Table 6-1 Control-panel messages (continued)
Control panel message | Description | Recommended action | |
|
|
|
|
| ● | INTERNAL DISK |
|
| ● | EIO |
|
[FS] Is write protected | The disk device is protected so no new files |
| can be written to it. |
Fonts and forms cannot be stored on the disk when the disk is
Authentication required | Authentication has been enabled for this | Type the user name and password, or contact | |
| feature or destination. A username and | the network administrator. | |
| password are required. |
|
|
|
|
| |
Authentication required to use this | A user name and password are required. | Type the user name and password, or contact | |
feature |
| the network administrator. | |
|
|
| |
Card slot <X> not functional | The EIO slot is not functioning correctly. | 1. Reseat the EIO card. | |
|
| 2. | Reseat the formatter. |
|
| 3. | If the error persists, use a different EIO |
|
|
| card. |
|
|
| |
Document feeder bin full | The document feeder output bin holds 50 | Usually, emptying the ADF output bin clears | |
| sheets of paper. The device stops when the | this message. If the message persists, check | |
| bin is full. | the following items: | |
|
| 1. | Verify that the ADF |
|
|
| sensor flag can move freely. |
|
| 2. | Verify that the connector at the sensor |
|
|
| flag is seated correctly. |
|
| You can use the scanner tests | |
|
| (Troubleshooting > Scanner Tests) to test | |
|
| this sensor. Lift up on the sensor flag to | |
|
| simulate the output bin being full. Observe | |
|
| whether the status changes on the control- | |
|
| panel display. If the status does not change, | |
|
| make sure that the connectors are firmly | |
|
| seated. Clean or replace the sensor if | |
|
| necessary. | |
|
|
| |
Document feeder cover open | The document feeder cover is open. | The ADF | |
|
| directly above the ADF feed motor. When the |
ADF
If you have recently disassembled the ADF, make sure that all of the covers have been installed correctly and make sure that the wiring to this sensor is firmly seated. Also verify that CN105 on the
Open the Troubleshooting menu, and touch Scanner Tests and then Sensors. Open and close the ADF