HP FC 1GB/2GB 16B manual Plogi, Post

Page 53

Multimode

N_Port

Name Server

NL_Port

Node

Node Name

Non- participating Mode

Nx_Port

Ordered Set

A fiber optic cabling specification that allows up to 500 meters between devices.

Node Port; a port on a node that can connect to a Fibre Channel port or to another N_Port in a point-to-point connection. See also NL_Port, Nx_Port.

Frequently used to indicate Simple Name Server. See also SNS.

Node Loop Port; a node port that has arbitrated loop capabilities. Used to connect an equipment port to the fabric in a loop configuration through an FL_Port. See also N_Port, Nx_Port.

A Fibre Channel device that contains an N_Port or NL_Port.

The unique identifier for a node, communicated during login and port discovery.

A mode in which an L_Port in a loop is inactive and cannot arbitrate or send frames, but can retransmit any received transmissions. This mode is entered if there are more than 127 devices in a loop and an AL_PA cannot be acquired. See also L_Port, Participating Mode.

A node port that can operate as either an N_Port or NL_Port.

A transmission word that uses 8B/10B mapping and begins with the K28.5 character. Ordered sets occur outside of frames, and include the following items:

Frame delimiters Mark frame boundaries and describe frame contents.

Primitive signals Indicate events.

Primitive sequences Indicate or initiate port states.

 

Ordered sets are used to differentiate Fibre Channel control information from data

 

frames and to manage the transport of frames.

Packet

A set of information transmitted across a network. See also Frame.

Participating A mode in which an L_Port in a loop has a valid AL_PA and can arbitrate, send

Modeframes, and retransmit received transmissions. See also L_Port, Non- participating Mode.

Path Selection The selection of a transmission path through the fabric.

Phantom

An AL_PA value that is assigned to an device that is not physically in the loop.

Address

Also known as phantom AL_PA.

Phantom

A device that is not physically in an arbitrated loop but is logically included

Device

through the use of a phantom address.

PLOGI

Port Login; the port-to-port login process by which initiators establish sessions

 

with targets. See also FLOGI.

Point-to-point

A Fibre Channel topology that employs direct links between each pair of

 

communicating entities. See also Topology.

Port_Name

POST

Private

NL_Port

The unique identifier assigned to a Fibre Channel port. Communicated during login and port discovery.

Power On Self-Test; a series of tests run by a switch after it is turned on.

An NL_Port that communicates only with other private NL_Ports in the same loop and does not log into the fabric.

HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference Guide

Glossary-7

Image 53 Contents
Page Warranty Contents Glossary Index About This Guide PrefaceGetting Help Related PublicationsUse of Notes, Cautions, and Warnings Getting Software UpdatesViii Overview Introducing the HP Surestore FC 1Gb/2GbSwitch 16B SFP Media Side Monitoring and Managing the FC 16B Introducing the HP Surestore FC 1Gb/2Gb Switch 16B Safety Guidelines Installing and Configuring the HP SurestoreFC 1Gb/2Gb Switch 16B Installing the Switch as a Stand-Alone Unit Package ContentsFC 16B Rack-Mounted Switch Installing the Switch in a RackPage Installing the Rear Rail-Tray Brackets HP Rack To install the switch in a rackInstalling the Tinnerman Clips HP Rack Installing the Rubber Washers Assembling the Inner Rails To configure the FC 16B and connect it to a fabric Configuring and Connecting the SwitchA Windows 95, 98, 2000, or NT environment Page Saving the System Configuration Files Backing up the Switch Configuration Settings Next Steps Setting QuickLoop Mode on PortsHP Surestore VA Private Loop Devices Interpreting LED Activity Operating the HP Surestore FC 1Gb/2Gb Switch 16BTurning the FC 16B On and Off LEDs On the SFP Media Side Above LEDs On the Power Supply Side Supply Interpreting Post ResultsDiagnostic Tests Maintaining the SwitchField-Replaceable Units FRUs Operating the HP Surestore FC 1Gb/2Gb Switch 16B Switch Components Product SpecificationsDimension Value Weight and Physical DimensionsFacility Requirements Table A-1Environmental Requirements Power Supply SpecificationsTable A-4 General SpecificationsSpecification Description Serial Port Specifications Memory SpecificationsOptical Port Specifications PIN Post SpecificationsSignal Description FCC EMC Statement USA EMC Statement Canada Regulatory ComplianceCertification and Classification Information Product Information Declaration of Conformity Glossary BER Credit Cut-through Data Word Defined Zone ConfigurationBlock Broadcast Edtov DLSFlogi FC-AL-3 FC-FLA FCP FC-PH-1, 2, 3 FC-PI FC-PLDA FC-SW-2FRU FSPGbic FspfHBA IODLIP Lmtov JbodLpsm LWL MIBPost PlogiRAID RatovRrtov RscnSWL SnmpSNS WWN UDP ULP UlptovEMI IndexNvram A-2 Index-3 Index-4