natural GAS Piping

Page 11

All installations and services must be performed by qualified service personnel.

Piping from the natural gas meter to the furnace shall be in accord with requirements of the local utility. Piping from the LP tank to the furnace must follow the recommendations of the gas supplier.

1.A readily accessible, certified manual shut off valve with a non-displaceable rotor member should be installed within six feet of the gas equipment it serves. A union or flanged connection shall be provided downstream from the manual valve to permit removal of controls. A 1/8" N.P.T. plugged tapping, that is accessible for connecting a test gage, must be installed immediately upstream of the gas connection to the furnace. Unions must be of a ground joint type or flanged-joint using a gasket resistant to LPG. Pipe dope or tape certified to be resistant to the action of liquified petroleum gases should be used on all threaded joints.

2.A drip leg must be used on both LP and natural gas installations prior to the furnace to trap oil, condensate and other impurities which might otherwise lodge in the gas valve or plug the burner orifice. When there is excessive condensation between the gas meter and the furnace, a drip leg shall be provided at the outlet of the gas meter. Failure to install a drip leg may void the limited warranty on the furnace.

NOTE: All gas piping must be leak tested using a soap and water solution (if the gas is turned on) following the procedure outline in this section (caution must be taken not to wet electronic components). A final test for gas leakage must be made after purging the gas line. This test must be conducted with the unit operating and should include the furnace piping and gas valve. Never use an open flame to check for a gas leak.

IMPORTANT: Care must be taken not to wet electronic components during leak test. Wetting the primary ignition module may damage its circuitry and cause a hazardous situation. If wetting occurs, dry moisture from all leads, terminals, and electronic components using a hair dryer or similar means or wait at least 24 hours for the circuit to fully dry before energizing the burner circuit.

The furnace and its individual gas valve must be disconnected from the gas supply during pressure testing of the gas supply system at pressures in excess of 1/2 PSIG or 14.0" wc.

I. INSTALLATION OF NATURAL GAS PIPING

The installation of the gas piping and the following test procedures must be performed by a qualified installer or service person.

1.The following chart is to be used as a guide in sizing natural gas supply piping. The input loading of all gas appliances installed on any main or trunk line must be totaled to determine its needed carrying capacity.

9

Image 11
Contents Models Table of Contents Section Page Page Construction Materials II. General InstallationGeneral Instructions Codes and ClearancesFurnace Location and Combustion AIR Minimum Clearances to Combustible MaterialsVenting MAKE-UP AIRExample Condensing in the Chimney Vent DampersGeneral GAS Piping Replacing AN Existing Furnace from a Common VentInstallation of Natural GAS Piping Typical Piping for TWO Stage Regulation Installation of Liquified Petroleum GAS LP PipingBlack Pipe Size for Natural GAS TOP View Burner Insertion Illustration PGL Burner InstallationCopper Tubing Size for Liquified Petroleum Gases Side View Burner Insertion Illustration PGT TWO Piece Mounting PlateHorizontal Furnace Positions Midco RE32 Burner AdjustmentDraftoverfire Natural GASGAS Requirements and Sizing of Duct Work Duct Sizes for HOMES, Quiet Offices or Similar Installations Duct WORK/AIR Conditioning PGT Horizontal Units PGL Lowboy FiltersFAN and Limit Position and Location FAN & Limit Location with H-COIL WiringLatest Edition Page Page Page Page Latest Edition Burner Combustion Adjustment of BTU Input RateII. Starting the Unit A. Initial Start UP Operating InstructionsPage IV. Installers Instructions to User Furnace Checkout ProcedureCleaning Heat Exchanger Dealer Maintenance ElectricalVI. Troubleshooting VII. Replacement Parts Page Page

PGL33-250, PGL39-400, PGL37-312, PGT11-125, PGL20-180 specifications

Thermo Products offers a robust lineup of heating devices designed to meet diverse industrial requirements. Among these, models PGL33-250, PGT5-100, PGL39-400, PGL20-180, and PGT11-125 stand out for their innovative technology and exceptional performance.

The PGL33-250 is particularly noted for its high output, making it an ideal choice for larger industrial applications. With an advanced heating element, it ensures rapid temperature increases while maintaining consistent heat distribution. This model is equipped with smart control systems that allow for remote monitoring and adjustments, enhancing operational efficiency.

Next in the lineup is the PGT5-100, a compact yet powerful solution perfectly suited for smaller spaces where efficiency is key. It features an energy-efficient design that reduces operational costs without compromising on performance. The PGT5-100 includes built-in overheat protection, ensuring safe operation even in demanding environments.

The PGL39-400 takes versatility to the next level. Its dual-mode heating capabilities allow users to switch between high-efficiency and high-output settings, catering to varying workload requirements. The advanced insulation technology employed in this model minimizes heat loss, thereby maximizing energy efficiency and reducing environmental impact.

In the mid-range category, the PGL20-180 offers robust performance with a focus on user-friendly features. This model includes a sophisticated digital control panel, providing real-time temperature readings and programmable settings. Its lightweight design makes installation straightforward, while its durability ensures long-term reliability.

Finally, the PGT11-125 stands out for its innovative thermal regulation system. This system adapts the heating output based on real-time environmental conditions, ensuring optimal performance at all times. The PGT11-125 is also constructed using high-quality materials that resist corrosion and wear, making it suitable for various industrial applications.

Collectively, these models from Thermo Products exemplify the company's commitment to quality and technological advancement. With features such as smart controls, advanced insulation, and dual-mode operation, these heating solutions not only offer efficient performance but also contribute to energy savings and a reduced carbon footprint. As industries continue to evolve, Thermo Products remains at the forefront, providing reliable and innovative heating solutions for all industrial needs.