HP FC 1GB/2GB 16B Memory Specifications, Optical Port Specifications, Serial Port Specifications

Page 41

Product Specifications

A

Table A-4

General Specifications (Continued)

 

 

Port to port latency

Less than 2 microseconds with no contention (destination port

 

 

is free)

 

 

 

Data transmission range

Up to 500 m (1,625 ft.) for short-wavelength optical link

 

 

Up to 10 km (32,820 ft.) for long-wavelength optical link

 

 

 

Immunity

 

IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge

 

 

IEC 61000-4-3 Severity Level 3 for Radiated Fields

 

 

IEC 61000-4-4

Severity Level 3 for Fast Transients

 

 

IEC 61000-4-5

Severity Level 3 for Surge Voltage

 

 

IEC 61000-4-6

Conducted Emissions

 

 

IEC 61000-4-11 Voltage Variations

 

 

 

 

Memory Specifications

The FC 16B has the following memory:

Main Memory: 16 MB per switch

Flash Memory: 16MB of 16-bit wide memory, stored in 2 banks of 8M-bytes each

Boot Flash: 512K bytes of 8-bit for system boot

The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and receive bandwidth to all Fibre Channel ports at all times.

Optical Port Specifications

The optical ports in the FC 16B are compatible with SWL (short wave-length) and LWL (long wave-length) SFPs (small form factor pluggable media) and SFP-compatible cables. The strength of the signal is determined by the type of SFP in use.

The ports meet all required safety standards. For more information about these standards, see Regulatory Compliance on page A-7.

The ports are capable of operating at 2.125 Gbps or 1.0625 Gbps. Each port has a SerDes (serializer/de-serializer) which accepts 10-bit wide parallel data and serializes it into a high-speed serial stream. The parallel data is expected to be “8B/10B” encoded data or equivalent.

Serial Port Specifications

The serial port has an RS-232 connector, and is located in the SFP media side of the switch.

Note: For dust and ESD (electrostatic discharge) protection, a cover is provided for the serial port and should be kept on the port whenever the serial port is not in use.

The serial port can be used to connect to a computer workstation to configure the switch IP address without connecting to the fabric. The serial port’s parameters are 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.

HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference Guide

A-5

Image 41 Contents
Page Warranty Contents Glossary Index About This Guide PrefaceGetting Help Related PublicationsUse of Notes, Cautions, and Warnings Getting Software UpdatesViii Overview Introducing the HP Surestore FC 1Gb/2GbSwitch 16B SFP Media Side Monitoring and Managing the FC 16B Introducing the HP Surestore FC 1Gb/2Gb Switch 16B Safety Guidelines Installing and Configuring the HP SurestoreFC 1Gb/2Gb Switch 16B Installing the Switch as a Stand-Alone Unit Package ContentsFC 16B Rack-Mounted Switch Installing the Switch in a RackPage Installing the Rear Rail-Tray Brackets HP Rack To install the switch in a rackInstalling the Tinnerman Clips HP Rack Installing the Rubber Washers Assembling the Inner Rails To configure the FC 16B and connect it to a fabric Configuring and Connecting the SwitchA Windows 95, 98, 2000, or NT environment Page Saving the System Configuration Files Backing up the Switch Configuration Settings Next Steps Setting QuickLoop Mode on PortsHP Surestore VA Private Loop Devices Interpreting LED Activity Operating the HP Surestore FC 1Gb/2Gb Switch 16BTurning the FC 16B On and Off LEDs On the SFP Media Side Above LEDs On the Power Supply Side Supply Interpreting Post ResultsDiagnostic Tests Maintaining the SwitchField-Replaceable Units FRUs Operating the HP Surestore FC 1Gb/2Gb Switch 16B Switch Components Product SpecificationsDimension Value Weight and Physical DimensionsFacility Requirements Table A-1Environmental Requirements Power Supply SpecificationsTable A-4 General SpecificationsSpecification Description Serial Port Specifications Memory SpecificationsOptical Port Specifications PIN Post SpecificationsSignal Description FCC EMC Statement USA EMC Statement Canada Regulatory ComplianceCertification and Classification Information Product Information Declaration of Conformity Glossary BER Credit Cut-through Data Word Defined Zone ConfigurationBlock BroadcastEdtov DLSFlogi FC-AL-3 FC-FLA FCP FC-PH-1, 2, 3 FC-PI FC-PLDA FC-SW-2FRU FSPGbic FspfHBA IODLIP Lmtov JbodLpsm LWL MIBPost PlogiRAID RatovRrtov RscnSWL SnmpSNS WWN UDP ULP UlptovEMI IndexNvram A-2 Index-3 Index-4