HP R5500 Warranty information, Limited warranty, $250,000 Computer Load Protection Guarantee

Page 50

Warranty information

In this section

 

Limited warranty

50

$250,000 Computer Load Protection Guarantee

50

Pre-Failure Battery Warranty

50

Limited warranty

 

To back up the wide range of features offered with the UPS, a 3-year limited warranty is provided.

 

$250,000 Computer Load Protection Guarantee

In addition to the limited warranty, a $250,000 Computer Load Protection Guarantee (provided by the original equipment manufacturer) is offered.

IMPORTANT: The $250,000 Computer Load Protection Guarantee is offered only in The United States and Canada.

The $250,000 Computer Load Protection Guarantee only applies if:

The UPS is plugged into a suitably grounded and wired outlet using no extension cords, adapters, other ground wires, or other electrical connections.

The UPS installation complies with all applicable electrical and safety codes specified by the NEC.

The UPS is used under normal operating conditions and users comply with all instructions and labels.

The UPS is not damaged by accident (other than a utility power transient), misuse, or abuse.

The Guarantee applies only to the original end-user and is non-transferable.

The Guarantee does not include reimbursement for or restoration of any data loss.

The UPS is either connected directly to an enterprise class PDU, which is then connected directly to a server, workstation, or personal computer, or the UPS is connected directly to a server, workstation, or personal computer.

Pre-Failure Battery Warranty

The Pre-Failure Battery Warranty, standard on all UPS units, extends the advantage of a 3-year limited warranty by applying it to the battery before it actually fails. The Pre-Failure Battery Warranty ensures that the battery is replaced free of charge when a notification that the battery might fail is received from power management software. The battery warranty coverage is 3 years for parts. The warranty for the first year of ownership includes parts and labor. If battery spares are not available for a particular UPS model, the entire UPS, including its battery, is replaced.

A Pre-Failure Battery warning is given 30 days before a battery failure. The warning is indicated in one or both of the following ways:

An LED showing the battery is low

Warranty information 50

Image 50
Contents HP UPS R5500 User Guide Audience assumptions Contents Spares Warranty information UPS front panel Component identificationUPS R5500 overview This sectionUPS front panel controls Front panel is shown with the bezel removedUPS front panel LED indicators UPS rear panel Repo portERM rear panel Preparing to install the hardware InstallationPrecautions Readying the equipment Tools and materialsSelecting a site Installing the mounting rails Installation Installing the UPS Preparing the rails for integrated shippingRemoving the UPS battery bracket Installing the batteries Replacing the UPS battery bracket Installation Connecting the Repo port Installation Connecting devices to the UPS Connecting the ground bonding cableConnecting the UPS to utility power Installation Installing the ERM Starting power to the loadInstallation Installation UPS operations Standby modeOperate mode Modes of operationAuto-Bypass mode Configuring the UPSConfigure mode Testing the LEDs Silencing an audible alarmPowering down the UPS Verifying the Repo port connectionPower management Power management softwareMaintenance Removing the UPS front bezelMaintenance Replacing the UPS option card Replacing the batteries Important battery safety informationBattery care and storage guidelines UPS battery replacement procedure Replacing the UPSReplacing the ERM Updating the UPS firmware Troubleshooting LED and audible alarm troubleshootingBattery condition Bypass is out of rangeInput voltage is out of range General alarm conditionInternal UPS fault condition Insufficient warning of low batteriesUPS does not provide the expected backup time Low battery shutdownsSite wiring condition Overload conditionUPS is on battery UPS frequently switches between utility and battery powerUPS is in Auto-Bypass mode Utility power conditionERM physical specifications SpecificationsUPS physical specifications UPS input specificationsVoltage specifications UPS output specificationsPower protection specifications Battery runtime for Intl model Battery specificationsBattery runtime for NA/JPN model Output tolerance specificationsEnvironmental specifications Repo port specificationsOrdering spares UPS spare parts listSpares Hardware options HP contact information Technical supportBefore you contact HP $250,000 Computer Load Protection Guarantee Warranty informationLimited warranty Pre-Failure Battery WarrantyNotification from power management software Federal Communications Commission notice Regulatory compliance noticesRegulatory compliance identification numbers FCC rating labelClass a equipment Class B equipmentCanadian notice Avis Canadien ModificationsCables European Union regulatory noticeJapanese notice Bsmi notice Battery replacement notice Taiwan battery recycling notice Power cord statement for JapanGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Acronyms and abbreviations Index On button, location Operate mode Index
Related manuals