Toshiba RAV-SP240AT2-UL installation manual Dimension

Page 3

Outdoor Unit

Installation Manual

1 DIMENSION

0.7"(17.5)

5.0"(128)

14.4"(365)

4.7"(118)

0.7"(17.5)

2.9"(74)

5-drain hole 0.8"(20) ~

burring hole

15.0"(380)

 

7.9"(200)

2.4"(60)

 

Air inlet

 

 

 

port

 

 

Air inlet

1.8"(46)

1.3"(34)

6.7"(170)

port

 

 

 

 

3.0"(75)

 

 

Air outlet

port

A legs

15.1"(383)

2.8"(70)

5.9"(150)

23.6"(600)

3.5"(88)

Drain hole

( 1.0"(25) burring hole)

B legs

1.9"(48)

2.1"(54)

1.5"(39)

3.8"(96)

 

0.5"(12)

1.6"(40)

Mounting bolt hole

 

(

0.5"(12)~ 0.7"(17) U-shape hole)

 

Details of B legs

1.6"(40)

Mounting bolt hole

 

(

0.5"(12) ~ 0.7"(17) long hole)

Details of A legs

 

 

 

35.4"(900)

 

Refrigerant pipe

 

 

12.6"(320)

 

2.0"(52)

21.7"(550)

 

 

 

 

 

 

 

 

connecting port

 

 

 

 

 

 

 

 

 

 

0.4"(9.5) flare

 

 

 

 

 

 

 

 

 

 

at liquid side

 

 

 

 

 

 

 

 

 

 

Refrigerant pipe

 

1.2"(30)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connecting port

 

 

 

 

 

 

 

 

 

 

0.6"(15.9) flare

 

 

 

 

 

 

 

 

 

 

at gas side

 

 

 

 

 

 

 

 

 

 

 

Conduit hole

 

 

 

22.9"(581)

21.0"(534)

 

 

 

 

 

( 0.9"(22) hole)

 

35.0"(890)

 

 

 

 

 

Refrigerant piping hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.1"(130)

2.0"(50)

 

 

 

5.8"(148)

6.5"(165)

 

 

 

 

9.7"(247)

10.0"(255)

 

 

 

 

 

2.7"(68)

20.4"(518)

7"(178)

7"(178)

Z

 

2.2"(56)

3.4"(85)

3.9"(99)

2.3"(58)

1.0"(24)

 

2.4"(60)

7"(178)

 

 

 

0.7"(18)

 

 

 

12.9"(327)

 

3.3"(83)

 

0.3"(7)

 

 

15.7"(400)

 

 

 

 

 

 

 

0.3"(7)

 

 

 

Mounting hole sold separately

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(12 -

0.1"(3) emboss)

 

 

 

 

 

 

 

 

 

 

 

 

Knockout for downward piping

 

 

2.6"(65)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z views

2.2"(55)3.7"(95)

0.5"(12)

Refrigerant piping hole

2.5"(64)

EN

– 2 –

2-EN

Image 3
Contents Installation manual Contents Dimension Accessory Parts Part name ’ty Shape Usage Installation manualHand this directly to the customer „ Piping Field supplied System RequirementsBe sure to ground the equipment Precautions for SafetyEquipment Damage Hazard Tools/equipment Use Installation of NEW Refrigerant AIR Conditioner„ Required Tools/Equipment and Precautions for Use New Refrigerant Air Conditioner Installation„ Installation Location Do not install the outdoor unit in the following locationExample Upper side is free Above unit is free „Required ClearancesUnit in mm Barrier at rear side Barrier in frontBarriers in front and back of unit „ Installation of Outdoor UnitStandard installation Installation Manual5pcs Drain nippleFlaring diameter size a Unit in mm Refrigerant PipingFlaring Projection margin in flaring B Unit in mm Rigid Clutch typeOuter diameter of copper pipe Tightening torque „ Tightening of Flare ConnectionsDo not apply refrigerant oil to the flared surface Valve at liquid sideElectrical Connections „ Field wiring„ Wiring Attach the front pipe cover with 4 screws Triple Evacuation Method Using Vacuum PumpEvacuate and Dehydrate the System Deep Vacuum MethodLiquid side Open service valvesValve handling precautions Final Tubing Check11PERIODIC Maintenance Finishing10TEST RUN Verifying Fault code status Outdoor control board 12TROUBLESHOOTINGD800 D801 D802 D803 D804 D805 14POWER Save Procedure13UNIT Pump Down EH99865401

RAV-SP240AT2-UL specifications

The Toshiba RAV-SP240AT2-UL is a state-of-the-art air conditioning unit that showcases Toshiba's commitment to energy efficiency, innovation, and comfort. Designed primarily for commercial use, it stands out as an ideal solution for businesses that require a reliable and effective climate control system.

One of the main features of the RAV-SP240AT2-UL is its powerful 24,000 BTU cooling capacity, which allows it to effectively cool larger spaces. This unit functions efficiently even in extreme weather conditions, providing optimal performance regardless of outside temperatures. The RAV-SP240AT2-UL also boasts a heating capacity, making it a versatile option for year-round climate control.

Energy efficiency is a significant characteristic of this model, as it comes equipped with an advanced inverter technology. This technology allows the unit to adjust its cooling and heating output according to the specific requirements of the space. As a result, users can expect lower energy consumption, reduced electricity bills, and a lower carbon footprint. The RAV-SP240AT2-UL has a high Energy Efficiency Ratio (EER) rating that further underscores its energy-saving capabilities.

In terms of installation, the RAV-SP240AT2-UL is designed for easy integration. Its compact size and lightweight design make it suitable for various commercial settings, including offices, retail spaces, and restaurants. The unit can be installed in both horizontal and vertical configurations, providing flexibility to meet the unique layout of any building.

The Toshiba RAV-SP240AT2-UL also includes advanced filtration systems that enhance indoor air quality. Its multi-stage air filtration process removes dust, allergens, and other particulates, ensuring a healthier environment for occupants. Additionally, the unit operates at a low noise level, providing a quiet atmosphere that enhances the comfort of any space.

Another notable technology featured in the RAV-SP240AT2-UL is the Smart Control system, which allows users to monitor and manage their air conditioning remotely. This feature adds convenience and flexibility, enabling businesses to optimize their energy use and maintain a comfortable environment, even from a distance.

Overall, the Toshiba RAV-SP240AT2-UL is a robust and efficient air conditioning solution tailored for commercial spaces. With its blend of power, energy efficiency, and advanced technology, it ensures an optimal climate control experience while promoting sustainability.