TABLE 12: HEATING CAPACITIES - 4 TON (BHP048)
CFM | RETURN | CAP1 |
|
| OUTDOOR AIR TEMPERATURE, °F (72% RH) |
|
| |||||
AIR °F | & KW |
|
|
|
|
|
|
|
|
| ||
|
| 0 | 10 | 20 | 30 | 40 | 50 | 60 | ||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| ||
| 55 | MBH | 13.911 | 17.096 | 21.021 | 25.859 | 31.821 | 39.170 | 48.226 | 59.388 | ||
| KW | 2.342 | 2.568 | 2.795 | 3.022 | 3.249 | 3.476 | 3.703 | 3.930 | |||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
1200 | 70 | MBH | 11.264 | 14.449 | 18.374 | 23.212 | 29.174 | 36.523 | 45.579 | 56.741 | ||
KW | 2.726 | 2.952 | 3.179 | 3.406 | 3.633 | 3.860 | 4.087 | 4.314 | ||||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
| 80 | MBH | 9.676 | 12.861 | 16.786 | 21.624 | 27.586 | 34.935 | 43.991 | 55.153 | ||
| KW | 3.067 | 3.293 | 3.520 | 3.747 | 3.974 | 4.201 | 4.428 | 4.655 | |||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
| 55 | MBH | 16.349 | 19.534 | 23.459 | 28.297 | 34.259 | 41.608 | 50.664 | 61.826 | ||
| KW | 2.408 | 2.634 | 2.861 | 3.088 | 3.315 | 3.542 | 3.769 | 3.996 | |||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
1600 | 70 | MBH | 13.702 | 16.887 | 20.812 | 25.650 | 31.612 | 38.961 | 48.017 | 59.179 | ||
KW | 2.792 | 3.018 | 3.245 | 3.472 | 3.699 | 3.926 | 4.153 | 4.380 | ||||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
| 80 | MBH | 12.114 | 15.299 | 19.224 | 24.062 | 30.024 | 37.373 | 46.429 | 57.591 | ||
| KW | 3.133 | 3.359 | 3.586 | 3.813 | 4.040 | 4.267 | 4.494 | 4.721 | |||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
| 55 | MBH | 17.629 | 20.814 | 24.739 | 29.577 | 35.539 | 42.888 | 51.944 | 63.106 | ||
| KW | 2.502 | 2.728 | 2.955 | 3.182 | 3.409 | 3.636 | 3.863 | 4.090 | |||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
2000 | 70 | MBH | 14.982 | 18.167 | 22.092 | 26.930 | 32.892 | 40.241 | 49.297 | 60.459 | ||
KW | 2.886 | 3.112 | 3.339 | 3.566 | 3.793 | 4.020 | 4.247 | 4.474 | ||||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
| 80 | MBH | 13.394 | 16.579 | 20.504 | 25.342 | 31.304 | 38.653 | 47.709 | 58.871 | ||
| KW | 3.227 | 3.453 | 3.680 | 3.907 | 4.134 | 4.361 | 4.588 | 4.815 | |||
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
1.These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have been added.
Unitary Products Group | 13 |