Thermo Products PGT5-100, PGT16-160 Horizontal Furnace Positions, Midco RE32 Burner Adjustment

Page 15

All installations and services must be performed by qualified service personnel.

to have the possibility of being carcinogenic to humans. IARC has also classified these fibrous materials as group 2A carcinogens when they have undergone long term exposure to temperatures greater than 18000F. A group 2A agent is considered to have the probability of being carcinogenic to humans. For these reasons, we suggest the use of a 3M 9900, 3M 8710, or equivalent mask when working with any ceramic fiber products. For further information, contact the Manager of Customer Service for Rex Roto Corporation at (517) 324-7533.

HORIZONTAL FURNACE POSITIONS:

The horizontal furnace may be turned end for end, or rotated, making the top into the bottom, as shown below.

After the furnace has been positioned, the bottom burner mounting stud must be removed before mounting the burner. Also, the fan & limit and its mounting bracket must be properly positioned once the unit is in place. (See section N on fan & limit position and location).

MIDCO RE32 BURNER ADJUSTMENT

In order to properly set-up a furnace with a Midco RE32 burner,Thermo Pride’s recommendation is to utilize a Modified version of Midco’s instruction together with combustion equipment and a carbon monoxide detector. It must be emphasized that the gas equipment is operating properly and safely requires combustion equipment and a carbon monoxide detector.

1.Check unit for signs of sooting and clean as necessary, the furnace heat exchanger, flue, and chimney.

2.Open the air adjustment completely. Turn adjustment screw counterclockwise until it stops.

3.To achieve a starting point for proper combustion, adjust the air adjustment screw according to the chart below For the applicable Thermo Pride furnace utilizing the Midco RE32 burner.

13

Image 15
Contents Models Table of Contents Section Page Page Construction Materials II. General InstallationGeneral Instructions Codes and ClearancesFurnace Location and Combustion AIR Minimum Clearances to Combustible MaterialsVenting MAKE-UP AIRExample Condensing in the Chimney Vent DampersGeneral GAS Piping Replacing AN Existing Furnace from a Common VentInstallation of Natural GAS Piping Installation of Liquified Petroleum GAS LP Piping Black Pipe Size for Natural GASTypical Piping for TWO Stage Regulation Burner Installation Copper Tubing Size for Liquified Petroleum GasesTOP View Burner Insertion Illustration PGL Side View Burner Insertion Illustration PGT TWO Piece Mounting PlateHorizontal Furnace Positions Midco RE32 Burner AdjustmentNatural GAS GASDraftoverfire Requirements and Sizing of Duct Work Duct Sizes for HOMES, Quiet Offices or Similar Installations Duct WORK/AIR Conditioning PGT Horizontal Units PGL Lowboy FiltersFAN and Limit Position and Location FAN & Limit Location with H-COIL WiringLatest Edition Page Page Page Page Latest Edition Burner Combustion Adjustment of BTU Input RateII. Starting the Unit A. Initial Start UP Operating InstructionsPage IV. Installers Instructions to User Furnace Checkout ProcedureCleaning Heat Exchanger Dealer Maintenance ElectricalVI. Troubleshooting VII. Replacement Parts Page Page

PGL33-250, PGL39-400, PGL37-312, PGT11-125, PGL20-180 specifications

Thermo Products offers a robust lineup of heating devices designed to meet diverse industrial requirements. Among these, models PGL33-250, PGT5-100, PGL39-400, PGL20-180, and PGT11-125 stand out for their innovative technology and exceptional performance.

The PGL33-250 is particularly noted for its high output, making it an ideal choice for larger industrial applications. With an advanced heating element, it ensures rapid temperature increases while maintaining consistent heat distribution. This model is equipped with smart control systems that allow for remote monitoring and adjustments, enhancing operational efficiency.

Next in the lineup is the PGT5-100, a compact yet powerful solution perfectly suited for smaller spaces where efficiency is key. It features an energy-efficient design that reduces operational costs without compromising on performance. The PGT5-100 includes built-in overheat protection, ensuring safe operation even in demanding environments.

The PGL39-400 takes versatility to the next level. Its dual-mode heating capabilities allow users to switch between high-efficiency and high-output settings, catering to varying workload requirements. The advanced insulation technology employed in this model minimizes heat loss, thereby maximizing energy efficiency and reducing environmental impact.

In the mid-range category, the PGL20-180 offers robust performance with a focus on user-friendly features. This model includes a sophisticated digital control panel, providing real-time temperature readings and programmable settings. Its lightweight design makes installation straightforward, while its durability ensures long-term reliability.

Finally, the PGT11-125 stands out for its innovative thermal regulation system. This system adapts the heating output based on real-time environmental conditions, ensuring optimal performance at all times. The PGT11-125 is also constructed using high-quality materials that resist corrosion and wear, making it suitable for various industrial applications.

Collectively, these models from Thermo Products exemplify the company's commitment to quality and technological advancement. With features such as smart controls, advanced insulation, and dual-mode operation, these heating solutions not only offer efficient performance but also contribute to energy savings and a reduced carbon footprint. As industries continue to evolve, Thermo Products remains at the forefront, providing reliable and innovative heating solutions for all industrial needs.