SPX Cooling Technologies 7014H081 - 7014K121 Marley / MC Fluid Cooler / Engineering Data Hoisting

Page 12

Marley / MC Fluid Cooler / Engineering Data : Hoisting

12

B

80°MAX

A

D

C

 

 

Lower Module

 

 

Upper Module

 

Model

 

 

 

 

 

 

 

 

A

B

 

Weight

C

D

 

Weight

 

 

 

 

 

kg

 

kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7012

1422

1143

 

435

1600

1143

 

1320

 

 

 

 

 

 

 

 

 

7013

2337

1143

 

549

2515

1143

 

1740

 

 

 

 

 

 

 

 

 

7014

3302

1143

 

699

3429

1143

 

2175

 

 

 

 

 

 

 

 

 

7054

1245

2057

 

1186

3327

2438

 

3942

 

 

 

 

 

 

 

 

 

7055

3073

2057

 

1640

1753

2438

 

5450

 

 

 

 

 

 

 

 

 

7073

2515

2794

 

1610

2515

2794

 

3996

 

 

 

 

 

 

 

 

 

7074

1295

2642

 

2071

3531

2794

 

4908

 

 

 

 

 

 

 

 

 

7075

2743

2642

 

2905

5207

2794

 

6545

 

 

 

 

 

 

 

 

 

NOTE

1Hoisting operations can be dangerous and suitable safety precautions should be taken to protect personnel and the equipment being hoisted.

2All hoisting equipment should be certified and comply with local and national safety regulations.

3Ensure that slings are of sufficient length so not to impose bending loads onto the casing—use of spreader bars is essential.

4For overhead lifts or where additional safety is required, add slings beneath the fluid cooler unit.

Image 12
Contents Marley MC Fluid Cooler Marley / MC Fluid Cooler / Table of Contents Marley / MC Fluid Cooler Marley / MC Fluid Cooler Marley / MC Fluid Cooler / Engineering Data Schematic Side Elevation7014H101 7014J101 3061 1041 3098 2587 1887 7014K101 Inlets 7055P081 15 x 7055Q081 4172 813 18.6 x Inlets Outlets Access Section Marley / MC Fluid Cooler / Engineering Data Support ModelMarley / MC Fluid Cooler / Engineering Data Hoisting 80MAXAIR Inlet Elevation Fluid Cooler Coil Fluid Cooling Recirculating WaterElectric Basin Heaters Indoor Storage TankMarley / MC Fluid Cooler / Engineering Data Water Quality BlowdownWater Treatment Marley / MC Fluid Cooler / Specifications Base Performance WarrantyBase Thermal PerformanceCoil Design LoadingConstruction Mechanical Equipment Access WarrantyDrift Eliminators Hot Water Distribution SystemMarley / MC Fluid Cooler / Specifications Options Stainless Steel Options Stainless Steel Collection BasinAll Stainless Fluid cooler Convenience and Safety Options Top Access Platform Ladder Safety CageLadder Extension Access Door Platform Distribution System Access Door PlatformControl Options Control System Vibration Limit Switch Basin HeaterMarley Premium VFD System Marley / MC Fluid Cooler / Specifications Options Miscellaneous Options Sound Control Discharge Hood Gregorys Bank Worcester WR3 8AB United Kingdom